Statement Of Problem: Although polyetheretherketone (PEEK) and zirconia (Zir) have been used as implant-supported prosthesis (ISP) frameworks, the long-term effects of thermomechanical aging on the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with titanium (Ti) bases for patients with a partially edentulous arch are not clear.
Purpose: The purpose of this in vitro study was to determine the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with Ti bases and Ti ISP frameworks for partially edentulous arches after aging.
Material And Methods: A total of 30 ISP epoxy resin casts were obtained from a typodont with 1 straight implant (Nobel Biocare) in the mandibular right canine region and 1 implant with a 30-degree distal tilt in the mandibular right first molar region.