Significance: Anemia is a common problem in preterm neonates, and red blood cell transfusion (RBCT) is used to improve oxygen delivery. However, RBCT is associated with complications, although an increase in cerebral oxygenation has been documented, and no universally accepted biomarker for the need for transfusion (i.e.
View Article and Find Full Text PDFThyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound.
View Article and Find Full Text PDF[This corrects the article on p. 5994 in vol. 14, PMID: 38021143.
View Article and Find Full Text PDFThe detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a robust and quantitative evaluation. This paper describes a protocol to evaluate these impairments using a hybrid near-infrared diffuse optical device.
View Article and Find Full Text PDFPhysiol Meas
December 2023
In this paper, we present a detailedcharacterization of the optical and hemodynamic properties of the human sternocleidomastoid muscle (SCM), obtained through ultrasound-guided near-infrared time-domain and diffuse correlation spectroscopies.A total of sixty-five subjects (forty-nine females, sixteen males) among healthy volunteers and thyroid nodule patients have been recruited for the study. Their SCM hemodynamic (oxy-, deoxy- and total hemoglobin concentrations, blood flow, blood oxygen saturation and metabolic rate of oxygen extraction) and optical properties (wavelength dependent absorption and reduced scattering coefficients) have been measured by the use of a novel hybrid device combining in a single unit time-domain near-infrared spectroscopy, diffuse correlation spectroscopy and simultaneous ultrasound imaging.
View Article and Find Full Text PDFIn this work, we used a hybrid time domain near-infrared spectroscopy (TD-NIRS) and diffuse correlation spectroscopy (DCS) device to retrieve hemoglobin and blood flow oscillations of skeletal muscle microvasculature. We focused on very low (VLF) and low-frequency (LF) oscillations ( frequency lower than 0.145 Hz), that are related to myogenic, neurogenic and endothelial activities.
View Article and Find Full Text PDFSignificance: Critically ill newborns are at risk of brain damage from cerebrovascular disturbances. A cerebral hemodynamic monitoring system would have the potential role to guide targeted intervention.
Aim: To obtain, in a population of newborn infants, simultaneous near-infrared spectroscopy (NIRS)-based estimates of cerebral tissue oxygen saturation () and blood flow during variations of carbon dioxide tension () levels within physiologic values up to moderate permissive hypercapnia, and to examine if the derived estimate of metabolic rate of oxygen would stay constant, during the same variations.
Significance: The optical measurement of cerebral oxygen metabolism was evaluated.
Aim: Compare optically derived cerebral signals to the electroencephalographic bispectral index (BIS) sensors to monitor propofol-induced anesthesia during surgery.
Approach: Relative cerebral metabolic rate of oxygen ( ) and blood flow (rCBF) were measured by time-resolved and diffuse correlation spectroscopies.
A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties.
View Article and Find Full Text PDFWe present the LUCA device, a multi-modal platform combining eight-wavelength near infrared time resolved spectroscopy, sixteen-channel diffuse correlation spectroscopy and a clinical ultrasound in a single device. By simultaneously measuring the tissue hemodynamics and performing ultrasound imaging, this platform aims to tackle the low specificity and sensitivity of the current thyroid cancer diagnosis techniques, improving the screening of thyroid nodules. Here, we show a detailed description of the device, components and modules.
View Article and Find Full Text PDFOver the recent years, a typical implementation of diffuse correlation spectroscopy (DCS) instrumentation has been adapted widely. However, there are no detailed and accepted recipes for designing such instrumentation to meet pre-defined signal-to-noise ratio (SNR) and precision targets. These require specific attention due to the subtleties of the DCS signals.
View Article and Find Full Text PDFIntracranial pressure (ICP) is an important parameter to monitor in several neuropathologies. However, because current clinically accepted methods are invasive, its monitoring is limited to patients in critical conditions. On the other hand, there are other less critical conditions for which ICP monitoring could still be useful; therefore, there is a need to develop non-invasive methods.
View Article and Find Full Text PDFDiffuse correlation spectroscopy (DCS) can non-invasively and continuously asses regional cerebral blood flow (rCBF) at the cot-side by measuring a blood flow index (BFI) in non-traditional units of cm/s. We have validated DCS against positron emission tomography using O-labeled water (O-water PET) in a piglet model allowing us to derive a conversion formula for BFI to rCBF in conventional units (ml/100g/min). Neonatal piglets were continuously monitored by the BabyLux device integrating DCS and time resolved near infrared spectroscopy (TRS) while acquiring O-water PET scans at baseline, after injection of acetazolamide and during induced hypoxic episodes.
View Article and Find Full Text PDFWe have investigated the accuracy and precision of "the BabyLux device", a hybrid time-resolved near-infrared (TRS) and diffuse correlation spectroscopy (DCS) neuro-monitor for the pre-term infant. Numerical data with realistic noise were simulated and analyzed using the BabyLux device as a reference system and different experimental and analysis parameters. The results describe the limits for the precision and the accuracy to be expected.
View Article and Find Full Text PDFThe BabyLux device is a hybrid diffuse optical neuromonitor that has been developed and built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring of microvascular cerebral blood flow and blood oxygenation. It integrates time-resolved near-infrared and diffuse correlation spectroscopies in a user-friendly device as a prototype for a future medical grade device. We present a thorough characterization of the device performance using test measurements in laboratory settings.
View Article and Find Full Text PDFArch Dis Child Fetal Neonatal Ed
November 2019
Objectives: A new device that combines, for the first time, two photonic technologies (time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy) was provided and tested within the BabyLux project. Aim was to validate the expected changes in cerebral oxygenation and blood flow.
Methods: A pulse oximeter and the BabyLux device were held in place (right hand/wrist and frontoparietal region, respectively) for 10 min after birth in healthy term infants delivered by elective caesarean section.
The in vivo optical and hemodynamic properties of the healthy (n = 22) and pathological (n = 2) human thyroid tissue were measured non-invasively using a custom time-resolved spectroscopy (TRS) and diffuse correlation spectroscopy (DCS) system. Medical ultrasound was used to guide the placement of the hand-held hybrid optical probe. TRS measured the absorption and reduced scattering coefficients (μa, μs') at three wavelengths (690, 785 and 830 nm) to derive total hemoglobin concentration (THC) and oxygen saturation (StO2).
View Article and Find Full Text PDFWe present a new hardware simulator (HS) for characterization, testing and benchmarking of digital correlators used in various optical correlation spectroscopy experiments where the photon statistics is Gaussian and the corresponding time correlation function can have any arbitrary shape. Starting from the HS developed in [Rev. Sci.
View Article and Find Full Text PDFThe abnormal, uncontrolled production of blood cells in the bone marrow causes hematological malignancies which are common and tend to have a poor prognosis. These types of cancers may alter the hemodynamics of bone marrow. Therefore, noninvasive methods that measure the hemodynamics in the bone marrow have a potential impact on the earlier diagnosis, more accurate prognosis, and in treatment monitoring.
View Article and Find Full Text PDF