Since the advent of super-resolution microscopy, countless approaches and studies have been published contributing significantly to our understanding of cellular processes. With the aid of chromatin-specific fluorescence labeling techniques, we are gaining increasing insight into gene regulation and chromatin organization. Combined with super-resolution imaging and data analysis, these labeling techniques enable direct assessment not only of chromatin interactions but also of the function of specific chromatin conformational states.
View Article and Find Full Text PDFNuclear texture analysis is a well-established method of cellular pathology. It is hampered, however, by the limits of conventional light microscopy (ca. 200 nm).
View Article and Find Full Text PDFDuring meiosis, homologous chromosomes associate to form the synaptonemal complex (SC), a structure essential for fertility. Information about the epigenetic features of chromatin within this structure at the level of superresolution microscopy is largely lacking. We combined single-molecule localization microscopy (SMLM) with quantitative analytical methods to describe the epigenetic landscape of meiotic chromosomes at the pachytene stage in mouse oocytes.
View Article and Find Full Text PDFHigher order chromatin structure is not only required to compact and spatially arrange long chromatids within a nucleus, but have also important functional roles, including control of gene expression and DNA processing. However, studies of chromatin nanostructures cannot be performed using conventional widefield and confocal microscopy because of the limited optical resolution. Various methods of superresolution microscopy have been described to overcome this difficulty, like structured illumination and single molecule localization microscopy.
View Article and Find Full Text PDFIEEE Trans Med Imaging
July 2012
In in vivo optical projection tomography (OPT), object motion will significantly reduce the quality and resolution of the reconstructed image. Based on the well-known Helgason-Ludwig consistency condition (HLCC), we propose a novel method for motion correction in OPT under parallel beam illumination. The method estimates object motion from projection data directly and does not require any other additional information, which results in a straightforward implementation.
View Article and Find Full Text PDFWe describe a versatile optical projection tomography system for rapid three-dimensional imaging of microscopic specimens in vivo. Our tomographic setup eliminates the in xy and z strongly asymmetric resolution, resulting from optical sectioning in conventional confocal microscopy. It allows for robust, high resolution fluorescence as well as absorption imaging of live transparent invertebrate animals such as C.
View Article and Find Full Text PDFOptical projection tomography (OPT) is a noninvasive imaging technique that enables imaging of small specimens (<1 cm), such as organs or animals in early developmental stages. In this paper, we present a set of computational methods that can be applied to the acquired data sets in order to correct for (a) unknown background or illumination intensity distributions over the field of view, (b) intensity spikes in single CCD pixels (so-called "hot pixels"), and (c) refractive index mismatch between the media in which the specimens are embedded and the environment. We have tested these correction methods using a variety of samples and present results obtained from Parhyale hawaiensis embedded in glycerol and in sea water.
View Article and Find Full Text PDFThe application of optical projection tomography to in-vivo experiments is limited by specimen movement during the acquisition. We present a set of mathematical correction methods applied to the acquired data stacks to correct for movement in both directions of the image plane. These methods have been applied to correct experimental data taken from in-vivo optical projection tomography experiments in Caenorhabditis elegans.
View Article and Find Full Text PDFMethods Mol Biol
September 2010
In this chapter we present the method of spatially modulated illumination (SMI) microscopy, a (far-field) fluorescence microscopy technique featuring structured illumination obtained via a standing wave field laser excitation pattern. While this method does not provide higher optical resolution, it has been proven a highly valuable tool to access structural parameters of fluorescently labeled macromolecular structures in cells. SMI microscopy has been used to measure relative positions with a reproducibility of <2 nm between fluorescing objects.
View Article and Find Full Text PDFWe describe the usage of the spatially modulated illumination (SMI) microscope to estimate the sizes (and/or positions) of fluorescently labeled cellular nanostructures, including a brief introduction to the instrument and its handling. The principle setup of the SMI microscope will be introduced to explain the measures necessary for a successful nanostructure analysis, before the steps for sample preparation, data acquisition and evaluation are given. The protocol starts with cells already attached to the cover glass.
View Article and Find Full Text PDF