Publications by authors named "U Rapp-Bernhardt"

Objective: We sought to evaluate the diagnostic performance of a portable indirect flat-panel detector for low-dose imaging as compared with an asymmetric film-screen system in a pediatric intensive care unit.

Materials And Methods: A total of 120 neonates underwent chest radiographs using a portable flat-panel detector (digital speed 800) and an asymmetric film-screen system (400 speed). Four readers evaluated the detection of 11 anatomic and 5 pathologic landmarks and 4 support devices.

View Article and Find Full Text PDF

Purpose: To compare the exposure dose requirements and performance of a portable indirect flat-panel detector for pediatric use in the depiction of catheters, simulated pulmonary nodules, and simulated interstitial lung disease with those of storage phosphor radiography.

Materials And Methods: Catheters and simulated nodules and subtle interstitial lung disease (miliary, reticular, linear, and ground-glass patterns) were superimposed over an anthropomorphic chest phantom. Images were obtained with different exposures corresponding to simulated speeds of 400 and 800 with a portable flat-panel detector and printed on hard copies.

View Article and Find Full Text PDF

Purpose: To compare three tube voltages in digital selenium radiography for the detection of simulated interstitial lung disease, nodules, and catheters.

Materials And Methods: Simulated catheters, nodules, and ground-glass, linear, miliary, and reticular patterns were superimposed over an anthropomorphic chest phantom. Digital selenium radiography was performed with different tube voltages (70, 90, and 150 kVp).

View Article and Find Full Text PDF

Rationale And Objectives: To evaluate a large area, cesium iodide amorphous silicon flat-panel detector (CsI/a-Si) at 3 tube voltages to detect simulated interstitial lung disease, nodules, and catheters.

Methods: Simulated interstitial lung disease, nodules, and catheters were superimposed over a chest phantom. Images were generated at 125 kVp, 90 kVp, and 70 kVp at the same surface dose and reduced effective dose equivalent for 90 kVp and 70 kVp and printed on hard copies.

View Article and Find Full Text PDF

Purpose: Virtual cystoscopy at different mAs settings in patients with tumors of the bladder in comparison with cystoscopy and axial CT.

Materials And Methods: The study included 28 patients with bladder tumors and 28 patients without tumors as control group. The bladder was distended with air and scanned at two different mAs settings (protocol 1 and 2).

View Article and Find Full Text PDF