Backgrounds: This study aimed to compare the effects of different energy drinks on the surface roughness, weight loss, and color change of various bioactive restorative materials.
Methods: Charisma Diamond One, Activa™ BioActive Restorative, Activa™ Presto™ and Equia Forte HT Fil samples were prepared using plastic molds (8 × 2 mm) (n = 10/groups). After polishing, the samples were weighed, their colors were recorded using a spectrophotometer according to the CIEDE2000 system, and their surface roughness was measured using a profilometer.
Understanding that dental carious lesions occur as a result of the action of micro-organisms in the dental plaque biofilm, where demineralisation on the tooth surface is the first sign of the disease, such incipient lesions can be treated using preventive, non-operative and minimally invasive operative dentistry. If the caries process is left unmanaged, the lesions progress towards cavitation, leading to more invasive treatments. This article discusses the principles of preventive, non-invasive and micro-invasive treatments of early carious lesions, outlining the clinical situations where these therapies can be applied.
View Article and Find Full Text PDFObjective: To evaluate the 5-year clinical performance of a glass hybrid restorative system and a nano-hybrid resin composite in moderate to large two-surface class II cavities.
Materials And Methods: This study was carried out by dental schools in Zagreb, Croatia; Izmir, Turkey; Belgrade, Serbia; and Milan, Italy. A total of 180 patients requiring two class-II two-surface restorations in the molars of the same jaw were recruited.
Background: The objective was to investigate the radiopacity of 11 commercial posterior restorative materials by establishing their mean gray values (MGVs) and comparing them with dental hard tissues.
Methods And Materials: Five-disc specimens were prepared for each of the following materials: Cerasmart 270 CAD/CAM block A3LT (CS), Amalgam (A), Ketac Molar A3 (KM), Cention-N A2 (CN), G-aenial Universal Flo AO2 (GO2) and A2 (G2), Ever-X Flow Dentine (EXD) and Bulk (EXB) shades, Equia Forte HT Fil A2 (EF2) and A3 (EF3), and Equia Fil A3 (E3). Freshly extracted maxillary premolar teeth were used as a control.
The aim of the present study is to evaluate the physical properties of endodontically treated teeth restored with five different restorative techniques and materials. Hundred and forty extracted human molar teeth were used. In addition to five restoration groups, specimens with no restorations were used as the negative control, and intact molar teeth were used as the positive control.
View Article and Find Full Text PDFThe contemporary approach for operative caries management emphasizes personalized interventions for each patient, dependent upon the individual's caries susceptibility/risk, the stage of the carious lesion and its activity. The clinician's challenge is to optimize the extent of cavity preparation and the choice of dental restorative biomaterials, appreciating the benefits offered by ion-releasing restorative materials. There is a growing application of bioactive/bio-interactive materials in minimally invasive operative dentistry, as they may help with tissue recovery by ion release.
View Article and Find Full Text PDFBackground: Wear and quality assessments of translucent monolithic zirconia and CAD-on restorations were performed.
Methods: Forty 3-unit posterior fixed partial denture (FPD) in 18 patients (age:18-50 years) were made from translucent monolithic zirconia (tm) (Zenostar T) and zirconia-frameworked, lithium disilicate layered (c) (CAD-on), materials in a split-mouth design. Restorations were digitally fabricated and their internal and marginal adaptations were measured before cementation followed by luting (Multilink Speed).
Objectives: We assessed the long-term cost-effectiveness of glass hybrid (GH) versus composite (CO) for restoring permanent molars using a health economic modelling approach.
Methods: A multi-national (Croatia, Serbia, Italy, Turkey) split-mouth randomized trial comparing GH and CO in occlusal-proximal two-surfaced cavities in permanent molars (n=180/360 patients/molars) provided data on restoration failure and allocation probabilities (i.e.
Objectives: We assessed the cost-effectiveness of two amalgam alternatives, glass hybrid (GH) and composite (CO) in a multi-country randomized controlled split-mouth trial.
Materials: University clinics in Croatia, Serbia, Italy and Turkey participated. Pairs of GH (EQUIA Forte, GC) and a nano-hybrid CO (TetricEvoCeram, IvoclarVivadent) were randomly placed in occlusal-proximal two-surfaced cavities in permanent molars of adults (n = 180/360 patients/molars).
Purpose: To compare the clinical performance of a glass hybrid restorative system, EQUIA Forte, with that of a nanohybrid resin composite, Tetric EvoCeram, in two-surface class II cavities.
Materials And Methods: This multicenter, randomized controlled clinical study was conducted at four different dental schools. In total, 360 restorations were placed in patients in need of two class-II, two-surface restorations in the molar region of the same jaw.
Determining the energy transferred at the bottom of eleven bulk-fill resin composites, comparing top and bottom microhardness's and evaluating the correlation between microhardness and radiant energy were aimed. Samples were placed over the bottom sensor of a visible light transmission spectrophotometer and polymerized for 20 s. The bottom and top Knoop microhardness were measured.
View Article and Find Full Text PDFThe aim of this study was to evaluate the intrapulpal temperature changes during the curing of different bulk-fill restorative materials. Ten mandibular molar teeth were selected and occlusal surfaces were removed to obtain a standard 0.5 mm occlusal dentin thickness.
View Article and Find Full Text PDFObjective: The aim of this study was to evaluate the long-term clinical performance of two encapsulated glass ionomer cements (GICs) (EquiaFil and Riva SC) covered with two different coatings (Equia Coat and Fuji Varnish) over six years using modified US Public Health Service (USPHS) criteria.
Methods: Fifty-four patients having class I and II restorations/caries were included in the study. A total of 256 restorations were made with EquiaFil and Riva SC.
J Esthet Restor Dent
February 2017
Objectives: The aim of this study was to evaluate the effects of various finishing and polishing systems on the final surface roughness of a resin composite. Hypotheses tested were: (1) reduced-step polishing systems are as effective as multiple-step systems on reducing the surface roughness of a resin composite and (2) the number of application steps in an F/P system has no effect on reducing surface roughness.
Materials And Methods: Ninety discs of a nano-hybrid resin composite were fabricated and divided into nine groups (n = 10).
Objectives: The aim of this study was to evaluate the effect of resin coating on the wear depth of highly viscous glass ionomer cements (HVGICs) after 40,000 cycles, corresponding to over 8 years of tooth brushing.
Materials And Methods: A resin composite (Gradia Direct Posterior), two HVGICs (EQUIA Fil and Riva Self Cure), a resin coating (EQUIA Coat) and a conventional varnish (Fuji Varnish) were used in the study. The control groups were the resin composite group and the non-coated HVGICs groups.
Unlabelled: The aims of this study were to: (1) evaluate the A2 shades of various types and brands of resin composites to determine if any color differences occurred before and after polymerization and after 1 month of storage in water and (2) examine the correlation among the color changes and changes in Commission internationale de l'éclairage L*, a*, and b* values after polymerization and after 1 month of storage in water. One submicron-hybrid (Spectrum TPH3, DENTSPLY DeTrey, Milford, DE, USA), one nano-filled (Filtek Supreme XT, 3 M ESPE, St. Paul, MN, USA), three micro-hybrid (Filtek Z250, 3 M ESPE; Esthet X, DENTSPLY DeTrey; and Gradia Direct, GC, Tokyo, Japan), and five nano-hybrid (Ceram X, DENTSPLY DeTrey; Clearfil Majesty Esthetics, Kuraray, Osaka, Japan; Premise, Kerr Corporation, Orange, CA, USA; Tetric Evo Ceram, Ivoclar Vivadent, Schaan, Liechtenstein and Tetric N Ceram, Ivoclar Vivadent) light-curing resin composites were tested.
View Article and Find Full Text PDFPurpose: To evaluate the effect of different surface treatments and bonding procedures on the tensile bond strength (TBS) of resin composites repaired 6 months after polymerization.
Materials And Methods: Resin composite sticks were aged in distilled water at 37°C for 6 months. They were divided into 12 groups (n = 10) according to the combination of surface treatment/bonding procedures [none, only bur treatment, XP Bond (XPB/Dentsply/DeTrey) with/without bur, AdheSE (A-SE/Ivoclar/Vivadent) with/without bur, Composite Primer (CP/GC) with/without bur, CP after bur and acid-etching, XPB after acid etching and CP with bur, A-SE after bur and CP].
Objective: This study investigated the radiopacity of six commercially available flowable composites by using a digital image analysis method to determine the mean gray values of the materials.
Methods: The flowable resin composites evaluated in this study were Clearfil Majesty Flow, Estelite Flow Q, Tetric N Flow, Esthet X Flow, Filtek Supreme XT Flow and Gradia Direct LoFlo. Ten sample discs (6 x 1 mm) for each group were prepared and 1-mm thick slices were obtained from freshly-extracted teeth for the control group.
Purpose: The effect of three different bonding strategies on the shear bond strength of a resin composite to fluorotic enamel surfaces was investigated.
Materials And Methods: Thirty-six noncarious extracted human molars with fluorosis and 36 without fluorosis were scraped clean from any remaining tissue, and then were divided into three subgroups according to the tested dentin bonding systems. The resin composite was bonded to the teeth using three different adhesive systems: Peak LC Bond with an etch-and-rinse technique (Ultradent Products), Peak LC Bond with a self-etching technique using Peak SE Primer (Ultradent Products), and Xeno V (Dentsply Caulk) using a one-bottle self-etching technique.
Purpose: The purpose of this study was to compare the clinical performance of a polyacid modified resin composite and a nanocomposite applied with an antibacterial adhesive system over a period of 2 years in noncarious Class V lesions.
Materials And Methods: Twenty-four patients with at least two noncarious cervical lesions were enrolled in the study. The teeth were restored with a polyacid modified resin composite (Dyract eXtra, Dentsply DeTrey) or a nanocomposite (Filtek Supreme, 3M/ESPE).
This study determined the compositional changes and microhardness of the cavity floor prepared by Er,Cr:YSGG and Er:YAG lasers and compared the results with the conventional method of bur preparation. Fifteen non-carious human molars were used in this study. On the buccal and lingual surfaces of each tooth, two cavities (mesio-distal 3 mm, inciso-gingival 3 mm, depth 2 mm) were prepared with two different laser devices (Er,Cr:YSGG laser; Waterlase MD and Er:YAG laser; KaVo Key Laser 3) and a high-speed turbine.
View Article and Find Full Text PDFObjective: This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution.
Methods: The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated.
Statement Of The Problem: Many regions in the world do not have electricity, water, or access to dental facilities that allows the treatment of caries with dental handpieces and rotary burs. For restorative techniques used in these regions, an antibacterial self-adherent glass ionomer material would contribute considerably.
Purpose: This study aimed to test if chlorhexidine diacetate (Fluka BioChemika, Buchs, Switzerland)- or chlorhexidine digluconate (Sigma-Aldrich, Steinheim, Germany)-added ChemFil Superior glass ionomer cement (Dentsply DeTrey, Konstanz, Germany) had any long-term antibacterial effect against certain oral bacteria and to test the new formulation's physical properties.