Publications by authors named "Tuijthof G"

Purpose: To (1) investigate the hypothesis that there is high variability in the reported methods to derive axes and joint orientations from three-dimensional (3D) bone models to (a) perform 3D knee-related leg alignment analysis and (b) define coordinate systems for the femur, tibia and leg and (2) identify underlying principles that might lead to agreement on a universal 3D leg alignment analysis framework.

Methods: A systematic review of the literature between January 2006 and June 2024 was performed. Articles explicitly reporting methods to derive axes and joint orientations from CT-based 3D bone models for alignment parameters and/or coordinate systems of the femur, tibia and leg were included.

View Article and Find Full Text PDF
Article Synopsis
  • - Sacroiliac joint fusion (SIJF) is a minimally invasive procedure for treating sacroiliac dysfunction, and precise implant positioning is critical to prevent nerve damage.
  • - The study investigates the feasibility of superimposing virtual surgical planning (VSP) onto real-time fluoroscopic images during surgery to improve accuracy in implant placement.
  • - Results from five procedures showed that the intraoperative guidance method effectively minimized deviation from the VSP, with only minor complications, indicating a promising alternative to more invasive navigation systems.
View Article and Find Full Text PDF

Background: A corrective radius osteotomy is often performed in patients with a symptomatic distal radius malunion. In 3D-planned osteotomies, the unaffected radius is mirrored over the malunited radius after adjusting for left-right length differences using both ulnae. This approach assumes that ulnar length differences in a malunion population are similar to those in a healthy population.

View Article and Find Full Text PDF

Purpose: To investigate the simultaneous effect of 3-dimensional (3D) hinge axis (HA) orientation on alignment parameters in all 3 anatomical planes in high tibial osteotomy.

Methods: A computed tomography-based 3D model of a human tibia/fibula was used to establish a 3D tibial coordinate system based on the tibial mechanical axis. In here, an HA was positioned and an opening-wedge high tibial osteotomy with a rotation angle of 10° over the HA was simulated.

View Article and Find Full Text PDF

Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients.

View Article and Find Full Text PDF

The incidence of osteoarthritis (OA) has been expected to increase due to an aging population, as well as an increased incidence of intra-articular (osteo-) chondral damage. Lipids have already been shown to be involved in the inflammatory process of OA. This study aims at revealing region-specific lipid profiles of the infrapatellar fat pad (IPFP) of OA or cartilage defect patients by matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), which could be used as biomarkers for early OA detection.

View Article and Find Full Text PDF

Purpose: To interpret the Medical Device Regulation for occupational therapists in the Netherlands involved in prescribing and manufacturing custom-made assistive devices and to develop a roadmap for implementation.

Materials And Methods: Four online iterative co-design workshops were organized under supervision of a senior quality manager to assist in the interpretation of the MDR framework with a focus on custom-made assistive devices; and to assist the implementation by generating guidelines and forms. The workshops for seven participating occupational therapists had an interactive character with Q&A, small and homework assignments, and oral evaluations.

View Article and Find Full Text PDF

Background: In vivo diffuse reflectance spectroscopy provides additional contrast in discriminating nerves embedded in adipose tissue during surgery. However, large datasets are required to achieve clinically acceptable classification levels. This study assesses the spectral similarity between ex vivo porcine and in vivo human spectral data of nerve and adipose tissue, as porcine tissue could contribute to generate large datasets.

View Article and Find Full Text PDF

Mass spectrometry imaging (MSI) is a powerful technique enabling the visualization of the spatial distribution of different molecules in tissue biopsies with different pathologies. Sample handling and preparing adipose tissue for MSI is challenging and prone to molecular delocalization due to tissue melting. In this work, we developed a method for matrix-assisted laser desorption/ionization (MALDI)-MSI to study lipids in human infrapatellar fat pad (IPFP), a biomarker source in musculoskeletal pathologies, while preserving molecular spatial distribution.

View Article and Find Full Text PDF

For knee osteoarthritis and related conditions, analysis of biomarkers hold promise to improve early diagnosis and/or offer patient-specific treatment. To compare biomarker analyses, reliable, high-quality biopsies are needed. The aim of this work is to summarize the literature on the current best practices of biopsy of the synovium and synovial fluid arthrocentesis.

View Article and Find Full Text PDF

Background: The objective consisted of 2 elements, primarily to define 2 bone geometry variations of the ankle that may be of prognostic value on ankle instability and secondly to translate these bone variations from a 3D model to a simple 2D radiographic measurement for clinical use.

Methods: The 3D tibial and talar shape differences derived from earlier studies were translated to two 2D radiographic parameters: the medial malleolar height angle (MMHA) and talar convexity angle (TCA) respectively to ensure clinical use. To assess validity, the MMHA and TCA were measured on 3D polygons derived from lower leg computed tomographic (CT) scans and 2D digitally reconstructed radiographs (DRRs) of these polygons.

View Article and Find Full Text PDF

The analysis of samples with large height variations remains a challenge for mass spectrometry imaging (MSI), despite many technological advantages. Ambient sampling and ionization MS techniques allow for the molecular analysis of sample surfaces with height variations, but most techniques lack MSI capabilities. We developed a 3D MS scanner for the automated sampling and imaging of a 3D surface with laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS).

View Article and Find Full Text PDF

Introduction: Knee osteoarthritis (OA) is a joint disease, affecting multiple tissues in the joint. Early detection and intervention may delay OA development and avoid total knee arthroplasty. Specific biomarker profiles for early detection and guiding clinical decision-making of OA have not yet been identified.

View Article and Find Full Text PDF

Objective: To evaluate the size and depth of linear lesions by in vitro testing with a custom-made radio frequency biparietal bipolar ablation catheter in a single-stage setting.

Methods: A custom-made catheter was created to generate linear lesions around the left atrium and pulmonary veins of an ex vivo pig. Two frames were made, 1 epicardial and 1 endocardial.

View Article and Find Full Text PDF

Purpose: Ulnar nerve injury is the most common neurologic complication of elbow arthroscopy. The purpose of this cadaveric study was to quantify the ability of surgeons to locate the ulnar nerve behind the posteromedial capsule during elbow arthroscopy using sole arthroscopic vision.

Methods: Twenty-one surgeons were asked to pin the ulnar nerve at the medial gutter and the posteromedial compartment using arthroscopic visualization of the medial capsule only.

View Article and Find Full Text PDF

Objectives: Reconstruction plates, used to bridge segmental defects of the mandible after tumor resection or traumatic bone tissue loss, are subjected to repeated stresses of mastication. High stress concentrations in these plates can result in hardware failure. Topology optimization (TO) could reduce the peak stress by computing the most optimal material distribution in a patient-specific implant (PSI) used for mandibular reconstruction.

View Article and Find Full Text PDF

Objective: Surgical microfracture is considered a first-line treatment for talar osteochondral defects. However, current rigid awls and drills limit access to all locations in human joints and increase risk of heat necrosis of bone. Using a flexible water jet instrument to drill holes can improve the reachability of the defect without inducing thermal damage.

View Article and Find Full Text PDF

Purpose: To determine the face and construct validity as well as educational value and user-friendliness of the Simendo knee arthroscopy virtual reality simulator.

Methods: Sixty participants were recruited and equally divided into novices (0 arthroscopic procedures), intermediates (1-59 arthroscopic procedures), and experts (60 or more arthroscopic procedures). Participants were excluded if they had previously trained with the studied simulator.

View Article and Find Full Text PDF

Bone shapes, particularly those defining the subtalar joint (STJ), have not received much attention yet as a risk factor for developing chronic ankle instability (CAI) after sustaining a lateral ankle sprain (LAS). This study aimed to compare three-dimensional (3D) shape variations in the STJ bones within individuals with CAI and healthy controls. 3D statistical shape models (SSMs) of the STJ bones were built to describe the bone shape variations observed within a population consisting of 26 individuals with unilateral CAI and 26 healthy controls.

View Article and Find Full Text PDF

The bones forming the talocrural joint (TCJ) and subtalar joint (STJ) are often assumed to be bilaterally symmetric. Therefore, the contralateral limb (i.e.

View Article and Find Full Text PDF

Background: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation.

View Article and Find Full Text PDF

A rigid surface⁻volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system.

View Article and Find Full Text PDF

This experimental work focused on the sensor selection for the development of a needle-like instrument to treat small isolated cartilage defects with hydrogels. The aim was to identify the most accurate and sensitive imaging method to determine the location and size of defects compared to a gold standard (µCT). Only intravascular ultrasound imaging (IVUS) vs.

View Article and Find Full Text PDF

The implementation of Molecularly Imprinted Polymers (MIPs) into sensing systems has been demonstrated abundantly over the past few decades. In this article, a novel application for an MIP-based thermal sensing platform is introduced by using the sensor to characterize the drug release kinetics of a nanoporous silver-organic framework. This Ag nanoporous matrix was loaded with acetylsalicylic acid (aspirin) which was used as a model drug compound in this study.

View Article and Find Full Text PDF

In orthopaedic surgery, water jet drilling provides several advantages over classic drilling with rigid drilling bits, such as the always sharp cut, absence of thermal damage and increased manoeuvrability. Previous research showed that the heterogeneity of bone tissue can cause variation in drilling depth whilst water jet drilling. To improve control over the drilling depth, a new method is tested consisting of two water jets that collide directly below the bone surface.

View Article and Find Full Text PDF