Acta Radiol Open
December 2020
Chordoid glioma (CG) is a rare brain tumor that is known for its characteristic location in the third ventricle. A wide spectrum of radiological presentations has been described, with few common features among them. Its radiological diagnosis is mainly suggested by location.
View Article and Find Full Text PDFBackground: Monochorionic multifetal pregnancies are at increased risk of adverse perinatal outcome because of placental vascular anastomoses. We present a case of multicystic encephalomalacia and gastrointestinal injury in two surviving fetuses following single fetal death in first trimester and subsequent fetofetal transfusion syndrome in a monochorionic triplet pregnancy.
Case Presentation: A 31-year-old nulliparous woman had a spontaneous monochorionic triamniotic triplet pregnancy.
Objective: The purpose of this study is to explore the diagnostic accuracy of CT measurements in predicting syndesmosis instability of injured ankle, with correlation to operative findings.
Methods: From July 2006 to June 2013, 123 patients presented to a single tertiary hospital who received pre-operative CT for ankle fractures were retrospectively reviewed. All patients underwent open reduction and internal fixation for fractures and intra-operative syndesmosis integrity tests.
We aimed to explore the diagnostic accuracy of various mediastinal measurements in determining acute nontraumatic thoracic aortic dissection with respect to posteroanterior (PA) and anteroposterior (AP) chest radiographs, which had received little attention so far. We retrospectively reviewed 100 patients (50 PA and 50 AP chest radiographs) with confirmed acute thoracic aortic dissection and 120 patients (60 PA and 60 AP chest radiographs) with confirmed normal aorta. Those who had prior history of trauma or aortic disease were excluded.
View Article and Find Full Text PDFObject: Use of a flow-diverting device has shown promising short-term results in the management of vertebral artery (VA) dissecting aneurysms, but there is still uncertainty regarding its long-term efficacy and safety. The authors report their initial experience with respect to the potential utility and long-term clinical outcomes of using a flow-diverting device in the treatment of unruptured dissecting VA aneurysms.
Methods: The authors conducted a retrospective review of all cases of unruptured intracranial VA dissecting aneurysms treated at their institution (Tuen Mun Hospital) with a flow-diverting device.
Objective: To review the diagnostic power of various computed tomography (CT) signs in acute appendicitis, in particular those initially classified as inconclusive.
Materials And Methods: Retrospective review of 100 CT abdomen and pelvis studies with assessment of maximal luminal diameter, wall thickness and cross-sectional diameter of the appendix, periappendiceal inflammatory changes, and presence of appendicolith.
Results: All CT signs show statistically significant occurrences in acute appendicitis.