Publications by authors named "Tsutomu Inaoka"

Purpose:  The purpose of this study is to investigate the potential of deep learning (DL) techniques to enhance the image quality of low-field knee MR images, with the ultimate goal of approximating the standards of high-field knee MR imaging.

Methods: We analyzed knee MR images collected from 45 patients with knee disorders and six normal subjects using a 3T MR scanner and those collected from 25 patients with knee disorders using a 0.4T MR scanner.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility of using a deep learning (DL) model to generate fat-suppression images and detect abnormalities on knee magnetic resonance imaging (MRI) through the fat-suppression image-subtraction method.

Material And Methods: A total of 45 knee MRI studies in patients with knee disorders and 12 knee MRI studies in healthy volunteers were enrolled. The DL model was developed using 2-dimensional convolutional neural networks for generating fat-suppression images and subtracting generated fat-suppression images without any abnormal findings from those with normal/abnormal findings and detecting/classifying abnormalities on knee MRI.

View Article and Find Full Text PDF

Purpose: To evaluate the significant findings of hip periprosthetic joint infection (PJI) using metal-artifact-reduction (MAR) MRI and to compare the MRI results to other clinical markers.

Methods: The results of MRI, including two-dimensional fast-spin echo sequences with increased bandwidth and multi-acquisition variable-resonance image combination selective for hips with orthopedic implants at 1.5T (from April 2014 to November 2021), were retrospectively assessed for imaging findings and diagnostic impressions by two radiologists.

View Article and Find Full Text PDF

We have been developing protective equipment for portable radiography in neonatal intensive care units because the portable radiography's X-ray tube is in close proximity to the head of the nurse who is assisting the patient. Although our initial protective-equipment design was highly effective, there were some concerns that it obstructed the view of the patient and was difficult to handle. To overcome this problem, we have developed two new types of protective device: a narrow-type 0.

View Article and Find Full Text PDF

Portable imaging in the NICU requires the assistance of a nurse, and the nurse is in close proximity to the X-ray tube, In all, 64 percent of our nurses thought that additional protective equipment was needed. Therefore, a radiation protection device was created and its usefulness was verified. A protective equipment of 0.

View Article and Find Full Text PDF

Lowering the dose limit for the lens of the eye incorporated into the Regulation on Prevention of Ionizing Radiation Hazards, effective on April 2021, and dose reduction will become more and more important in the field of radiation. Radiation protective cloth is used as a protective equipment in fluoroscopy rooms. Although it is usually used to protect staff from radiation exposure during endoscopic retrograde cholangiopancreatography, we investigated whether there is a way to use it for procedures in clean areas.

View Article and Find Full Text PDF

Materials And Methods: Magnetic resonance imaging around metal joint prostheses including multiacquisition variable-resonance image combination selective at 1.5 T (from April 2014 to August 2020) was retrospectively evaluated by 2 radiologists for detection of abnormal findings (joint effusion, capsular thickening, pericapsular edema, soft-tissue fluid collection, soft-tissue edema, bone marrow edema pattern around the implant [BME pattern], lymphadenopathy, and others) and overall image impression for PJI. Regarding the soft-tissue fluid collection, presence of communication to the joint or capsular-like structure was evaluated.

View Article and Find Full Text PDF

The bone mineral density (BMD) measurement of the lumbar spine with dual-energy X-ray absorptiometry (DXA) has the advantage of being able to detect early changes in BMD, which is usually used for the evaluation of drug therapy. However, DXA is not considered suitable for spinal deformity because it is a two-dimensional measurement. The aims of this study were to compare frontal and lateral measurements with a phantom and to examine the possibility of the evaluation of lumbar spine BMD in spinal deformity.

View Article and Find Full Text PDF

A 54-year-old male with liver cirrhosis (Child-Pugh score 5) presented with severe hepatogenous diabetes (HbA1c 12.6%). Contrast-enhanced CT showed a large portosystemic shunt from the inferior mesenteric vein to the left internal iliac vein.

View Article and Find Full Text PDF

Neurofibromatosis type 1 (NF1) is one of the most common genetic neurocutaneous disorders, and it is well known to be associated with peripheral or central nervous system malignancies. The most common malignant tumors are malignant peripheral nerve sheath tumors (MPNSTs); MPNSTs are the most common cause of death in patients with NF1. Central nervous system malignancies rarely occur.

View Article and Find Full Text PDF

Purpose: To evaluate osteoconductivity of a poly-L-lactide co-glycolide (PLG)-calcium sulfate (CS)-β-tricalcium phosphate (β-TCP) biocomposite suture anchor after arthroscopic shoulder labral repair.

Methods: The subjects of this study were patients who participated in a clinical trial for acquisition of marketing approval of a PLG-CS-β-TCP biocomposite anchor in Japan. They underwent arthroscopic labral repair using the anchor, and computed tomographic (CT) images of the glenoid were obtained 2 years after surgery.

View Article and Find Full Text PDF

Aim Of The Study: Diffusion-weighted image (DWI) of magnetic resonance imaging (MRI) can reveal high signal lesion in up to 50% of transient ischemic attack (TIA) patients. However, it is not well-known which factors determine developing DWI positivity. In order to answer this question, we analyzed factors relevant to DWI positivity in TIA patients.

View Article and Find Full Text PDF

Objectives: Neuroimaging markers for Parkinson's disease (PD)/dementia with Lewy bodies (DLB) include dopamine transporter (DAT) scanning and metaiodobenzylguanidine (MIBG) myocardial scintigraphy. It is unknown which marker is useful to identify the premotor phase PD/DLB. We reported four patients who, during a negative DAT scan period, had a positive MIBG result that suggested premotor PD/DLB.

View Article and Find Full Text PDF

Young-onset (< 65 years) dementia is a challenging clinical problem. A 61-year-old man visited our clinic because of a 2-year history of mild cognitive impairment of the executive disorder type. He was initially suspected of having young-onset Alzheimer's disease due to the lack of motor signs or hippocampal atrophy by conventional brain MRI.

View Article and Find Full Text PDF

Purpose: To evaluate and compare the femoral tunnel aperture position, graft bending angle and the magnetic resonance imaging (MRI) graft signal intensity after anatomical double-bundle anterior cruciate ligament (ACL) reconstruction between transtibial and transportal drilling techniques of the femoral tunnel.

Methods: Eighty-seven patients who underwent anatomic double-bundle ACL reconstruction with hamstring tendon autograft between January 2012 and December 2014 were included in this retrospective study. Forty-one patients underwent reconstruction using a transportal technique (TP group) and 46 patients underwent reconstruction using a transtibial technique (TT group).

View Article and Find Full Text PDF

Introduction: Apparent diffusion coefficient (ADC) values on multiparametric magnetic resonance imaging (mpMRI) have been reported to correlate with high-Gleason score (GS) prostate cancer. However, the relative ADC values between tumor lesions and normal tissue have been suggested as more suitable than the absolute ADC values for evaluation of diffusion abnormalities, because absolute ADC values are susceptible to differences in scanners or scanner settings. The present study evaluated the usefulness of the relative assessment of ADC values between tumor lesions and normal tissue on preoperative mpMRI for the prediction of high-risk prostate cancer on radical prostatectomy specimens.

View Article and Find Full Text PDF

Objective: Diagnosis of sporadic cerebellar ataxia is a challenge for neurologists. A wide range of potential causes exist, including chronic alcohol use, multiple system atrophy of cerebellar type (MSA-C), and sporadic late cortical cerebellar atrophy. Recently, an autosomal-dominant spinocerebellar ataxia (SCA) mutation was identified in a cohort of patients with non-MSA-C sporadic cerebellar ataxia.

View Article and Find Full Text PDF

Introduction: The characteristics of dementia with Lewy bodies (DLB), Alzheimer's disease (AD) and amnestic mild cognitive impairment (a-MCI) overlap but require different treatments; therefore, it is important to differentiate these pathologies. Assessment of dopamine uptake in the striatum using dopamine transporter (DaT) single-photon emission computed tomography (SPECT) is the gold standard for diagnosing DLB; however, this modality is expensive, time consuming and involves radiation exposure. Degeneration of the substantia nigra nigrosome-1, which occurs in DLB, but not in AD/a-MCI, can be identified by 3T susceptibility-weighted imaging (SWI).

View Article and Find Full Text PDF

Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder caused by a deficiency of alpha-galactosidase A. Approximately 50% of patients with AFD may have cardiac involvement. Gadolinium-enhanced cardiac magnetic resonance (CMR) is useful for the diagnosis of cardiac involvement of AFD by recognizing typical late gadolinium enhancement (LGE) patterns.

View Article and Find Full Text PDF

Aims Of Study: It is reported that severe bladder disorder in idiopathic normal-pressure hydrocephalus (iNPH) is predicted by right frontal hypoperfusion. However, it is not known whether bladder recovery is predicted by brain perfusion change after shunt surgery. To address this issue, we compared bladder and brain function before and after shunt surgery in iNPH.

View Article and Find Full Text PDF