Combination of waning immunity and lower effectiveness against new SARS-CoV-2 variants of approved COVID-19 vaccines necessitates new vaccines. We evaluated two doses, 28 days apart, of ARCT-154, a self-amplifying mRNA COVID-19 vaccine, compared with saline placebo in an integrated phase 1/2/3a/3b controlled, observer-blind trial in Vietnamese adults (ClinicalTrial.gov identifier: NCT05012943).
View Article and Find Full Text PDFFrom the beginning of the [Formula: see text] century until today, the demand for lighting systems includes not only visual parameters (brightness, contrast perception, color quality), but also non-visual parameters. It is necessary to define the new non-visual parameters for the realization of the new concept of Human Centric Lighting (HCL) or Integrative Lighting. As a contribution to this approach, many international research groups have tried to quantify the non-visual parameters such as Circadian Stimulus by Rea et.
View Article and Find Full Text PDFIn 1924, the CIE published and standardized the photopic luminous efficiency function. Based on the standardized curve, luminous flux in lumens, luminance in cd/m[Formula: see text], and illuminance in lux are determined by an integral of the curve and the incident light spectra in photometers and are considered physical brightness. However, human brightness perception is not only weighted by this simple determination, but is a more complicated combination of all L-cones, M-cones, S-cones, rods and later ipRGCs, which was partly described by the equivalent brightness of Fotios et al.
View Article and Find Full Text PDFSmart integrative lighting systems aim to support human health and wellbeing by capitalising on the light-induced effects on circadian rhythms, sleep, and cognitive functions, while optimising the light's visual aspects like colour fidelity, visual comfort, visual preference, and visibility. Metameric spectral tuning could be an instrument to solve potential conflicts between the visual preferences of users with respect to illuminance and chromaticity and the circadian consequences of the light exposure, as metamers can selectively modulate melanopsin-based photoreception without affecting visual properties such as chromaticity or illuminance. This work uses a 6-, 8- and 11-channel LED luminaire with fixed illuminance of 250 lx to systematically investigate the metameric tuning range in melanopic equivalent daylight illuminance (EDI) and melanopic daylight efficacy ratio (melanopic DER) for 561 chromaticity coordinates as optimisation targets (2700 K to 7443 K ± Duv 0 to 0.
View Article and Find Full Text PDF