CeO and CuO nanoparticles (NPs) are used as additives in petrodiesel to enhance engine performance leading to reduced diesel combustion emissions. Despite their benefits, the additive application poses human health concerns by releasing inhalable NPs into the ambient air. In this study, a bioinspired lung cell exposure system, Dosimetric Aerosol Inhalation Device (DAVID), was employed for evaluating the toxicity of aerosolized CeO and CuO NPs with a short duration of exposure (≤10 min vs.
View Article and Find Full Text PDFAromatic and aliphatic hydrocarbons (AAHs) are comprised of a variety of gaseous chemicals that may affect human and environmental health. To remove AAHs from air, polytetrafluoroethylene-nickel oxide (PTFE-NiO) composite nanofiber filter mats (NFMs) were synthesized and characterized for their ability to effectively adsorb AAHs. The NiO-nanoparticle-doped mats were fabricated by green electrospinning of PTFE and polyvinyl alcohol (PVA) mixtures added with nickel (II) nitrate hexahydrate in the spinning solution followed by surface heat treatment.
View Article and Find Full Text PDFAerosol transmission is one of the three major transmission routes of respiratory viruses. However, the dynamics and significance of the aerosol transmission route are not well understood, partially due to the lack of rapid and efficient tools for on-the-spot detection of airborne viruses. We report a hand-held device that integrates a 3D-printed sample preparation unit with a laminated paper-based RNA amplification unit.
View Article and Find Full Text PDFObjectives: Because the detection of SARS-CoV-2 RNA in aerosols but failure to isolate viable (infectious) virus are commonly reported, there is substantial controversy whether severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can be transmitted through aerosols. This conundrum occurs because common air samplers can inactivate virions through their harsh collection processes. We sought to resolve the question whether viable SARS-CoV-2 can occur in aerosols using VIVAS air samplers that operate on a gentle water vapor condensation principle.
View Article and Find Full Text PDFBackground - There currently is substantial controversy about the role played by SARS-CoV-2 in aerosols in disease transmission, due in part to detections of viral RNA but failures to isolate viable virus from clinically generated aerosols. Methods - Air samples were collected in the room of two COVID-19 patients, one of whom had an active respiratory infection with a nasopharyngeal (NP) swab positive for SARS-CoV-2 by RT-qPCR. By using VIVAS air samplers that operate on a gentle water-vapor condensation principle, material was collected from room air and subjected to RT-qPCR and virus culture.
View Article and Find Full Text PDFIn assessing the biological impact of airborne particles in vitro, air-liquid interface (ALI) exposure chambers are increasingly preferred over classical submerged exposure techniques, albeit historically limited by their inability to deliver sufficient aerosolized dose. A novel ALI system, the Dosimetric Aerosol in Vitro Inhalation Device (DAVID), bioinspired by the human respiratory system, uses water-based condensation for highly efficient aerosol deposition to ALI cell culture. Here, welding fumes (well-studied and inherently toxic ultrafine particles) were used to assess the ability of DAVID to generate toxicological responses between differing welding conditions.
View Article and Find Full Text PDFExposure to nanomaterials (NMs) is inevitable, requiring robust toxicological assessment to understand potential environmental and human health effects. NMs are favored in many applications because of their small size; however, this allows them to easily aerosolize and, subsequently, expose humans via inhalation. Toxicological assessment of NMs by conventional methods in submerged cell culture is not a relevant way to assess inhalation toxicity of NMs because of particle interference with bioassays and changes in particokinetics when dispersed in medium.
View Article and Find Full Text PDFA first-of-its-kind aerosol exposure device for toxicity testing, referred to as the Dosimetric Aerosol Inhalation Device (DAVID), was evaluated for its ability to deliver airborne nanoparticles to lung cells grown as air-liquid interface (ALI) cultures. For inhalation studies, ALI lung cell cultures exposed to airborne nanoparticles have more relevancy than the same cells exposed in submerged culture because ALI culture better represents the respiratory physiology and consequently more closely reflect cellular response to aerosol exposure. In DAVID, water condensation grows particles as small as 5 nm to droplets sized > 5 μm for inertial deposition at low flow rates.
View Article and Find Full Text PDFTo overcome limitations of existing air-cleaning filters in capturing and deactivating aerosolized microorganisms, this study was embarked to evaluate novel Ag, Zn, and Fe nanoparticle-doped cotton filters (AgCt, ZnCt, FeCt), as biocidal filters for bioaerosol attenuation. To evaluate the biocidal activity of the nanocomposite filters, the survival of lab-generated after collection on each filter material was compared to collection on an undoped cotton control filter and in a BioSampler. Relative humidity (RH) affected the survival of bacteria on the filters, and the optimal RH was found to be 50 ± 5%.
View Article and Find Full Text PDF