Publications by authors named "Tremsin A"

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.

View Article and Find Full Text PDF

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.

View Article and Find Full Text PDF
Article Synopsis
  • Optical imaging has been around for thousands of years, while radiographic imaging and tomography have developed significantly in the last 130 years, starting with the discovery of X-rays by Wilhelm Röntgen.
  • Both optical and radiographic imaging share common building blocks such as physics, sources, detectors, methods, and data science, which enhance their capabilities.
  • The evolution of these imaging techniques is pushing towards higher dimensions (like 4D) and is driven by technological advancements, aiming for better resolution, increased information yield, and integration of AI and automated data processing.
View Article and Find Full Text PDF
Article Synopsis
  • The NECTAR instrument utilizes thermal and fast neutrons for non-destructive inspection of large, dense objects, offering a unique radiography and tomography approach through scintillators and a camera system.
  • Gamma-rays, which are produced alongside neutrons and share a similar directional path, can be considered useful rather than just beam contamination; they can be detected through gamma-sensitive scintillator screens integrated into the existing detection setup.
  • This multimodal imaging technique improves depth penetration capabilities compared to traditional X-ray imaging, allowing better analysis of cm-sized objects by leveraging both neutron and gamma-ray data.
View Article and Find Full Text PDF

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station's beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI2D), is among the first eight instruments that will be commissioned at STS as part of the construction project.

View Article and Find Full Text PDF

Imaging using scintillators is a widespread and cost-effective approach in radiography. While different types of scintillator and sensor configurations exist, it can be stated that the detection efficiency and resolution of a scintillator-based system strongly depend on the scintillator material and its thickness. Recently developed event-driven detectors are capable of registering spots of light emitted by the scintillator after a particle interaction, allowing to reconstruct the Center-of-Mass of the interaction within the scintillator.

View Article and Find Full Text PDF

Bragg edge tomography was carried out on novel, ultra-thick, directional ice templated graphite electrodes for Li-ion battery cells to visualise the distribution of graphite and stable lithiation phases, namely LiC and LiC. The four-dimensional Bragg edge, wavelength-resolved neutron tomography technique allowed the investigation of the crystallographic lithiation states and comparison with the electrode state of charge. The tomographic imaging technique provided insight into the crystallographic changes during de-/lithiation over the electrode thickness by mapping the attenuation curves and Bragg edge parameters with a spatial resolution of approximately 300 µm.

View Article and Find Full Text PDF

Laser powder bed fusion is an additive manufacturing technique extensively used for the production of metallic components. Despite this process has reached a status at which parts are produced with mechanical properties comparable to those from conventional production, it is still prone to introduce detrimental tensile residual stresses towards the surfaces along the building direction, implying negative consequences on fatigue life and resistance to crack formations. Laser shock peening (LSP) is a promising method adopted to compensate tensile residual stresses and to introduce beneficial compressive residual stress on the treated surfaces.

View Article and Find Full Text PDF

Detectors with microchannel plates (MCPs) provide unique capabilities to detect single photons with high spatial (<10 µm) and timing (<25 ps) resolution. Although this detection technology was originally developed for applications with low event rates, recent progress in readout electronics has enabled their operation at substantially higher rates by simultaneous detection of multiple particles. In this study, the potential use of MCP detectors with Timepix readout for soft X-ray imaging and spectroscopic applications where the position and time of each photon needs to be recorded is investigated.

View Article and Find Full Text PDF

Artificial spin ices (ASI) have been widely investigated as magnetic metamaterials with exotic properties governed by their geometries. In parallel, interest in x-ray photon orbital angular momentum (OAM) has been rapidly growing. Here we show that a square ASI with a patterned topological defect, a double edge dislocation, imparts OAM to scattered x rays.

View Article and Find Full Text PDF

Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L-edge on a charge-density-wave material TiSe.

View Article and Find Full Text PDF

The exciton-phonon coupling in highly oriented pyrolytic graphite is studied using resonant inelastic x-ray scattering (RIXS) spectroscopy. With ∼70  meV energy resolution, multiple low energy excitations associated with coupling to phonons can be clearly resolved in the RIXS spectra. Using resonance dependence and the closed form for RIXS cross section without considering the intermediate state mixing of phonon modes, the dimensionless coupling constant g is determined to be 5 and 0.

View Article and Find Full Text PDF

Neutron Bragg edge imaging enables spatially resolved studies of crystalline features through the exploitation and analysis of Bragg edges in the transmission spectra recorded in each pixel of an imaging detector. Studies with high spectral resolutions, as is required e.g.

View Article and Find Full Text PDF

Energy-resolved neutron imaging experiments conducted on the Small Angle Neutron Scattering (SANS) instrument, Bilby, demonstrate how the capabilities of this instrument can be enhanced by a relatively simple addition of a compact neutron counting detector. Together with possible SANS sample surveying and location of the region of interest, this instrument is attractive for many imaging applications. In particular, the combination of the cold spectrum of the neutron beam and its pulsed nature enables unique non-destructive studies of the internal structure for samples that are opaque to other more traditional techniques.

View Article and Find Full Text PDF

The mobility of magnetic domains forms the link between the basic physical properties of a magnetic material and its global characteristics such as permeability and saturation field. Most commonly, surface domain structure are studied using magneto-optical Kerr microscopy. The limited information depth of approx.

View Article and Find Full Text PDF

Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively with the potential to probe the interior of bulk samples which is not amenable otherwise. Using a pioneering polarimetric set-up for ToF neutron instrumentation in combination with a newly developed tailored reconstruction algorithm, the magnetic field generated by a current carrying solenoid has been measured and reconstructed, thereby providing the proof-of-principle of a technique able to reveal hitherto unobtainable information on the magnetic fields in the bulk of materials and devices, due to a high degree of penetration into many materials, including metals, and the sensitivity of neutron polarisation to magnetic fields. The technique puts the potential of the ToF time structure of pulsed neutron sources to full use in order to optimise the recorded information quality and reduce measurement time.

View Article and Find Full Text PDF

The physical properties of polycrystalline materials depend on their microstructure, which is the nano- to centimeter scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study centimeter-sized bulk samples with a spatial resolution of hundred micrometers: time-of-flight three-dimensional neutron diffraction (ToF 3DND).

View Article and Find Full Text PDF

A new ion-ion coincidence imaging spectrometer based on a pixelated complementary metal-oxide-semiconductor detector has been developed for the investigation of molecular ionization and fragmentation processes in strong laser fields. Used as a part of a velocity map imaging spectrometer, the detection system is comprised of a set of microchannel plates and a Timepix detector. A fast time-to-digital converter (TDC) is used to enhance the ion time-of-flight resolution by correlating timestamps registered separately by the Timepix detector and the TDC.

View Article and Find Full Text PDF

Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution.

View Article and Find Full Text PDF
Article Synopsis
  • Energy-resolved neutron imaging allows for detailed, non-destructive analysis of materials, particularly effective at bright pulsed spallation neutron sources due to advancements in neutron detectors.
  • This method was exemplified through a study of natural gold samples, mapping palladium distributions and revealing crystalline structures within the gold.
  • The technique involves measuring neutron transmission spectra across multiple energy ranges with high spatial resolution, providing a promising alternative to traditional methods that struggle with opaque samples.
View Article and Find Full Text PDF
Article Synopsis
  • Non-destructive testing using neutron imaging and diffraction allows for examination of thick metal samples, which are often opaque to other methods.
  • This technique, known as spatially resolved neutron transmission spectroscopy, captures multiple images at different energies for detailed analysis of internal structures.
  • The study showcases imaging of microstructural properties in Inconel 625, aiding in the optimization of additive manufacturing processes and providing data to validate predictive models used in industry.
View Article and Find Full Text PDF

This paper reports the design, making and characterisation of a series of Fe-based bulk metallic glass alloys with the aim of achieving the combined properties of high neutron absorption capability and sufficient glass forming ability. Synchrotron X-ray diffraction and pair distribution function methods were used to characterise the crystalline or amorphous states of the samples. Neutron transmission and macroscopic attenuation coefficients of the designed alloys were measured using energy resolved neutron imaging method and the very recently developed microchannel plate detector.

View Article and Find Full Text PDF

We present a picosecond time-resolved X-ray absorption spectroscopy (tr-XAS) setup designed for synchrotron-based studies of interfacial photochemical dynamics. The apparatus combines a high power, variable repetition rate picosecond laser system with a time-resolved X-ray fluorescence yield detection technique. Time-tagging of the detected fluorescence signals enables the parallel acquisition of X-ray absorption spectra at a variety of pump-probe delays employing the well-defined time structure of the X-ray pulse trains.

View Article and Find Full Text PDF
Article Synopsis
  • The paper discusses a nondestructive method using energy-resolved neutron imaging to analyze the internal structure and material gradients of different metal-alloy welds, including those made from aluminum to steel and titanium to stainless steel with copper as a filler.
  • Neutrons can penetrate thick metals, allowing researchers to study features like internal strain, microstructure, and defects that are not visible with traditional techniques.
  • The study shows that this imaging method can provide detailed maps of the weld characteristics, such as texture, voids, and thermal front depth, which can help improve welding processes and material performance.
View Article and Find Full Text PDF

Spin-Echo Modulated Small Angle Neutron Scattering (SEMSANS) in Time-of-Flight (ToF) mode has been shown to be a promising technique for measuring (very) small angle neutron scattering (SANS) signals and performing quantitative Dark-Field Imaging (DFI), i.e., SANS with 2D spatial resolution.