Publications by authors named "Traino A"

Article Synopsis
  • The study investigated the noise reduction capabilities of a photon-counting detector (PCD) in computed tomography (CT) using a model-based iterative reconstruction algorithm (QIR).
  • Forty repeated scans were conducted on a water phantom and compared with a conventional energy-integrating detector (EID) to assess noise characteristics.
  • Results showed that PCD-CT significantly reduced noise levels and improved image uniformity, demonstrating the effectiveness of QIR in decreasing noise without altering the overall distribution of noise values.
View Article and Find Full Text PDF

Radiomics of cardiac magnetic resonance (MR) imaging has proved to be potentially useful in the study of various myocardial diseases. Therefore, assessing the repeatability degree in radiomic features measurement is of fundamental importance. The aim of this study was to assess test-retest repeatability of myocardial radiomic features extracted from quantitative T1 and T2 maps.

View Article and Find Full Text PDF

Introduction: A system for stabilizing and monitoring eye movements during LINAC-based photon beam one single fraction stereotactic radiotherapy was developed at our Institution. This study aimed to describe the feasibility and the efficacy of our noninvasive optical localization system that was developed, tested, and applied in 20 patients treated for uveal melanoma.

Methods: Our system consisted of a customized thermoplastic mask to immobilize the head, a gaze fixation LED, and a digital micro-camera.

View Article and Find Full Text PDF

Radiomics and artificial intelligence have the potential to become a valuable tool in clinical applications. Frequently, radiomic analyses through machine learning methods present issues caused by high dimensionality and multicollinearity, and redundant radiomic features are usually removed based on correlation analysis. We assessed the effect of preprocessing-in terms of voxel size resampling, discretization, and filtering-on correlation-based dimensionality reduction in radiomic features from cardiac T1 and T2 maps of patients with hypertrophic cardiomyopathy.

View Article and Find Full Text PDF

Radiomics is emerging as a promising and useful tool in cardiac magnetic resonance (CMR) imaging applications. Accordingly, the purpose of this study was to investigate, for the first time, the effect of image resampling/discretization and filtering on radiomic features estimation from quantitative CMR T1 and T2 mapping. Specifically, T1 and T2 maps of 26 patients with hypertrophic cardiomyopathy (HCM) were used to estimate 98 radiomic features for 7 different resampling voxel sizes (at fixed bin width), 9 different bin widths (at fixed resampling voxel size), and 7 different spatial filters (at fixed resampling voxel size/bin width).

View Article and Find Full Text PDF

The purpose of this study was to investigate the effect of image preprocessing on radiomic features estimation from computed tomography (CT) imaging of locally advanced rectal cancer (LARC). CT images of 20 patients with LARC were used to estimate 105 radiomic features of 7 classes (shape, first-order, GLCM, GLDM, GLRLM, GLSZM, and NGTDM). Radiomic features were estimated for 6 different isotropic resampling voxel sizes, using 10 interpolation algorithms (at fixed bin width) and 6 different bin widths (at fixed interpolation algorithm).

View Article and Find Full Text PDF

Background: In the context of the coronavirus disease 2019 (COVID-19) pandemic, liver-directed therapies (LDTs) may offer minimally invasive integrative tools for tumor control. Among them, selective internal radiation therapy (SIRT) represents a safe, flexible and effective treatment. Purpose of this study is to present our experience with SIRT during the first wave of COVID-19 pandemic and provide an overview of the indications and challenges of SIRT in this scenario.

View Article and Find Full Text PDF

Radioembolization is a valuable therapeutic option in patients with unresectable intrahepatic cholangiocarcinoma. The essential implementation of the absorbed dose calculation methods should take into account also the specific tumor radiosensitivity, expressed by the α parameter. Purpose of this study was to retrospectively calculate it in a series of patients with unresectable intrahepatic cholangiocarcinoma submitted to radioembolization.

View Article and Find Full Text PDF

Digital breast tomosynthesis (DBT) has recently gained interest both for breast cancer screening and diagnosis. Its employment has increased also in conjunction with digital mammography (DM), to improve cancer detection and reduce false positive recall rate. Synthetic mammograms (SMs) reconstructed from DBT data have been introduced to replace DM in the DBT + DM approach, for preserving the benefits of the dual-acquisition modality whilst reducing radiation dose and compression time.

View Article and Find Full Text PDF

Background: To propose a practical and simple method to individually evaluate the average absorbed dose for digital breast tomosynthesis.

Methods: The method is based on the estimate of incident air kerma (k) on the breast surface. An analytical model was developed to calculate the k from the tube voltage, tube load, breast thickness, x-ray tube yield, and anode-filter combination.

View Article and Find Full Text PDF

Recent advances in digital breast tomosynthesis (DBT) technology were focused on the reconstruction of 2D "Synthesized Mammograms" (SMs) from DBT dataset. The introduction of SMs could avoid an additional digital mammography (DM) which is often required in complement to DBT examinations. Therefore, breast absorbed dose and compression time can be significantly reduced in DBT+SM procedures with respect to DBT+DM modality.

View Article and Find Full Text PDF

Purpose: To retrospectively compare early response to yttrium-90 radioembolization (Y90) according to volumetric iodine uptake (VIU) changes, Response Evaluation Criteria In Solid Tumor 1.1 (RECIST 1.1) and modified RECIST (mRECIST) in patients with intermediate-advanced hepatocellular carcinoma (HCC) and to explore their association with survival.

View Article and Find Full Text PDF

Background: The new European Directive 2013/59/EURATOM requires that patients are informed about the risk associated with ionising radiation and that detailed information on patient exposure is included in the radiological report. This implies a revision of the routinely used dose indexes to obtain quantities related to individual exposure evaluable from acquisition parameters. Here we propose a new mammography dose index consistent with the average glandular dose ().

View Article and Find Full Text PDF

Purpose: We propose to summarize the advancements introduced by the new Directive 2013/59/Euratom concerning the concept of clearance, for which the radioactive medical waste represents a typical candidate. We also intend to spotlight disputable points in the regulatory scheme in force in Italy, as well to make a contribution to evaluate whether the practice of patients' urine storing, stated by it, can be regarded to be proper.

Methods: With directing our interest to radionuclides used in Nuclear Medicine, we first present an overview of how the clearance concept, and that of exemption closely related to it, have been developed from the previous Directive 96/29 to the new one; then we describe the implementation of these concepts in the Italian legislation.

View Article and Find Full Text PDF

Radionuclide therapy is a systemic treatment that aims to deliver cytotoxic radiation to cancer cells. Due to their properties, antibodies have been considered as suitable agent for the delivery of therapeutic radioisotopes, radioimmunotherapy (RIT). This article gives an overview of new approaches for imaging and therapy of solid cancer with particular attention to strategies to enhance treatment success.

View Article and Find Full Text PDF

In this paper we report on a successful management of multiple bone metastases from differentiated thyroid cancer. In 2007, a 75-year-old female patient, previously referred for thyroidectomy for multinodular goiter, underwent surgical removal of a lumbar mass with histological findings of metastasis from well differentiated thyroid cancer. After surgery, serum thyroglobulin (sTg) was 204.

View Article and Find Full Text PDF

Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the breast. In particular, phantom acquisitions were performed on three 1.

View Article and Find Full Text PDF

Purpose: The precise determination of organ mass (mth) and total number of disintegrations within the thyroid gland (Ã) are essential for thyroid absorbed-dose calculations for radioiodine therapy. Nevertheless, these parameters may vary according to the method employed for their estimation, thus introducing uncertainty in the estimated thyroid absorbed dose and in any dose-response relationship derived using such estimates. In consideration of these points, thyroid absorbed doses for Graves' disease (GD) treatment planning were calculated using different approaches to estimating the mth and the Ã.

View Article and Find Full Text PDF

Anthropomorphic tissue-equivalent hand phantoms were achieved to measure the extremity dose involved in Zevalin (90)Y-labelling and patient delivering procedure for radioimmunotherapy treatment of non-Hodgkin lymphoma. The extremity doses to hands and wrists of operators were measured by using thermoluminescent detectors mounted on the developed phantoms. Measurements of chest- and lens-equivalent doses performed on a Rando phantom are also reported.

View Article and Find Full Text PDF

Purpose: Nonuniform activity within the target lesions and the critical organs constitutes an important limitation for dosimetric estimates in patients treated with tumor-seeking radiopharmaceuticals. The tumor control probability and the normal tissue complication probability are affected by the distribution of the radionuclide in the treated organ/tissue. In this paper, a straightforward method for calculating the absorbed dose at the voxel level is described.

View Article and Find Full Text PDF

Purpose: Thyroid (131)I effective half-life (T(eff)) is an essential parameter in patient therapy when accurate radiation dose is desirable for producing an intended therapeutic outcome. Multiple (131)I uptake measurements and resources from patients themselves and from nuclear medicine facilities are requisites for determining T(eff), these being limiting factors when implementing the treatment planning of Graves' disease (GD) in radionuclide therapy. With the aim of optimizing this process, this study presents a practical, propitious, and accurate method of determining T(eff) for dosimetric purposes.

View Article and Find Full Text PDF

Aim: There is no consensus regarding the most appropriate dosimetric approach to cure Graves' disease. This study describes a personalized approach based on the desired therapy-induced volume (mass) reduction in order to define the activity of 131I-iodide to be administered, based on the MIRD approach and the radiobiological Linear Quadratic Model.

Methods: A model for calculating the "optimal" final thyroid mass has been developed and published in the past years.

View Article and Find Full Text PDF

Purpose: Diffusion tensor imaging (DTI) is highly sensitive to noise and improvement of radiofrequency coil technology represents a straightforward way for augmenting signal-to-noise ratio (SNR) performance in magnetic resonance imaging (MRI) scanners. The aim of this study was to characterize the dependence of DTI measurements of fractional anisotropy (FA) and mean diffusivity (MD) on the choice of head coil, comparing two head coils with different functional designs and sensitivities.

Methods: Fourteen healthy subjects underwent DTI acquisitions at 1.

View Article and Find Full Text PDF

Calculation of the therapeutic activity of radioiodine (131)I for individualized dosimetry in the treatment of Graves' disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of (131)I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the time-integrated activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods.

View Article and Find Full Text PDF