To develop and validate a novel noncontrast time-resolved magnetic resonance angiography (NC TR-MRA) using consecutive beam pulses with variable flip angles for visualizing hemodynamics in the pulmonary artery, we performed phantom and volunteer studies and applied the novel NC TR-MRA to a 51-year-old woman with pulmonary arteriovenous malformation (PAVM).The novel NC TR-MRA sequence utilized consecutive multiple-beam saturation pulses with variable flip angles considering venous blood T1 relaxation to alter the visualized blood signal length. The flowing blood signal length is suppressed according to the number of beam saturation pulses.
View Article and Find Full Text PDFThis study aimed to develop and test a simultaneous acquisition and analysis pipeline for voxel-based magnetic susceptibility and morphometry (VBMSM) on a single dataset using young volunteers, elderly healthy volunteers, and an Alzheimer's disease (AD) group. 3D T -weighted and multi-echo phase images for VBM and quantitative susceptibility mapping (QSM) were simultaneously acquired using a magnetization-prepared spoiled turbo multiple gradient echo sequence with inversion pulse for QSM (MP-QSM). The magnitude image was split into gray matter (GM) and white matter (WM) and was spatially normalized.
View Article and Find Full Text PDFPurpose: To suppress olefinic signals and enable simultaneous and quantitative estimation of multiple functional parameters associated with water and lipid, we investigated a modified method using chemical shift displacement and recovery-based separation of lipid tissue (SPLIT) involving acquisitions with different inversion times (TIs), echo times (TEs), and b-values.
Materials And Methods: Single-shot diffusion echo-planar imaging (SSD-EPI) with multiple b-values (0-3000 s/mm) was performed without fat suppression to separate water and lipid images using the chemical shift displacement of lipid signals in the phase-encoding direction. An inversion pulse (TI = 292 ms) was applied to SSD-EPI to remove olefinic signals.
Purpose: To obtain water and lipid diffusion-weighted images (DWIs) simultaneously, we devised a novel method utilizing chemical shift displacement-based separation of lipid tissue (SPLIT) imaging.
Materials And Methods: Single-shot diffusion echo-planar imaging without fat suppression was used and the imaging parameters were optimized to separate water and lipid DWIs by chemical shift displacement of the lipid signals along the phase-encoding direction. Using the optimized conditions, transverse DWIs at the maximum diameter of the right calf were scanned with multiple b-values in five healthy subjects.
Nihon Hoshasen Gijutsu Gakkai Zasshi
January 2016