: Transthoracic echocardiography (TTE) is the gold standard modality for evaluating cardiac morphology, function, and hemodynamics in clinical practice. While artificial intelligence (AI) is expected to contribute to improved accuracy and is being applied clinically, its impact on daily clinical practice has not been fully evaluated. : We retrospectively examined 30 consecutive patients who underwent AI-equipped TTE at a single institution.
View Article and Find Full Text PDFBackground: Although Doppler evaluation using a multiplanar method is recommended to assess the severity of aortic stenosis (AS) with transthoracic echocardiography, evidence on the diagnostic significance of a non-apical method is limited. This study aimed to compare the use of the apical with the use of the right parasternal view (RPV) method to evaluate AS severity and to examine the diagnostic significance of performing the RPV method in addition to the apical method during the evaluation.
Methods: This retrospective observational study included 276 consecutive patients (mean age: 79 ± 10 years; women, 56%) with severe AS (aortic valve area [AVA] ≤1.