The present study evaluated the organ doses, effective doses and conversion factors from the dose-area product to effective dose in pediatric diagnostic cardiac catheterization performed by in-phantom dosimetry and Monte Carlo simulation. The organ and effective doses in 5-y-olds during diagnostic cardiac catheterizations were evaluated using radiophotoluminescence glass dosemeters implanted into a pediatric anthropomorphic phantom and PCXMC software. The mean effective dose was 3.
View Article and Find Full Text PDFThe present study evaluated the organ and effective doses in infant diagnostic cardiac catheterisation performed using a modern x-ray imaging unit by in-phantom dosimetry. In addition, conversion factors from dose-area product (DAP) to effective dose were determined. The organ and effective doses in 1-year old during diagnostic cardiac catheterisations were measured using radiophotoluminescence glass dosemeters implanted into an infant anthropomorphic phantom.
View Article and Find Full Text PDFAJR Am J Roentgenol
September 2015
Objective: Radiation exposure to neonates and infants during cardiac catheterizations is an important issue. Smaller patient size and higher heart rate in these patients result in a greater need for magnification modes and higher frame rates, all of which contribute to a significant increase in radiation doses. The aims of our study were to evaluate organ and effective doses for neonates and infants during diagnostic cardiac catheterizations on the basis of in-phantom dosimetry and conversion factors from dose-area product (DAP) to the effective dose.
View Article and Find Full Text PDFSpontaneous spinal epidural hematoma(SSEH)is a rare condition that typically presents with acute back pain and paraparesis or quadriparesis. However, hemiparesis is a rare initial symptom of SSEH. Here, we report two cases of SSEH presenting with hemiparesis, which were difficult to distinguish from cerebral stroke.
View Article and Find Full Text PDFOrgan and effective doses during paediatric chest radiographic examination were investigated for various tube voltages between 60 and 110 kV at a constant milliampere-second value and focus-to-film distance by using an in-phantom dose measuring system and a Monte Carlo (MC) simulation software (PCXMC), where the former was composed of 32 photodiode dosemeters embedded in various tissue and organ sites within a 6-y-old child anthropomorphic phantom. Lung doses obtained ranged from 0.010 to 0.
View Article and Find Full Text PDF