Titanium (Ti) is an attractive material, abundant in nature and possessing superior mechanical and chemical properties. However, its widespread use is significantly hampered by the strong affinity between titanium and oxygen (O), resulting in elevated manufacturing costs during the refining, melting, and casting processes. The current work introduces a high-throughput technique that effectively reduces the oxygen content in molten titanium to a level suitable for structural material applications (1000 mass ppm, equivalent to 0.
View Article and Find Full Text PDFPurpose: This study investigated whether additive manufactured (AM) surfaces inhibit accumulation of bacterial biofilm on the surfaces of Ti-6Al-4V alloy dental implants. Bacterial biofilms are thought to cause peri-implant disease, which develops in mucosa surrounding titanium (Ti) and Ti alloy dental implants and can lead to bone loss and implant failure.
Methods: Accumulation of a Streptococcus mutans (ATCC 25175) biofilm on Ti-6Al-4V alloy was compared in relation to fabrication method, ie, AM using electron beam melting (EBM) or laser beam melting (LBM).
Faraday Discuss
August 2016
Deoxidation of Ti, or direct removal of O dissolved in metallic Ti, is known to be extremely difficult when Mg is used as the deoxidizing agent. This difficulty arises because the chemical potential of O2, pO2, under Mg/MgO equilibrium is high (approximately 10(-41) atm at 1200 K) and is equivalent to that of Ti containing ∼2 mass% O at 1200 K. Therefore, when deoxidizing Ti to the commercial level of high-grade pure Ti (below 0.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
January 2013
Customized one-component dental implants have been fabricated using Electron Beam Melting(®) (EBM(®)), which is a rapid prototyping and manufacturing technique. The goal of our study was to determine the effect of electron beam orientation on the fatigue resistance of EBM Ti-6Al-4V ELI alloy. EBM technique was used to fabricate Ti-6Al-4V ELI alloy blocks, which were cut into rectangular beam specimens with dimensions of 25 × 4 × 3 mm, such that electron beam orientation was either parallel (group A) or perpendicular (group B) to the long axis of the specimens.
View Article and Find Full Text PDFStatement Of Problem: Although pure titanium is known to have good biocompatibility, a titanium alloy with better strength is needed for fabricating clinically acceptable, partial removable dental prosthesis (RDP) frameworks.
Purpose: The mechanical properties of an experimental Ti-5Al-5Cu alloy cast with a 2-step investment technique were examined for RDP framework applications.
Material And Methods: Patterns for tests for various properties and denture frameworks for a preliminary trial casting were invested with a 2-step coating method using 2 types of mold materials: a less reactive spinel compound (Al(2)O(3)·MgO) and a less expensive SiO(2)-based material.
This study characterized properties of Ti-6Al-4V ELI (extra low interstitial, ASTM grade 23) specimens fabricated by a laser beam melting (LBM) and an electron beam melting (EBM) system for dental applications. Titanium alloy specimens were made into required size and shape for each standard test using fabrication methods. The LBM specimens were made by an LBM machine utilizing 20 µm of Ti-6Al-4V ELI powder.
View Article and Find Full Text PDFThe hardened alpha-case (alpha-case) layer inevitably forms on the surface of titanium castings when prepared by investment casting. Because the hardness of the alpha-case is incomparable to that of the interior structure, the perception exists that the alpha-case is difficult to remove during cutting, grinding and polishing. Grindability (ease of grinding) of cast cpTi and cast Ti-6Al-4V was evaluated by grinding cast specimens incrementally using a SiC abrasive wheel.
View Article and Find Full Text PDFPurpose: This study investigated the grindability of cast Ti-6Al-4V alloyed with copper.
Materials And Methods: The metals tested were commercially pure titanium (CP Ti), Ti-6Al-4V, experimental Ti-6Al-4V-Cu (1, 4, and 10 wt% Cu), and Co-Cr alloy. Each metal was cast into five blocks (3.
The use of dental amalgam has declined, but in most of the world, amalgam is the most widely used and widely taught direct restorative material for load-bearing posterior restorations. There are few national regulations on the use of amalgam; however, there are several nations where few amalgam restorations are placed. Long-term studies have shown that under optimum conditions, posterior restorations of amalgam and resin composite last longer than reported previously and that amalgam restorations outlast composite restorations.
View Article and Find Full Text PDFThis study investigated the interfacial microstructure between gold-coated titanium and low-fusing porcelain. The square surfaces of cast titanium split rods were sputter-coated with gold using a sputter coater at 40 mA for 1,000 seconds. Specimens were prepared for transmission electron microscopy (TEM) by cutting and polishing two pieces of the gold-coated split-rod specimens, which were glued and embedded in Cu tubes with an epoxy adhesive.
View Article and Find Full Text PDFThe wear behavior of Ti-based alloys was analyzed by considering the elastic-plastic fracture of individual alloys in response to the relevant contact stress field. Using the contact stresses as the process driving force, wear was computed as the wear rate or volume loss as a function of hardness and tensile ductility for Ti-based cast alloys containing an alpha, alpha+beta or beta microstructure with or without the intermetallic precipitates. Model predictions indicated that wear of Ti alloys increases with increasing hardness but with decreasing fracture toughness or tensile ductility.
View Article and Find Full Text PDFAnodic polarization tests were performed in 0.9% NaCl and 1% lactic acid solutions to characterize the relationship between the corrosion behavior and the microstructures of cast Ti-Ag (5-40% Ag) alloys. The anodic polarization curves for the Ti-Ag alloys up to 17.
View Article and Find Full Text PDFAs part of our systematic studies characterizing the properties of titanium alloys, we investigated the grindability of a series of cast Ti-Hf alloys. Alloy buttons with hafnium concentrations up to 40 mass% were made using an argon-arc melting furnace. Each button was cast into a magnesia-based mold using a dental titanium casting machine; three specimens were made for each metal.
View Article and Find Full Text PDFIt has recently been found that alloying with copper improved the inherently poor grindability and wear resistance of titanium. This study characterized the corrosion behavior of cast Ti-6Al-4V alloyed with copper. Alloys (0.
View Article and Find Full Text PDFThis study examined the mechanical properties of a series of Ti-Hf alloys. Titanium alloys with 10 to 40 mass % Hf were made with titanium and hafnium sponge in an argon-arc melting furnace. Specimens cast into magnesia-based investment molds were tested for yield strength, tensile strength, percentage elongation, and modulus of elasticity.
View Article and Find Full Text PDFWe examined the mold filling capacity and microhardness of two industrial 1% Fe titanium alloys: Super-TIX800 (Nippon Steel Corp.) (Fe: 0.910%, O: 0.
View Article and Find Full Text PDFAnodic polarization was performed in 0.9% NaCl and 1% lactic acid solutions to characterize the relationship between the corrosion behavior and microstructures of cast Ti-Au (5-40%) alloys. An abrupt increase in the current density occurred at approximately 0.
View Article and Find Full Text PDFObjective: The goal of this work was to improve the mechanical strength of laser-welded gold alloy with age-hardenability at intraoral temperature.
Methods: The gold alloy was cast conventionally in plate patterns (0.5 mm x 3.
Purpose: To examine the effect of using metal primers to enhance the shear bond strength of a laboratory-cured prosthetic composite to cast metal surfaces.
Methods: Cast discs (10 mm diam., 2.
A mercury plating technique was used to determine the phases forming on experimental Ag-Sn-Cu alloy powders (with and without Pd) exposed to electrolytically deposited mercury. Four series of alloy powders were made: a) 1.5% Pd with 10-14% Cu (CU series); b) 1.
View Article and Find Full Text PDFPurpose: To examine the effect of welding method and heat treatment on the strength of laser-welded gold alloy with age-hardenability at intraoral temperature.
Methods: Cast gold alloy plates (0.5 x 3.
Experimental Ti-Ag alloys (5, 10, and 20 mass% Ag) and Ti-Cu alloys (2, 5, and 10 mass% Cu) were cast into magnesia molds using a dental casting machine, and their grindability was investigated. At the lowest grinding speed (500 m min(-1)), there were no statistical differences among the grindability values of the titanium and titanium alloys. The grindability of the alloys increased as the grinding speed increased.
View Article and Find Full Text PDF