Publications by authors named "Toru Moro"

Background: While fear of movement is an important predictor of pain and disability in osteoarthritis (OA), its impact on patients with hip OA remains uncertain. This study aimed to determine whether fear of movement, evaluated by the Tampa Scale for Kinesiophobia (TSK)-11, and pain catastrophizing, evaluated by the Pain Catastrophizing Scale (PCS), were associated with quality of life (QOL) in patients with hip OA.

Methods: This cross-sectional study was conducted between November 2017 and December 2018.

View Article and Find Full Text PDF

Rigid spinal fusion with instrumentation has been widely applied in treating degenerative spinal disorders and has shown excellent and stable surgical results. However, adjacent segment pathology or implants' loosening could be problematic due to the spine's segmental fusion. Therefore, this study verified a novel concept for posterior stabilization with polyethylene inserts inside a pedicle screw assembly using bone models.

View Article and Find Full Text PDF

Introduction: Total hip arthroplasty (THA) after rotational acetabular osteotomy (RAO) is technically demanding because of the characteristic acetabular morphology after RAO. The present study aimed to investigate the differences in the three-dimensional cup position between THA after RAO and primary THA.

Materials And Methods: We analysed the pre-operative and post-operative computed tomography (CT) data of 120 patients (20 patients after RAO and 100 patients without a history of RAO) who underwent THA between January 2017 and June 2018.

View Article and Find Full Text PDF

Introduction: A disintegrin and metalloproteinase 17 (Adam17), also known as TNFα-converting enzyme (Tace), is a membrane-anchored protein involved in shedding of TNF, IL-6 receptor, ligands of epidermal growth factor receptor (EGFR), and Notch receptor. This study aimed to examine the role of Adam17 in adult articular cartilage and osteoarthritis (OA) pathophysiology.

Materials And Methods: Adam17 expression was examined in mouse knee joints during OA development.

View Article and Find Full Text PDF

Measurements of wear resistance and metal ion release are important for designing bearing couples or interfaces in total hip arthroplasty (THA). In this study, we investigated wear resistance and metal ion release of surface-modified metal-free all-polymer hip bearings, such as poly(ether-ether-ketone), (PEEK) on cross-linked polyethylene (PEEK-on-CLPE), with a hydrated gel-like surface layer, to propose an improved alternative to the conventional materials used to design THA bearings. The PEEK surface resulted in less metal ion release than the cobalt-chromium-molybdenum (Co-Cr-Mo) alloy surface owing to the lack of metal.

View Article and Find Full Text PDF

Background: Rotational acetabular osteotomy (RAO) is a type of pelvic osteotomy performed to improve the acetabular bony coverage against the femoral head for patients with acetabular dysplasia. The acetabular bony coverage is ideally evaluated three-dimensionally; however, there is a paucity of published data regarding three-dimensional morphology in patients with long-term excellent outcome after RAO. The present study investigated the characteristics of three-dimensional acetabular morphology with long-term excellent outcome after RAO in comparison to patients with normal hip joints and those converted to total hip arthroplasty (THA) after RAO because of osteoarthritis (OA) progression.

View Article and Find Full Text PDF

Initial bacterial adhesion to medical devices and subsequent biofilm formation are known as the leading causes of surgical site infection (SSI). Therefore, inhibition of bacterial adhesion and biofilm formation on the surface of medical devices can reduce the risk of SSIs. In this study, a highly hydrophilic, antibiofouling surface was prepared by coating the bioabsorbable suture surface with poly(2-methacryloyloxyethyl phosphorylcholine (MPC)-co-n-butyl methacrylate) (PMB).

View Article and Find Full Text PDF

Purpose: The results of reamed bipolar hemiarthroplasty (BHA) in patients with hip osteoarthritis (OA) are reported to be unfavorable. Acetabular reaming for sufficient bony coverage caused bipolar head migration into the superomedial direction, and most patients required revision surgeries. Several methods are applicable to treat decreased bone stock.

View Article and Find Full Text PDF

Although laboratory tests and mid-term clinical outcomes show the clinical safety and remarkable wear resistance of the highly cross-linked polyethylene (HXLPE) acetabular liner with a nanometer-scaled graft layer of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC), the wear resistance of the layer under severe abrasive conditions is concerning. We evaluated the effects of a roughened femoral head and the grafting locus on the wear resistance of the PMPC-grafted HXLPE liner and the effect of PMPC grafting on wear resistance of the HXLPE substrate by removing the PMPC-grafted layer using a severely roughened femoral head. Against a moderately roughened femoral head, the PMPC-grafted HXLPE liner showed negative wear, although an untreated HXLPE liner increased the wear by 154.

View Article and Find Full Text PDF

To overcome clinical issues caused by large bone defects and subsequent nonunion, various approaches to bone regeneration have been researched, including tissue engineering, biomaterials, stem cells and drug screening. Previously, we developed a free-standing biodegradable polymer nanosheet composed of poly(L-lactic acid) (PLLA) using a simple fabrication process consisting of spin-coating and peeling techniques. We reported that sandwich-type PLLA nanosheets loaded with recombinant human bone morphogenetic protein-2 (rhBMP-2) displayed long-lasting, sustained release of rhBMP-2, and markedly enhanced bone regeneration in mouse calvarial bone defects.

View Article and Find Full Text PDF

Recently, traditional strategies for manipulating orthopedic bearing substrates have attempted to improve their wear resistance by adjusting polyethylene substrate through cross-linking and antioxidant blending. However, further research is required on the substrate, as well as the surface focused on the structure and role of articular cartilage. We therefore develop an orthopedic bearing surface comprising a nanometer-scale hydrated gel-like layer by grafting highly hydrophilic poly(2-methacryloyloxyethyl phosphorylcholine), with the aim of mimicking the lubrication mechanism of articular cartilage, and investigate its surface characteristics, bulk characteristics, and behavior under load bearing conditions upon accelerated aging.

View Article and Find Full Text PDF

Purpose: Rotational acetabular osteotomy is a type of pelvic osteotomy that involves rotation of the acetabular bone to improve the bony coverage of the femoral head for patients with acetabular dysplasia. Favourable post-operative long-term outcomes have been reported in previous studies. However, there is a paucity of published data regarding three-dimensional bony coverage.

View Article and Find Full Text PDF

Manipulating the surface and substrate of cross-linked polyethylene (CLPE) is an essential approach for obtaining life-long orthopedic bearings. We therefore proposed a bearing material comprised of an antioxidative substrate generated by vitamin E blending (HD-CLPE[VE]) with a poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted surface, and investigated its wear resistance and oxidative stability under accelerated aging and load bearing conditions. Neither the hydration nor friction kinetics of the molecular network structure of the PMPC-grafted surface or the HD-CLPE(VE) substrate were influenced by accelerated aging but rather exhibited high stability even under high oxidation conditions.

View Article and Find Full Text PDF

Taper fretting corrosion is considered a potentially limiting factor for total hip arthroplasty longevity. Recently, attention has been focused on new materials for ceramic femoral heads, for example, zirconia-toughened alumina (ZTA), since they have an alternative bearing surface that can improve the wear resistance. Moreover, ceramics have high chemical stability and corrosion resistance.

View Article and Find Full Text PDF

Unlabelled: To overcome serious clinical problems caused by large bone defects, various approaches to bone regeneration have been researched, including tissue engineering, biomaterials, stem cells and drug screening. Previously, we developed a free-standing biodegradable polymer nanosheet composed of poly(L-lactic acid) (PLLA) using a simple fabrication process consisting of spin-coating and peeling techniques. Here, we loaded recombinant human bone morphogenetic protein-2 (rhBMP-2) between two 60-nm-thick PLLA nanosheets, and investigated these sandwich-type nanosheets in bone regeneration applications.

View Article and Find Full Text PDF

Background: We evaluated the clinical and radiographic outcomes, including femoral head penetration, of total hip arthroplasty performed using a specific polyethylene (PE) liner in small Asian patients at 10 years after the index surgery. In addition, we investigated whether femoral head penetration was affected by patient-related, implant-related, and surgical factors.

Methods: Between August 2002 and June 2005, for cementless primary total hip arthroplasty, we used acetabular PE liners that were manufactured from GUR 1050 resin, machined from isostatic compression-molded bar stock, and sterilized with a gamma ray irradiation in argon gas.

View Article and Find Full Text PDF

Younger, active patients who undergo total hip arthroplasty (THA) have increasing needs for wider range of motion and improved stability of the joint. Therefore, bearing materials having not only higher wear resistance but also mechanical strength are required. Carbon fiber-reinforced poly(ether ether ketone) (CFR-PEEK) is known as a super engineering plastic that has great mechanical strength.

View Article and Find Full Text PDF

One of the important factors in determining the success of joint replacement is the wear performance of polyethylene. Although highly crosslinked polyethylene (CLPE) is presently used, it is still not adequate. We have developed a surface modification technology using poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) in an attempt to improve wear performance.

View Article and Find Full Text PDF

To reduce the production of wear particles and subsequent aseptic loosening, we created a human articular cartilage-mimicked surface for a highly cross-linked polyethylene liner, whose surface grafted layer consisted of a biocompatible phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine). Although our previous in vitro findings showed that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted particles were biologically inert and caused no subsequent bone resorptive responses, and poly(2-methacryloyloxyethyl phosphorylcholine) grafting markedly decreased wear in hip joint simulator tests, the clinical safety, and in vivo wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners remained open to question. Therefore, in the present study, we evaluated clinical and radiographic outcomes of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners 5 years subsequent to total hip replacement in 68 consecutive patients.

View Article and Find Full Text PDF

The surface and substrate of a cross-linked polyethylene (CLPE) liner are designed to achieve resistance against oxidative degradation in the construction of hip joint replacements. In this study, we aimed to evaluate the oxidative degradation caused by lipid absorption of a highly hydrophilic nanometer-scaled thickness layer prepared by grafting a poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) layer and a high-dose gamma-ray irradiated CLPE with vitamin E blending (HD-CLPE[VE]). The HD-CLPE(VE) and PMPC-grafted HD-CLPE(VE) exhibited extremely high oxidation resistance regardless of lipid absorption, even though residual-free radical levels were detectable.

View Article and Find Full Text PDF

The wear and creep deformation resistances of polymeric orthopedic bearing materials are both important for extending their longevity. In this study, we evaluated the wear and creep deformation resistances, including backside damage, of different polyethylene (PE) materials, namely, conventional PE, cross-linked PE (CLPE), and poly(2-methacryloyloxyethyl phosphorylcholine)- (PMPC-) grafted CLPE, through wear tests and finite element analysis. The gravimetric and volumetric degrees of wear of disks (3 or 6 mm in thickness) of these materials against a cobalt-chromium-molybdenum alloy pin were examined using a multidirectional pin-on-disk tester.

View Article and Find Full Text PDF

Sterilization using high-energy irradiation is an important aspect of implementing an ultra-high molecular weight polyethylene acetabular liner in total hip arthroplasty (THA). In this study, we evaluate the effects of extra irradiations such as gamma-ray or plasma irradiation during sterilization of the poly(2-methacryloyloxyethyl phosphorylcholine [MPC]) (PMPC) surface and cross-linked polyethylene (CLPE) substrate of a PMPC-grafted CLPE acetabular liner. The PMPC-grafted surface yielded high wettability and low friction properties regardless of the extra irradiations as compared with untreated CLPE.

View Article and Find Full Text PDF

Unlabelled: In the construction of artificial hip joint replacements, the surface and substrate of a cross-linked polyethylene (CLPE) liner are designed to achieve high wear resistance and prevent infection by bacteria. In this study, we fabricated a highly hydrophilic and antibiofouling poly(2-methacryloyloxyethyl phosphorylcholine [MPC]) (PMPC)-graft layer on the vitamin E-blended CLPE (HD-CLPE(VE)) surface. The 100-nm-thick, smooth, and electrically neutral PMPC layer was successfully fabricated on the HD-CLPE(VE) surface using photoinduced graft polymerization.

View Article and Find Full Text PDF

Surface modification by grafting of biocompatible phospholipid polymer onto the surface of artificial joint material has been proposed to reduce the risk of aseptic loosening and improve the durability. Poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted cross-linked polyethylene (CLPE) has shown promising results for reducing wear of CLPE. The main lubrication mechanism for the PMPC layer is considered to be the hydration lubrication.

View Article and Find Full Text PDF

The use of larger femoral heads to prevent the dislocation of artificial hip joints has recently become more common. However, concerns about the subsequent use of thinner polyethylene liners and their effects on wear rate have arisen. Previously, we prepared and evaluated the biological and mechanical effects of a novel highly cross-linked polyethylene (CLPE) liner with a nanometer-scaled graft layer of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC).

View Article and Find Full Text PDF