Objectives: The American Conference of Governmental Industrial Hygienists recommends a threshold limit value-ceiling (TLV-C) of 0.1 ppb for occupational exposure to ortho-phthalaldehyde (OPA) used in washing endoscope probes. To adhere to this extremely low exposure limit, this case study aimed to reduce OPA exposure concentrations of workers during immersion washing of an endoscope probe body.
View Article and Find Full Text PDFBackground: Some organic chemicals are known to cause allergic disorders such as bronchial asthma and hypersensitivity pneumonitis, and it has been considered that they do not cause irreversible pulmonary fibrosis. It has recently been reported, however, that cross-linked acrylic acid-based polymer, an organic chemical, might cause serious interstitial lung diseases, including pulmonary fibrosis. We investigated whether or not intratracheal instillation exposure to cross-linked polyacrylic acid (CL-PAA) can cause lung disorder in rats.
View Article and Find Full Text PDFPreviously, we reported that prenatal exposure to 1-bromopropane (1-BP) causes the accumulation of bromide (Br-) in the brain of rat pups. Here, we aimed to investigate the effects of Br- accumulation in rat pups prenatally exposed to 1-BP vapor. Dam rats were exposed to 1-BP (400 or 700 ppm; 1-BP group) by inhalation, or to NaBr (20 mM; Br- group) in drinking water during gestation days 1-20.
View Article and Find Full Text PDFObjectives: Although 1-Bromopropane (1-BP) exposure has been reported to cause neurotoxicity in adult humans and animals, its effects on the development of the central nervous system remain unclear. Recently, we reported delayed developmental neurotoxicity (DNT) upon 1-BP exposure in rats. Here we aimed to study the effect of prenatal 1-BP exposure on the hippocampal excitability in the juvenile offspring.
View Article and Find Full Text PDFObjectives: The present study aimed to develop a method for measuring the ceiling level of ortho-phthalaldehyde (OPA) exposure and evaluate the ceiling levels of OPA exposure among health care workers who handle disinfectant solutions containing OPA for the disinfection of endoscopes.
Methods: The study consisted of a preliminary survey and main survey. In the preliminary survey, processes involving high-concentration exposure to OPA were identified by video-exposure monitoring (VEM).
Objectives: The purpose of this research was to develop and validate an analytical method for rapid determination of the exposure of workers to ortho-phthalaldehyde (OPA) at the ceiling threshold concentration.
Methods: A 2,4-dinitrophenylhydrazine (DNPH)-silica cartridge was chosen as a sampler. OPA collected by the DNPH-silica cartridge was subsequently extracted with 5 mL of acetonitrile.
Objectives: Neurotoxicity of 1-bromopropane (1-BP) has been reported in occupational exposure, but whether the chemical exerts developmental neurotoxicity is unknown. We studied the effects of prenatal 1-BP exposure on neuronal excitability in rat offspring.
Methods: We exposed dams to 1-BP (700 ppm, 6 h a day for 20 days) and examined hippocampal slices obtained from the male offspring at 2, 5, 8, and 13 weeks of age.
Decomposition characteristics of toluene vapor by titanium dioxide photocatalyst and zeolite that are prepared by thermal spraying on an aluminum fiber filter (photocatalyst filter) were investigated. Toluene vapor was injected into a small chamber made of stainless steel, and an air cleaner equipped with the photocatalyst filter was operated. The vapor concentration in the chamber decreased exponentially.
View Article and Find Full Text PDFObjective: Inhaled 1-bromopropane decomposes easily and releases bromine ion. However, the kinetics and transfer of bromine ion into the next generation have not been clarified. In this work, the kinetics of bromine ion transfer to the next generation was investigated by using cross-fostering analysis and a one-compartment model.
View Article and Find Full Text PDFEquilibrated vapor concentrations at 25°C of the tetrachloroethylene-chlorobenzene system were obtained in the presence of air to establish a method for estimating vapor concentrations in work environments where multicomponent organic solvents are used. The experimental data were correlated by introducing activity coefficients calculated by the UNIFAC (Universal Quasichemical Functional Group Activity Coefficient) model. There were four interaction parameters between groups in this solution system, and three had already been determined.
View Article and Find Full Text PDF1-Bromopropane (1-BP) is used in degreasing solvents and spray adhesives. The adverse effects of 1-BP have been reported in human cases and adult animal models, and its developmental toxicity has also been reported, but its effects on developmental neurotoxicity have not been investigated in detail. We evaluated the effects in rat pups of prenatal exposure to 1-BP on behaviors such as scratching and wet dog shakes (WDS), which were induced by injection of kainate (KA).
View Article and Find Full Text PDFMany volatile organic compounds (VOCs) used in work places are neurotoxic. However, it has been difficult to study the cellular mechanisms induced by a direct exposure to neurons because of their high volatility. The objective of this study was to establish a stable system for exposing brain slices to VOCs.
View Article and Find Full Text PDFObjective: Sensor characteristics and performance of three real-time monitors for volatile organic compounds (VOC monitor) equipped with a photo ionization detector (PID), a sensor using the interference enhanced reflection (IER) method and a semiconductor gas sensor were investigated for 52 organic solvent vapors designated as class 1 and class 2 of organic solvents by the Ordinance of Organic Solvent Poisoning Prevention in Japan.
Methods: Test vapors were prepared by injecting each liquid solvent into a 50 l Tedlar® bag and perfectly vaporizing it. The vapor concentration was from one-tenth to twice the administrative control level for all solvents.
Sangyo Eiseigaku Zasshi
August 2015
Objective: Bacteria on the facepiece of a dust respirator were measured just after use and after 24-hours storage at a room temperature after being worn, and bacteria disinfection methods other than ethanol were examined.
Methods: The existence of bacteria on a facepiece of a mask that had been worn for about one hour in a laboratory was investigated. In order to eliminate bacteria before use on the next day, five methods of bacteria disinfection were investigated: wiping with a facial tissue impregnated with ethanol as a control; wiping with a facial tissue wetted with tap water; wiping with a dry facial tissue after wiping with one wetted with tap water; wiping with a dry facial tissue after wiping with one wetted with distilled water; and wiping with a dry facial tissue two times.
Performance and sensor characteristics of a monitor for volatile organic compounds (VOC monitor) using the interference enhanced reflection (IER) method were investigated for 52 organic solvent vapors that are designated as class 1 and class 2 organic solvents by the Ordinance of Organic Solvent Poisoning Prevention in Japan. Test vapors were prepared by injecting 1 to 3 μl of liquid solvent into a 20 l Tedlar(®) bag and perfectly vaporizing them. The vapor concentration was simultaneously measured with the monitor and a gas chromatograph (GC) equipped with flame ionization detector, and both values were compared.
View Article and Find Full Text PDFMeasurements of organic solvents in the work environment are carried out by either direct sampling using plastic bags/gas chromatography, solid sorbent adsorption using charcoal tubes/gas chromatography, or by a direct reading method using detector tubes. However, these methods cannot always measure the work environment accurately because the concentration of hazardous materials changes from time to time, and from space to space. In this study, the sensor characteristics of a real time monitor using a photoionization detector that can monitor vapor concentration continuously were investigated for 52 organic solvent vapors that are required to be measured in the work environment by the Ordinance of Organic Solvent Poisoning Prevention in Japan.
View Article and Find Full Text PDFObjective: Real time monitoring of total volatile organic compounds (TVOC) in rooms of Japanese university buildings was carried out to understand the temporal changes in actual indoor air quality.
Methods: The TVOC concentrations in seven different rooms, consisting of a lecture room, a seminar room, three laboratories, a computer room and a library, were monitored continuously for 24 h via a personal VOC monitor equipped with a semiconductor gas sensor. An active sampling-thermal desorption method using stainless steel tubes packed with Tenax-TA was also carried out simultaneously to verify the usability of the monitor.
The hood performance of a local exhaust ventilation system is determined by the capture velocity and the air flow rate. The equation proposed by Dalla Valle has been widely used to speculate this relationship. However, Dalla Valle used different formulae for slot and plain opening (rectangular) hoods, and the calculated values near the boundary between the slot and plain opening by these formulae do not always match each other.
View Article and Find Full Text PDFWe measured vapor concentrations continuously evaporated from two-component organic solvents in a reservoir and proposed a method to estimate and predict the evaporation rate or generated vapor concentrations. Two kinds of organic solvents were put into a small reservoir made of glass (3 cm in diameter and 3 cm high) that was installed in a cylindrical glass vessel (10 cm in diameter and 15 cm high). Air was introduced into the glass vessel at a flow rate of 150 ml/min, and the generated vapor concentrations were intermittently monitored for up to 5 hours with a gas chromatograph equipped with a flame ionization detector.
View Article and Find Full Text PDFObjectives: Thermal reconditioning characteristics of organic vapors from a respirator cartridge were studied by introducing humid air into a cartridge that had adsorbed organic vapors in order to develop a thermal reconditioning method.
Methods: Five different organic vapors (methanol, 2-propanol, acetone, dichloromethane and methyl acetate), most of which have relatively weak adsorption affinity to charcoal, were used in this study. Adsorption was carried out at a temperature of 25 degrees C.
1-Bromopropane (1-BP) has been widely used as an alternative to ozone-depleting chlorofluorocarbons in various industries. Although the neurotoxicity of 1-BP has been recently reported, there is little information about the effect of 1-BP on the cells in brain by experimental approach. Here we studied the effect of 1-BP on brain-derived neurotrophic factor (BDNF) expression in astrocytes in vitro.
View Article and Find Full Text PDFIt has been reported that the numbers of people suffering from occupational asthma and skin rashes triggered by various chemicals in indoor air have increased markedly. Two-ethyl-hexanol (2-EH) is known to be an indoor air pollutant and its influence on health is of great concern. However, there are only a few reports regarding its effect on immune cells.
View Article and Find Full Text PDFBioaerosols cause sick building syndrome (SBS) and allergy. Many kinds of bioaerosol impactors are used for measurement of airborne microorganism concentrations in Japan. However, because the impactors are set on agar plates, some microorganisms cannot make colonies on the plates because of their lower viability or demands of nutrition.
View Article and Find Full Text PDFA reduction of the biological half life of toluene in blood in the simultaneous exposure to toluene and alcohol vapors has been reported. To clarify the cause of this reduction, gene expression of CYP mRNA in liver of rats exposed to bi-component organic vapors was investigated. Wistar male rats were repeatedly exposed to 500 ppm of toluene and 300 ppm of 1-butanol vapors individually and simultaneously by inhalation 6 hours a day, five days a week for 4 weeks.
View Article and Find Full Text PDF