Aim: This study aims at developing a nondestructive way for investigating protein adsorption on surfaces such as biomaterials using mass spectrometry.
Methods: Ventricular cerebrospinal fluid in contact with poly carbonate membranes were used as adsorption templates and on-surface enzymatic digestion was applied to desorb proteins and cleave them into peptides. Mass spectrometric analysis provided both protein identification and determination of protein specific adsorption behavior.
This study describes our efforts to study some of the mechanistic aspects of the earlier established on-surface enzymatic digestion (oSED) method. In a multitude of application areas, it has become important to be able to fully characterize and understand selective protein adsorption to biomaterial surfaces for various applications, including biomedicine (implants), nanotechnology (microchip surfaces and sensors) and materials sciences. Herein, the investigation of the mechanistic aspects was based on microdialysis catheter tubes that were flushed with controlled protein solutions mimicking the extracellular fluid of the brain.
View Article and Find Full Text PDFThere is growing interest in using microdialysis (MD) for monitoring larger and more complex molecules such as neuropeptides and proteins. This promotes the use of MD membranes with molecular weight cut off (MWCO) of 100 kDa or above. The hydrodynamic property of the membrane goes to ultrafiltration or beyond, making the MD catheters more sensitive to pressure.
View Article and Find Full Text PDFThis study investigates if deeper understanding is achieved when combining nonlinear and linear chromatographic column characterization methods. As test systems, two hybrid columns (Phenomenex Gemini-NX C18 and Kromasil Eternity C18) and one classic one (Kromasil-C18) were selected. The nonlinear methods were based on firm adsorption theory and involved determination of adsorption isotherms followed by calculations with a new numerical tool, adsorption energy distribution, on probe components at different pH values.
View Article and Find Full Text PDFAn interesting adsorption behavior of racemic methyl mandelate on a tris-(3,5-dimethylphenyl)carbamoyl cellulose chiral stationary phase was theoretically and experimentally investigated. The overloaded band of the more retained enantiomer had a peculiar shape indicating a type V adsorption isotherm whereas the overloaded band of the less retained enantiomer had a normal shape indicating a type I adsorption behavior. For a closer characterization of this separation, adsorption isotherms were determined and analyzed using an approach were Scatchard plots and adsorption energy distribution (AED) calculations are combined for a deeper analysis.
View Article and Find Full Text PDFImportant improvements have recently been made on the elution by characteristic point (ECP) method to increase the accuracy of the determined adsorption isotherms. However, the method has so far been limited/used for only type I adsorption isotherms (e.g.
View Article and Find Full Text PDFThe elution by characteristic points (ECP) method is a very rapid and precise method for determination of the phase system equilibrium of phase systems in broad solute concentration ranges. Thus, the method is especially suitable for rapid characterization of high efficient separation systems. One important source of error, the effects by the post-loop dispersion, was eliminated in a recent investigation.
View Article and Find Full Text PDF