Background: We studied the added value of digital FDG-PET/CT in disease staging and restaging compared to the standard work-up with contrast enhanced CT (ceCT) and CA19-9 in patients with resectable or borderline resectable pancreatic cancer who received neo-adjuvant therapy. Primary endpoints were tumor response compared to ceCT and CA19.9 as well as the ability to detect distant metastatic disease.
View Article and Find Full Text PDFPurpose: Digital PET systems (dPET) improve lesion detectability as compared to PET systems with conventional photomultiplier tubes (cPET). We prospectively studied the performance of high-resolution digital PET scans in patients with cancer, as compared with high- and standard-resolution conventional PET scans, taking the acquisition order into account.
Methods: We included 212 patients with cancer, who were referred for disease staging or restaging.
Int J Comput Assist Radiol Surg
December 2019
Purpose: The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles.
Methods: Image segmentations of CT scans of four patients during inspiration and expiration were used to measure liver and rib displacement.
Purpose: Accurate and precise needle placement is of utmost importance in interventional radiology. However, targeting can be challenging due to, eg, tissue motion and deformation. Steerable needles are a possible solution to overcome these challenges.
View Article and Find Full Text PDFA needle-tissue interaction experiment has been carried out, by inserting the inner needle of a trocar needle into two ex-vivo human livers. The dataset contains the forces that act on the needle during insertion and retraction into the livers. In addition, a MATLAB code file is included that provides base-level analysis of the data and generates force-position diagrams of the needle insertions.
View Article and Find Full Text PDFMedical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference.
View Article and Find Full Text PDFSteering of needles involves the planning and timely modifying of instrument-tissue force interactions to allow for controlled deflections during the insertion in tissue. In this work, the effect of tip shape on these forces was studied using 10 mm diameter needle tips. Six different tips were selected, including beveled and conical versions, with or without pre-bend or pre-curve.
View Article and Find Full Text PDF