Am J Physiol Heart Circ Physiol
January 2025
An increasing number of procedures over the past two decades for aortic stenosis (AS) reflects the combination of an aging population and less invasive transcatheter options. As a result, the hemodynamics of the aortic valve (AV) have gained renewed interest to understand its behavior and to optimize patient selection. We studied the hemodynamic relationship between pressure loss (ΔP) and transvalvular flow (Q) of the normal AV as well as the impact of a variable supravalvular stenosis.
View Article and Find Full Text PDFBackgrounds: Post-dilatation after stenting with a non-compliant (NC) balloon can be used to improve overall percutaneous coronary intervention (PCI) result. Due to lack of evidence on the effect of post-dilatation on adverse clinical endpoints there is no consensus whether post-dilatation should be used routinely. The aim of the current study was to determine the contemporary practice of post-dilatation.
View Article and Find Full Text PDFBackground: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.
Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.
Circ Cardiovasc Interv
January 2025
Background: In the era of first-generation drug-eluting stents and angiography-guided percutaneous coronary intervention (PCI), the presence of a bifurcation lesion was associated with adverse outcomes after PCI. In contrast, the presence of a bifurcation lesion had no impact on outcomes following coronary artery bypass grafting (CABG). Therefore, the presence of a coronary bifurcation lesion requires special attention when choosing between CABG and PCI.
View Article and Find Full Text PDFBackground: Concomitant coronary artery disease (CAD) is highly prevalent in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). The optimal treatment strategy for CAD is a topic of debate. An initial conservative strategy for CAD in patients undergoing TAVI may be favorable as multiple studies have failed to show an evident beneficial effect of percutaneous coronary intervention (PCI) on mortality after TAVI.
View Article and Find Full Text PDFPathogenic variants in the titin gene (TTN) are known to cause a wide range of cardiac and musculoskeletal disorders, with skeletal myopathy mostly attributed to biallelic variants. We identified monoallelic truncating variants (TTNtv), splice site or internal deletions in TTN in probands with mild, progressive axial and proximal weakness, with dilated cardiomyopathy frequently developing with age. These variants segregated in an autosomal dominant pattern in 7 out of 8 studied families.
View Article and Find Full Text PDFBackground: Emergency Medical Services (EMS) studies have shown that prehospital risk stratification and triage decisions in patients with suspected non-ST-elevation acute coronary syndrome (NSTE-ACS) can be improved using clinical risk scores with point-of-care (POC) troponin. In current EMS studies, three different clinical risk scores are used in patients suspected of NSTE-ACS: the prehospital History, ECG, Age, Risk and Troponin (preHEART) score, History, ECG, Age, Risk and Troponin (HEART) score and Troponin-only Manchester Acute Coronary Syndromes (T-MACS). The preHEART score lacks external validation and there exists no prospective comparative analysis of the different risk scores within the prehospital setting.
View Article and Find Full Text PDFBackground: In 5%-25% of non-ST-elevation acute coronary syndrome (NSTE-ACS) patients, coronary angiography reveals no obstructive coronary arteries (MINOCA). Coronary microvascular disease (CMD) is a potential causal pathophysiological mechanism in these patients and can be diagnosed by continuous thermodilution assessment. Recently, the microvascular resistance reserve (MRR) has been introduced as a novel index to assess the vasodilatory capacity of the microcirculation.
View Article and Find Full Text PDFBackground: Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks.
View Article and Find Full Text PDFBackground: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking.
View Article and Find Full Text PDFBackground: Fluid-filled pressure guidewires are unaffected by the previously inevitable hydrostatic pressure gradient (HPG). This study aimed to compare simultaneous pressure measurements with fluid-filled and sensor-tipped pressure guidewires.
Methods: Fifty patients underwent fractional flow reserve (FFR) and P/P measurement with a fluid-filled and a sensor-tipped pressure guidewire simultaneously.
Background: Myocardial ischaemia results from insufficient coronary blood flow. Computed virtual fractional flow reserve (vFFR) allows quantification of proportional flow loss without the need for invasive pressure-wire testing. In the current study, we describe a novel, conductivity model of side branch flow, referred to as 'leak'.
View Article and Find Full Text PDFBackground: There is growing evidence to support the benefits of transcatheter aortic valve implantation (TAVI) over surgical aortic valve replacement (SAVR) in patients with symptomatic severe aortic stenosis (sSAS) who are at high- or intermediate-risk of surgical mortality. The PARTNER 3 trial showed clinical benefits with SAPIEN 3 TAVI compared with SAVR in patients at low risk of surgical mortality. Whether TAVI is also cost-effective compared with SAVR for low-risk patients in the Dutch healthcare system remains uncertain.
View Article and Find Full Text PDFObjective: The corrected left ventricular ejection time (cLVET) comprises the phase from aortic valve opening to aortic valve closure corrected for heart rate. As a surrogate measure for cLVET, the corrected carotid flow time (ccFT) has been proposed in previous research. The aim of this study was to assess the clinical agreement between cLVET and ccFT in a dynamic clinical setting.
View Article and Find Full Text PDFObjectives: Relevant paravalvular leakage (PVL) due to prosthesis dislodgement is a rare but potentially severe complication after transcatheter mitral valve implantation (TMVI). Due to the epicardial anchoring mechanism of the Tendyne® TMVI system, repositioning of the valve stent may be possible by retensioning of the tether. This multicentre study aimed to investigate the procedural and short-term safety as well as efficacy of retensioning manoeuvres.
View Article and Find Full Text PDFMutations in atrial-enriched genes can cause a primary atrial myopathy that can contribute to overall cardiovascular dysfunction. encodes myosin-binding protein H-like (MyBP-HL), an atrial sarcomere protein that shares domain homology with the carboxy-terminus of cardiac myosin-binding protein-C (cMyBP-C). The function of MyBP-HL and the relationship between MyBP-HL and cMyBP-C is unknown.
View Article and Find Full Text PDFAims: Central to the practice of precision medicine in percutaneous coronary intervention (PCI) is a risk-stratification tool to predict outcomes following the procedure. This study is intended to assess machine learning (ML)-based risk models to predict clinically relevant outcomes in PCI and to support individualized clinical decision-making in this setting.
Methods And Results: Five different ML models [gradient boosting classifier (GBC), linear discrimination analysis, Naïve Bayes, logistic regression, and K-nearest neighbours algorithm) for the prediction of 1-year target lesion failure (TLF) were trained on an extensive data set of 35 389 patients undergoing PCI and enrolled in the global, all-comers e-ULTIMASTER registry.