Artificial intelligence (AI) in mammography screening has shown promise in retrospective evaluations, but few prospective studies exist. PRAIM is an observational, multicenter, real-world, noninferiority, implementation study comparing the performance of AI-supported double reading to standard double reading (without AI) among women (50-69 years old) undergoing organized mammography screening at 12 sites in Germany. Radiologists in this study voluntarily chose whether to use the AI system.
View Article and Find Full Text PDFPurpose: To evaluate the association of dynamic enhancement parameters of benign and malignant breast lesions at magnetic resonance (MR) imaging with microvessel distribution and histologic prognostic tumor characteristics.
Materials And Methods: Regional review board approval and informed consent were obtained. Surgical resection specimens of breast lesions (32 benign, 86 malignant) in 118 patients (age range, 28-86 years; mean, 58 years) who had undergone dynamic T1-weighted MR imaging of both breasts were included in the study.
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging.
Materials And Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.
The purpose was to combine T1-weighted 3D gradient echo sequences at low and high spatial resolution (and short and longer acquisition time, respectively) in two orientations without compromising signal/time curve analysis and to evaluate the incremental value of assessing architectural features in high resolution images in dynamic contrast-enhanced MR mammography. T1-weighted 3D-FLASH sequences in a 1.5-T scanner (512 x 256 pixel matrix at high resolution; 256 x 128 pixels at low resolution sequences, 72 slices, 1.
View Article and Find Full Text PDFObjective: The purpose of our study was to assess the prevalence, characteristics, and clinical consequence of incidentally detected enhancing lesions on MRI of the breast. SUBJECTS AND METHODS. MRI of the breast (1.
View Article and Find Full Text PDF