Background: A chloride test is an integral part of a basic metabolic panel that is essential for the assessment of a patient's acid-base and electrolyte status. While many methods are available commercially for the routine measurement of chloride, there is a need to address the accuracy and variability among the measurement results, especially with the prevalence of patients seeking treatment across different healthcare providers for alternative opinions.

Method: A method based on sector field inductively coupled plasma isotope dilution mass spectrometry (SF-ICP-IDMS) was developed for the measurement of chloride in human serum.

View Article and Find Full Text PDF

Objectives: Urine albumin is measured in clinical laboratories by immunoturbidimetry. However, large biases are observed among the different routine methods. To standardize the measurement of urine albumin, a reference measurement procedure (RMP) and urine albumin certified reference materials (CRMs) are needed.

View Article and Find Full Text PDF

A systematic procedure for the determination of purity values of amino acid reference materials was developed by use of mass balance method where four categories of impurities (related structure impurities (RSIs), water, organic solvent residue (OSR), and non-volatile residue (NVR)) were quantified separately. The amount of RSIs was determined using a combination of three quantification methods. To ensure metrological traceability in the determination of RSIs, at least one such impurity in each candidate amino acid reference material was quantified using liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS).

View Article and Find Full Text PDF

Over two decades, the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) has organized a number of comparisons for clinically relevant small molecule organic biomarkers. The aim of the OAWG community is to be part of the coordinated international movement towards accuracy and comparability of clinical measurements that will, in turn, minimize the wastage of repeat testing and unnecessary therapy to create a sustainable healthcare industry. International and regional directives/requirements on metrological traceability of calibrators and control materials are in place.

View Article and Find Full Text PDF

Testosterone in human serum is commonly tested in clinical laboratories using immunoassay methods as well as liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. To standardize and ensure the accuracy of the measurement results, reference procedures with higher metrological order are required. A simple measurement procedure based on one-step liquid-liquid extraction (LLE) and liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) was developed for total testosterone in human serum.

View Article and Find Full Text PDF

Background The measurement of hemoglobin A1c (HbA1c) is important for diagnosing diabetes mellitus as well as assessing glycemic control in diabetic patients. Commutable whole blood certified reference materials (CRMs) are needed in the measurement of HbA1c for method validation and/or as quality controls. Methods We developed three levels of hemolyzed whole blood CRMs for HbA1c.

View Article and Find Full Text PDF

A gas chromatography-isotope dilution mass spectrometry (GC-IDMS) technique was developed for the quantification of two heavy polyaromatic hydrocarbons (PAHs), benz[a]anthracene and benzo[a]pyrene, in yerba maté tea (maté). The optimisation of two extraction methods, namely liquid-liquid extraction and accelerated solvent extraction, was carried out. Both optimised methods were validated using a certified reference material of fine dust and the results were within the expanded uncertainties at 95% confidence level.

View Article and Find Full Text PDF

High accuracy methods were developed for the measurements of calcium, potassium, iron and magnesium in human serum using standard addition and isotope dilution mass spectrometry methods. The results were comparable to those obtained by other national metrology institutes and designated institutes as demonstrated in an inter-laboratory comparison. The methods were then adopted for the assignment of reference values in a human serum material and the uncertainties associated with the certified values were obtained by combining the uncertainty components from the characterisation, homogeneity and long-term stability of the materials.

View Article and Find Full Text PDF

To achieve fast and accurate analysis of carbamazepine in surface water, we developed a novel porous membrane-protected micro-solid-phase extraction (μ-SPE) method, followed by liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) analysis. The μ-SPE device (∼0.8 × 1 cm) was fabricated by heat-sealing edges of a polypropylene membrane sheet to devise a bag enclosing the sorbent.

View Article and Find Full Text PDF

The development of reference measurement methods for hemoglobin A1c (HbA1c) is important for quality assurance in diabetes management. The IFCC reference method using purified proteins as calibration standards is the recommended accuracy-based reference method for the standardization of HbA1c measurement. We developed a highly precise and accurate liquid chromatography-isotope-dilution tandem mass spectrometry (LC-IDMS/MS) procedure, which can serve as an alternative accuracy-based method for HbA1c measurement.

View Article and Find Full Text PDF

Isotope dilution mass spectrometry and standard addition techniques were developed for the analysis of four elements (Ca, As, Cd and Pb) in a mushroom powder material. Results from the validated methods were compared to those of other national metrology institutes in the CCQM-K89 intercomparisons and the results were in excellent agreement with the reference values. The same methods were then used for the assignment of reference values to a mushroom powder Certified Reference Material (CRM).

View Article and Find Full Text PDF

Background: Free glycerol in human serum is measured in clinical laboratories using enzymatic methods, which can be affected by interferences from biological samples. These methods are not applicable when stable isotopic tracers are used to determine lipid kinetics. Hence, a reference measurement procedure for free glycerol in human serum is needed.

View Article and Find Full Text PDF

Determination of total thyroxine in human serum using hollow fiber liquid-phase microextraction (HF-LPME) has been accomplished for the first time. HF-LPME serves as an inexpensive sample pretreatment and the cleanup method that is nearly solvent-free. Thyroxine was extracted through a water immiscible organic solvent immobilized in the wall pores of a polypropylene hollow fiber into 20μl of an aqueous acceptor phase inside the lumen of the hollow fiber.

View Article and Find Full Text PDF

Background: Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published.

View Article and Find Full Text PDF

A high-accuracy double isotope dilution mass spectrometric method using an exact matching approach with GC coupled to a mass spectrometer for the analysis of cyanuric acid in fortified milk powder was developed. Various parameters for sample clean-up such as the type of SPE cartridge, GC column and type of derivatizing agent used were investigated. The method was found to be linear in the concentration range of 0.

View Article and Find Full Text PDF

Background: An isotope dilution mass spectrometry (IDMS) technique has been developed for high accuracy analysis of glucose in human serum. Currently, all the IDMS methods for glucose analysis are based on gas chromatography-mass spectrometry (GC-MS). In this study, isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) was investigated.

View Article and Find Full Text PDF

A GC-high-resolution isotope dilution MS (IDMS) method for the quantification of melamine in milk powder is described. The developed technique is compared to the LC-IDMS/MS technique, typically used for the determination of melamine in various matrices. The accuracy of the GC-high-resolution IDMS method was demonstrated when a small degree of equivalence was obtained in a regional comparative study involving the determination of melamine in milk powder.

View Article and Find Full Text PDF