Publications by authors named "Tong In Oh"

. This focus collection aims at presenting recent advances in electrical impedance tomography (EIT), including algorithms, hardware, and clinical applications..

View Article and Find Full Text PDF

This study aims to find base materials for dry electrode fabrication with high accuracy and without reducing electrode performance for long-term bioelectric potential monitoring after electroless silver plating. Most applications of dry electrodes that have been developed in the past few decades are restricted by low accuracy compared to commercial Ag/AgCl gel electrodes, as in our previous study of PVDF-based dry electrodes. In a recent study, however, nanoweb-based chlorinated polyisoprene (CPI) and poly(styrene--butadiene--styrene) (SBS) rubber were selected as promising candidates due to their excellent elastic properties, as well as their nanofibril nature, which may improve electrode durability and skin contact.

View Article and Find Full Text PDF

For functional reconstruction of fibrocartilage, it is necessary to reproduce the essential mechanical property exhibited by natural fibrocartilage. The distinctive mechanical property of fibrocartilage is originated from the specific histological features of fibrocartilage composed of highly aligned type I collagen (Col I) and an abundant cartilaginous matrix. While the application of tensile stimulation induces highly aligned Col I, our study reveals that it also exerts an antichondrogenic effect on scaffold-free tissues constructed with meniscal chondrocytes (MCs) and induces downregulation of Sox-9 expression and attenuated glycosaminoglycan production.

View Article and Find Full Text PDF

Electrical impedance tomography (EIT) can monitor the real-time hemodynamic state of a conscious and spontaneously breathing patient noninvasively. However, cardiac volume signal (CVS) extracted from EIT images has a small amplitude and is sensitive to motion artifacts (MAs). This study aimed to develop a new algorithm to reduce MAs from the CVS for more accurate heart rate (HR) and cardiac output (CO) monitoring in patients undergoing hemodialysis based on the source consistency between the electrocardiogram (ECG) and the CVS of heartbeats.

View Article and Find Full Text PDF

Conductivity tensor imaging (CTI) using MRI is an advanced method that can non-invasively measure the electrical properties of living tissues. The contrast of CTI is based on underlying hypothesis about the proportionality between the mobility and diffusivity of ions and water molecules inside tissues. The experimental validation of CTI in both and settings is required as a reliable tool to assess tissue conditions.

View Article and Find Full Text PDF

The successful management of cervical intraepithelial neoplasia (CIN) with proper screening and treatment methods could prevent cervical cancer progression. We propose a bioimpedance spectroscopic measurement device and a multi-electrode probe as an independent screening tool for CIN. To evaluate the performance of this screening method, we enrolled 123 patients, including 69 patients with suspected CIN and 54 control patients without cervical dysplasia who underwent a hysterectomy for benign disease (non-CIN).

View Article and Find Full Text PDF

The importance of perioperative respiration monitoring is highlighted by high incidences of postoperative respiratory complications unrelated to the original disease. The objectives of this pilot study were to (1) simultaneously acquire respiration rate (RR), tidal volume (TV), minute ventilation (MV), SpO and PETCO from patients in post-anesthesia care unit (PACU) and (2) identify a practical continuous respiration monitoring method by analyzing the acquired data in terms of their ability and reliability in assessing a patient's respiratory status. Thirteen non-intubated patients completed this observational study.

View Article and Find Full Text PDF

Otitis media is mainly caused by upper respiratory tract infection and eustachian tube dysfunction. If external upper respiratory tract infection is not detected early in the middle ear, or an appropriate immune response does not occur, otitis media can become a chronic state or complications may occur. Therefore, given the important role of Toll-like receptors (TLRs) in the early response to external antigens, we surveyed the role of TLRs in otitis media.

View Article and Find Full Text PDF

Background: To analyze the characteristics of patients with noise-induced hearing loss (NIHL) by comparing audiologic test findings between groups with and without tinnitus.

Methods: This study involved patients with noise-induced hearing loss (NIHL) who presented to the otolaryngology clinic between January 2016 and April 2019. Tests including 3 pure-tone audiometry (PTA) tests at intervals greater than 1 week, and auditory brainstem response (ABR) were evaluated and patients were screened for tinnitus.

View Article and Find Full Text PDF

Literature in the field of stem cell therapy indicates that, when stem cells in a state of single-cell suspension are injected systemically, they show poor in vivo survival, while such cells show robust cell survival and regeneration activity when transplanted in the state of being attached on a biomaterial surface. Although an attachment-deprived state induces anoikis, when cell-surface engineering technology was adopted for stem cells in a single-cell suspension state, cell survival and regenerative activity dramatically improved. The biochemical signal coming from ECM (extracellular matrix) molecules activates the cell survival signal transduction pathway and prevents anoikis.

View Article and Find Full Text PDF

Background: Seismocardiography measures the vibrations produced by the beating heart using an accelerometer sensor placed on the chest. We evaluated the ability of smartphone seismocardiography to distinguish between the presence and absence of spontaneous circulation.

Methods: Seismocardiography signals were obtained using a smartphone placed on the sternum in a convenience sample of 60 adult patients (30 comatose patients with spontaneous circulation and 30 deceased patients).

View Article and Find Full Text PDF

The most frequent causes of tinnitus associated with hearing loss are noise-induced hearing loss and presbycusis. The mechanism of tinnitus is not yet clear, although several hypotheses have been suggested. Therefore, we aimed to analyze characteristics of chronic tinnitus between noise-induced hearing loss and presbycusis.

View Article and Find Full Text PDF

Previous imaging studies have shown the morphological malformation and the alterations of ionic mobility, water contents, electrical properties, or metabolites in seizure brains. Magnetic resonance electrical properties tomography (MREPT) is a recently developed technique for the measurement of electrical tissue properties with a high frequency that provides cellular information regardless of the cell membrane. In this study, we examined the possibility of MREPT as an applicable technique to detect seizure-induced functional changes in the brain of rats.

View Article and Find Full Text PDF
Article Synopsis
  • Doctors measured how much air people breathed in and how much blood their heart pumped while they slept, focusing on patients with sleep problems called OSA (obstructive sleep apnea).
  • They found that during some breathing issues called hypopneas and apneas, the amount of air breathed in decreased a lot, which showed worse breathing during sleep.
  • The study suggests that measuring how much air is breathed in could help understand OSA better, alongside other tests they usually use.
View Article and Find Full Text PDF

Cardiac output (CO) is an important parameter in fluid management decisions for treating hemodynamically unstable patients in intensive care unit. The gold standard for CO measurements is the thermodilution method, which is an invasive procedure with intermittent results. Recently, electrical impedance tomography (EIT) has emerged as a new method for noninvasive measurements of stroke volume (SV).

View Article and Find Full Text PDF

Near the bone remodeling compartments (BRC), extracellular calcium concentration (Ca) is locally elevated and bone marrow stromal cells (BMSCs) close to the BRC can be exposed to high calcium concentration. The calcium-sensing receptor (CaSR) is known to play a key role in maintaining extracellular calcium homeostasis by sensing fluctuations in the levels of extracellular calcium (Ca). When human BMSCs (hBMSCs) were exposed to various calcium concentrations (1.

View Article and Find Full Text PDF

Objective: Meniscus tissue is composed of highly aligned type I collagen embedded with cartilaginous matrix. This histological feature endows mechanical properties, such as tensile strength along the direction of the collagen alignment and endurance to compressive load induced by weight bearing. The main objective of this study was to compare the fibrocartilage construction capability of different cell sources in the presence of mechanical stimuli.

View Article and Find Full Text PDF

Currently, there is no noninvasive method available for simultaneous measurements of tidal volume and stroke volume. Electrical impedance tomography (EIT) has been used for regional lung ventilation imaging. Cardiac EIT imaging, however, has not been successful due to the technical difficulty in extracting weak cardiogenic components.

View Article and Find Full Text PDF

Characterizing upper airway occlusion during natural sleep could be instrumental for studying the dynamics of sleep apnea and designing an individualized treatment plan. In recent years, obstructive sleep apnea (OSA) phenotyping has gained attention to classify OSA patients into relevant therapeutic categories. Electrical impedance tomography (EIT) has been lately suggested as a technique for noninvasive continuous monitoring of the upper airway during natural sleep.

View Article and Find Full Text PDF

Background: Electrical impedance tomography (EIT) has been used for functional lung imaging of regional air distributions during mechanical ventilation in intensive care units (ICU). From numerous clinical and animal studies focusing on specific lung functions, a consensus about how to use the EIT technique has been formed lately. We present an integrated EIT system implementing the functions proposed in the consensus.

View Article and Find Full Text PDF

Microcarrier-based stem cell expansion cultures can increase the dimensions of in vitro stem cell cultures from 2D to 3D. The culture handling process then becomes more efficient compared with conventional 2D cultures. However, the use of spherical plastic microcarriers complicates the monitoring of cell culture.

View Article and Find Full Text PDF

Study Objectives: Real-time monitoring of upper airway collapse during sleep could be instrumental for studies in biomechanics of obstructive sleep apnea (OSA) and selecting individualized treatment modalities. Although some imaging techniques are used under sedated sleep, none are available during the entire natural sleep process. We hypothesized that electrical impedance tomography (EIT) can be used for noninvasive continuous imaging of the upper airway during natural sleep and quantifying upper airway collapse in terms of its size.

View Article and Find Full Text PDF