Publications by authors named "Tomoaki Motoyanagi"

The neutron beam in boron neutron capture therapy (BNCT) exhibits poor directionality and significantly decreasing neutron flux with increasing distance. Therefore, the treatment site must be close to the irradiation aperture. Some patients with head and neck cancer may benefit from a sitting-position setup.

View Article and Find Full Text PDF

Background: Accelerator-based boron neutron capture therapy (AB-BNCT) systems are becoming commercially available and are expected to be widely used in hospitals. To ensure the safety of BNCT, establishing a quality assurance (QA) program and properly managing the stability of the system are necessary. In particular, a high level of beam output stability is required to avoid accidents because beam output is a major factor in patient dose.

View Article and Find Full Text PDF

This study aims to evaluate the feasibility of using a commercially available boron neutron capture therapy (BNCT) dose calculation program (NeuCure Dose Engine) in terms of calculation accuracy and computation time. Treatment planning was simulated under the following calculation parameters: 1.5-5.

View Article and Find Full Text PDF

NeuCure® is the only accelerator-based boron neutron capture therapy (BNCT) system in the world with pharmaceutical approval. Until now, only flat collimators (FCs) on the patient side have been installed. However, in some cases of head and neck cancer patients, positioning the patient close enough to the collimator when using FCs was difficult.

View Article and Find Full Text PDF

We aimed to evaluate dosimetric effects of ipsilateral shoulder position variations (ISPVs) in sitting-positioned boron neutron capture therapy (BNCT) for lower neck tumor. The ISPVs were simulated using deformed shoulder images that can simulate arbitrary shape. The dose-volume parameters for the tumor in the rotated shoulder plans considerably varied compared with that for the mucosa.

View Article and Find Full Text PDF

The irradiation field of boron neutron capture therapy (BNCT) consists of multiple dose components including thermal, epithermal and fast neutron, and gamma. The objective of this work was to establish a methodology of dosimetric quality assurance (QA), using the most standard and reliable measurement methods, and to determine tolerance level for each QA measurement for a commercially available accelerator-based BNCT system. In order to establish a system of dosimetric QA suitable for BNCT, the following steps were taken.

View Article and Find Full Text PDF

The dosimetric effect of set-up error in boron neutron capture therapy (BNCT) for head and neck cancer remains unclear. In this study, we analyzed the tendency of dose error by treatment location when simulating the set-up error of patients. We also determined the tolerance level of the set-up error in BNCT for head and neck cancer.

View Article and Find Full Text PDF

In recent years, a novel technique has been employed to maintain a distance between the prostate and the rectum by transperineally injecting a hydrogel spacer (HS). However, the effect of HS on the prostate positional displacement is poorly understood, despite its stability with HS in place. In this study, we investigated the effect of HS insertion on the interfraction prostate motion during the course of proton therapy (PT) for Japanese prostate cancer patients.

View Article and Find Full Text PDF

Installation of an accelerator-based boron neutron capture therapy (AB-BNCT) system was started in April 2014 at the Southern Tohoku BNCT Research Center (STBRC), and clinical trials began in January 2016. There are two treatment rooms, which have same specifications, and the beam quality equivalency was confirmed both rooms. Here, we describe the design and construction of the first hospital-based AB-BNCT facility in the world with multiple treatment rooms.

View Article and Find Full Text PDF