This work involves the novel use of a radio telemetry-based system that continuously monitors phosphine using two different types of electrochemical detectors (ECD/RT). The ECD/RT units were used to monitor phosphine inside and at varying distances from large tobacco storage warehouses. A master controller unit transferred the data to a personal computer that received and displayed the data.