Publications by authors named "Tomas Mraz"

We herein present a case study of a patient with heart failure with a preserved ejection fraction and severe symptoms who underwent interatrial shunt device implantation and follow-up at a tertiary care heart failure clinic. The interatrial shunt device implantation was successful. No adverse events occurred, and the device prevented hospitalization for heart failure during long-term follow-up.

View Article and Find Full Text PDF

Objectives: This is a first report of the safety and 1-year outcomes of left atrial appendage closure (LAAC) using a novel foam-based conformable device, guided by intracardiac echocardiography (ICE).

Background: Limitations of current transcatheter LAAC devices include the need for precise coaxial delivery into the left atrial appendage (LAA), potential for traumatic implantation, incomplete LAA seal, and device-related thrombus.

Methods: The device (Conformal Left Atrial Appendage Seal, Conformal Medical Inc) is a self-expanding occluder consisting of a cylindrical nitinol endoskeleton with low-profile anchor barbs around the midpoint, covered with a porous foam cup.

View Article and Find Full Text PDF

The evidence supporting surgical aneurysmectomy in ischemic heart failure is inconsistent. The aim of the study was to describe long-term effect of minimally invasive hybrid transcatheter and minithoracotomy left ventricular (LV) reconstruction in patients with ischemic cardiomyopathy. Twenty-three subjects with transmural anterior wall scarring, LV ejection fraction 15-45%, and New York Heart Association class ≥ II were intervened using Revivent TC anchoring system.

View Article and Find Full Text PDF

Background: The next-generation Watchman FLX left atrial appendage closure (LAAC) device has: (1) an atraumatic closed distal end, (2) reduced height, (3) a recessed screw hub to decrease device-related thrombus (DRT), (4) two rows of J-shape anchors so redeployment is possible after full recapture, and (5) ability to treat a greater size range of LAA ostia.

Objective: To report, for the first time, the feasibility and safety of intracardiac echocardiography (ICE)-guided Watchman FLX implantation.

Methods: A single-center prospective registry of atrial fibrillation patients planned for LAAC with the FLX device underwent ICE-guided implantation with conscious sedation.

View Article and Find Full Text PDF

Background: Many patients requiring a pacemaker have persistent hypertension with systolic blood pressures above recommended levels. We evaluated a pacemaker-based Programmable Hypertension Control (PHC) therapy that uses a sequence of variably timed shorter and longer atrioventricular intervals.

Methods And Results: Patients indicated for dual-chamber pacing with office systolic blood pressure (oSBP) >150 mm Hg despite stable medical therapy were implanted with a Moderato™ pulse generator that delivers PHC therapy.

View Article and Find Full Text PDF

Study Objective: To compare parameters of diastolic function as assessed by radionuclide ventriculography (RNVG) and Doppler echocardiography (ECHO) in the patients with chronic heart failure and reduced ejection fraction (HF REF).

Patients And Methods: RNVG and ECHO were performed on the same day in 40 patients with systolic chronic HF, NYHA II and III, with LV EF < 50 % and sinus rhythm, followed at tertiary HF clinic. Diastolic function was assessed by RNVG using parameters: PFR (peak filling rate [% SV/sec]), TFR - time to peak filling rate (ms), and by ECHO using pulse Doppler parameters: the peak Doppler velocities of early (E) and late diastolic flow (A), the E/A ratio, the calculated mean of the early (E´) diastolic velocity of septal and lateral mitral annulus measured by tissue Doppler imaging, and the E/E´ ratio.

View Article and Find Full Text PDF

Background: Percutaneous approaches to left atrial appendage (LAA) closure are being developed for stroke prophylaxis in atrial fibrillation patients as an alternative to warfarin. Non-randomized clinical trials suggested that the first of these devices, the percutaneous left atrial appendage transcatheter occlusion (PLAATO) device, is safe and reduces stroke risk. Percutaneous closure has the potential limitation of incomplete exclusion of LAA from the systemic circulation, which could potentially lead to thrombus formation and stroke.

View Article and Find Full Text PDF

Aims: To assess the reproducibility of tissue Doppler myocardial velocities in patients with dilated ventricles and markedly reduced systolic function (ejection fraction <35%).

Methods And Results: Forty-one patients referred for cardiac resynchronization therapy (CRT) were evaluated using tissue Doppler echocardiography. The inter and intra-individual reproducibility of peak systolic myocardial velocities and the intra-ventricular delay in three apical projections was assessed by repeated evaluation of each registered data set.

View Article and Find Full Text PDF

Background: Over 90% of thrombi in atrial fibrillation (AF) originate from the left atrial appendage (LAA). Patients with contraindications to anticoagulation are potential candidates for LAA occlusion using the Percutaneous Left Atrial Appendage Transcatheter Occlusion system (PLAATO, ev3 Inc., Plymouth, MN).

View Article and Find Full Text PDF

Unlabelled: Percutaneous occlusion of the left atrial appendage (LAA) is a modern alternative for the treatment of patients with atrial fibrillation (AF) and with a high risk of stroke who are not eligible for long-term anticoagulation therapy. Echocardiography plays a significant role in selecting patients, guiding the procedure, and in the post-procedural follow-up.

Objectives And Methods: To test the role of transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) in facilitating and shortening the procedure.

View Article and Find Full Text PDF