Perfluorooctanoic acid (PFOA) is a persistent organic pollutant that accumulates in the human body, leading to major health issues. Upon oral uptake, the gastrointestinal tract is the first biological barrier against PFOA. However, the localization of PFOA and its impact on the intestinal wall are largely unknown.
View Article and Find Full Text PDFAdvanced characterization is paramount to understanding battery cycling and degradation in greater detail. Herein, we present a novel methodology of battery electrode analysis, employing focused ion beam (FIB) secondary-ion mass spectrometry platforms coupled with a specific lift-out specimen preparation, allowing us to optimize analysis and prevent air contamination. Correlative microscopy, combining electron microscopy and chemical imaging of a liquid electrolyte Li-ion battery electrode, is performed over the entire electrode thickness down to subparticle domains.
View Article and Find Full Text PDFCompositional engineering of organic-inorganic metal halide perovskite allows for improved optoelectrical properties, however, phase segregation occurs during crystal nucleation and limits perovskite solar cell device performance. Herein, we show that by applying tetrabutylammonium bistriflimide as an additive in the perovskite precursor solution, ultra-uniform perovskite crystals are obtained, which effectively increases device performance. As a result, power conversion efficiencies (PCEs) of 24.
View Article and Find Full Text PDFThe technique of alloying FA with Cs is often used to promote structural stabilization of the desirable α-FAPbI phase in halide perovskite devices. However, the precise mechanisms by which these alloying approaches improve the optoelectronic quality and enhance the stability have remained elusive. In this study, we advance that understanding by investigating the effect of cationic alloying in CsFAPbI perovskite thin-films and solar-cell devices.
View Article and Find Full Text PDFPerovskite solar cells (PSCs) are among the most promising photovoltaic technologies owing to their exceptional optoelectronic properties. However, the lower efficiency, poor stability and reproducibility issues of large-area PSCs compared with laboratory-scale PSCs are notable drawbacks that hinder their commercialization. Here we report a synergistic dopant-additive combination strategy using methylammonium chloride (MACl) as the dopant and a Lewis-basic ionic-liquid additive, 1,3-bis(cyanomethyl)imidazolium chloride ([Bcmim]Cl).
View Article and Find Full Text PDFScanning transmission ion microscopy imaging was performed whilst using a delay-line detector to record the impact position and arrival time of transmitted ions or neutrals. The incident helium ion beam had an energy of 20 keV and the arrival time measurements were used to calculate the energy loss after transmission through the sample. The 5D dataset thus produced (2D position in the sample plane, 2D position in the detector plane, and energy) is analyzed by collection into energy spectra or images.
View Article and Find Full Text PDFThe global transition from fossil fuels to green energy underpins the need for efficient and reliable energy storage systems. Advanced analysis and characterization of battery materials is not only important to understand fundamental battery properties but also crucial for their continued development. A deep understanding of these systems is often difficult to obtain through only pre- and/or post-mortem analyses, with the full complexity of a battery being hidden in its operational state.
View Article and Find Full Text PDFCorrelative microscopy approaches are attracting considerable interest in several research fields such as materials and battery research. Recent developments regarding X-ray computer tomography have made this technique available in a compact module for scanning electron microscopes (SEMs). Nano-computed tomography (nanoCT) allows morphological analysis of samples in a nondestructive way and to generate 2D and 3D overviews.
View Article and Find Full Text PDFDetection of iron at the subcellular level in order to gain insights into its transport, storage, and therapeutic prospects to prevent cytotoxic effects of excessive iron accumulation is still a challenge. Nanoscale magnetic sector secondary ion mass spectrometry (SIMS) is an excellent candidate for subcellular mapping of elements in cells since it provides high secondary ion collection efficiency and transmission, coupled with high-lateral-resolution capabilities enabled by nanoscale primary ion beams. In this study, we developed correlative methodologies that implement SIMS high-resolution imaging technologies to study accumulation and determine subcellular localization of iron in alveolar macrophages.
View Article and Find Full Text PDFThe structural, morphological, and chemical characterization of samples is of utmost importance for a large number of scientific fields. Furthermore, this characterization very often needs to be performed in three dimensions and at length scales down to the nanometer. Therefore, there is a stringent necessity to develop appropriate instrumentational solutions to fulfill these needs.
View Article and Find Full Text PDFNanoparticles occur in various environments as a consequence of man-made processes, which raises concerns about their impact on the environment and human health. To allow for proper risk assessment, a precise and statistically relevant analysis of particle characteristics (such as size, shape, and composition) is required that would greatly benefit from automated image analysis procedures. While deep learning shows impressive results in object detection tasks, its applicability is limited by the amount of representative, experimentally collected and manually annotated training data.
View Article and Find Full Text PDFA newly developed microscope prototype, namely npSCOPE, consisting of a Gas Field Ion Source (GFIS) column and a position sensitive Delay-line Detector (DLD) was used to perform Scanning Transmission Ion Microscopy (STIM) using keV He ions. One experiment used 25 keV ions and a second experiment used 30 keV ions. STIM imaging of a 50 nm thick free-standing gold membrane exhibited excellent contrast due to ion channelling and revealed rich microstructural features including isolated nanoscale twin bands which matched well with the contrast in the conventional ion-induced Secondary Electron (SE) imaging mode.
View Article and Find Full Text PDFOver the last few decades, nanoparticles have become a key element in a number of scientific and technological fields, spanning from materials science to life sciences. The characterization of nanoparticles or samples containing nanoparticles, in terms of morphology, chemical composition, and other parameters, typically involves investigations with various analytical tools, requiring complex workflows and extending the duration of such studies to several days or even weeks. Here, we report on the development of a new unique in situ correlative instrument, allowing us to answer questions about the shape, size, size distribution, and chemical composition of the nanoparticles using a single probe.
View Article and Find Full Text PDFThis paper is a review on the combination between Helium Ion Microscopy (HIM) and Secondary Ion Mass Spectrometry (SIMS), which is a recently developed technique that is of particular relevance in the context of the quest for high-resolution high-sensitivity nano-analytical solutions. We start by giving an overview on the HIM-SIMS concept and the underlying fundamental principles of both HIM and SIMS. We then present and discuss instrumental aspects of the HIM and SIMS techniques, highlighting the advantage of the integrated HIM-SIMS instrument.
View Article and Find Full Text PDFThe development of high-resolution microscopy and spectroscopy techniques has allowed the analysis of microscopic 3D objects in fields like nanotechnology and life and soil sciences. Soils have the ability to incorporate and store large amounts of organic carbon. To study this organic matter (OM) sequestration, it is essential to analyze its association with soil minerals at the relevant microaggregate scale.
View Article and Find Full Text PDFA detection system based on a microchannel plate with a delay line readout structure has been developed to perform scanning transmission ion microscopy (STIM) in the helium ion microscope (HIM). This system is an improvement over other existing approaches since it combines the information of the scanning beam position on the sample with the position (scattering angle) and time of the transmission events. Various imaging modes, such as bright field and dark field or the direct image of the transmitted signal, can be created by post-processing the collected STIM data.
View Article and Find Full Text PDFOff-stoichiometric copper chromium delafossites demonstrate the highest values of electric conductivity among the p-type transparent conducting oxides. Morphological and structural changes in CuCrO upon annealing processes are investigated. Chained copper vacancies were previously suggested as source of the high levels of doping in this material.
View Article and Find Full Text PDFZnO nanobelts may grow with their polar axis perpendicular to growth direction. Heterostructured nanobelts therefore contain hetero-interfaces along the polar axis of ZnO where polarisation mismatch may induce electron confinement. These interfaces run along the length of the nanobelts.
View Article and Find Full Text PDFA dedicated transmission helium ion microscope (THIM) for sub-50 keV helium has been constructed to investigate ion scattering processes and contrast mechanisms, aiding the development of new imaging and analysis modalities. Unlike a commercial helium ion microscope (HIM), the in-house built instrument allows full flexibility in experimental configuration. Here, we report projection imaging and intensity patterns obtained from powder and bulk crystalline samples using stationary broad-beam as well as convergent-beam illumination conditions in THIM.
View Article and Find Full Text PDFBackground: The present study aimed to evaluate the potential differences in the biological effects of two types of spherical silver particles of 20 and 200 nm (Ag20 and Ag200), and of PVP-coated silver nanowires (AgNWs) with a diameter of 50 nm and length up to 50 μm, using a complex 3D model representative for the alveolar barrier cultured at air-liquid interface (ALI). The alveolar model was exposed to 0.05, 0.
View Article and Find Full Text PDFThe helium ion microscope (HIM) has emerged as an instrument of choice for patterning, imaging and, more recently, analytics at the nanoscale. Here, we review secondary electron imaging on the HIM and the various methodologies and hardware components that have been developed to confer analytical capabilities to the HIM. Secondary electron-based imaging can be performed at resolutions down to 0.
View Article and Find Full Text PDFThe chemical or elemental analysis of samples with complex surface topography is challenging for secondary ion mass spectrometry (SIMS), if the three-dimensional structure of the sample is not taken into account. Conventional 3D reconstruction of SIMS data assumes a flat surface and uniform sputtering conditions, which is not the case for many analytical applications involving micro- and nanosized particles, composites, or patterned materials. Reliable analysis of such samples requires knowledge of the actual 3D surface structure to correctly reconstruct the SIMS 3D maps.
View Article and Find Full Text PDFThe mechanical, structural, electronic and magnetic properties of carbon nanotubes can be modified by electron or ion irradiation. In this work we used 25 keV He and Ne ion irradiation to study the influence of fluence and sample thickness on the irradiation-induced damage of multiwalled carbon nanotubes (MWCNTs). The irradiated areas have been characterised by correlative Raman spectroscopy and TEM imaging.
View Article and Find Full Text PDFUnderstanding the localisation and abundance of structural elements, trace elements and especially transition metals like Cu and Zn in ocular tissue sections is important for physiology, and also for the characterisation of diseases related to oxidative stress like age-related macular degeneration. Transition metal abundances were investigated in an aged donor eye by nano-secondary ion mass spectrometry (nano-SIMS) elemental mapping using Cs and O primary ions, respectively, and correlated to their respective mole fractions investigated by analytical electron microscopy (AEM). The ultrastructure of the tissue and the elemental composition of melanosomes of the choroid and RPE, and RPE lipofuscin and melanolipofuscin granules can adequately be investigated by nano-SIMS using the secondary ion maps.
View Article and Find Full Text PDF