Background: Monitoring heparin concentration along with the activated clotting time (ACT) may provide a more accurate guide for the administration of heparin to infants during cardiopulmonary bypass (CPB). However, standard laboratory assays of heparin concentration (antifactor Xa heparin concentration) require plasma instead of whole blood, and results are not immediately available to clinicians. Alternatively, measurements of whole blood heparin concentration may be performed at the bedside using an automated protamine titration device, the Hepcon instrument (Hepcon Hemostasis Management System Plus; Medtronics, Minneapolis, MN).
View Article and Find Full Text PDFBackground: Recent concern about the safety of aprotinin administration to adults has led to its suspension from worldwide markets. However, few studies have examined its safety in pediatric patients. Studies in children evaluating aprotinin's safety have been hindered by the heterogeneity of pediatric patients and the inconsistency of clinical protocols.