Purpose: To evaluate differences in straylight between eyes implanted with a hydrophilic multifocal IOL (Seelens MF; Hanita Lenses, Hanita, Israel) and a hydrophobic multifocal IOL (SN6AD1; Alcon Laboratories, Inc., Fort Worth, TX).
Methods: In a prospective cohort study, routinely obtained straylight measurements (C-Quant; Oculus Optikgeräte, Wetzlar, Germany) 3 months after standard phacoemulsification for either cataract or refractive lens procedures were compared.
Purpose: To evaluate the effect of vitreous floaters on intraocular straylight.
Methods: Records of bilaterally phakic patients with unilateral complaint of floaters as the main symptom were identified from an electronic database. Patients who underwent straylight measurements on both affected and unaffected eyes using a C-Quant straylight meter were selected.
Purpose: To compare the quality of vision (straylight and contrast sensitivity) after femtosecond laser-assisted Descemet stripping endothelial keratoplasty (FS DSEK) and penetrating keratoplasty (PK).
Design: Prospective, randomized clinical trial.
Methods: setting: Multicenter (5 ophthalmic centers in The Netherlands).
In a patient with complaints of photophobia and an ocular deviation, straylight was found to be increased to 1.61 (log[s]), which is 5 times the normal value. The only relative clinical finding was the edge of a too small posterior capsulotomy.
View Article and Find Full Text PDFPurpose: In a double-masked randomized controlled crossover study we investigated both the retinal responses to straylight, and the effects of lens cleaners on straylight values, in two different RGP contact lens materials.
Methods: Thirty patients (20-59 years) wearing RGP lenses were refitted with new lenses made of Boston XO material in one eye and made of Comfort O2 (ONSI-56) material in the other eye. Reported wetting angles for the Boston XO material (103 degrees ) and for the ONSI-56 material (7.
Purpose: To measure intraocular straylight (as a measure of glare) after cataract surgery and implantation of an AcrySof ReSTOR SA60D3 multifocal or AcrySof SA60AT monofocal intraocular lens (IOL) (both Alcon Laboratories).
Setting: University Hospital Maastricht, Maastricht; Isala Clinics, Zwolle; Netherlands Institute for Neurosciences, Amsterdam, The Netherlands.
Methods: In a prospective open observational case series, a newly developed straylight meter was used to objectively measure straylight 6 months postoperatively in 66 eyes with a diffractive AcrySof ReSTOR SA60D3 IOL (multifocal group) and 40 eyes with a monofocal AcrySof SA60AT IOL (monofocal group).
J Opt Soc Am A Opt Image Sci Vis
July 2004
We developed an algorithm that directly determines Zernike coefficients for the corneal anterior surface derived from the reflection image of a stimulus with pseudorandom encoding. This algorithm does not need to include calculation of corneal height maps. The numerical performance of the algorithm is good.
View Article and Find Full Text PDF