Publications by authors named "Tolstikova A"

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework.

View Article and Find Full Text PDF
Article Synopsis
  • The main protease (M) of SARS-CoV-2 is crucial for the virus's functionality and is considered a potential target for drug development, as it is only active in its reduced form.
  • When oxidized, M's activity halts but can be restored, indicating an evolutionary adaptation to oxidative environments, although the protective mechanisms haven't been fully elucidated.
  • Researchers determined the crystal structure of oxidized M, revealing a disulfide bond that affects its dimer stability and crystallization, providing insights into the protein's response to oxidative stress and its structural study conditions.*
View Article and Find Full Text PDF

Serial crystallography (SX) has become an established technique for protein structure determination, especially when dealing with small or radiation-sensitive crystals and investigating fast or irreversible protein dynamics. The advent of newly developed multi-megapixel X-ray area detectors, capable of capturing over 1000 images per second, has brought about substantial benefits. However, this advancement also entails a notable increase in the volume of collected data.

View Article and Find Full Text PDF

For decades, researchers have elucidated essential enzymatic functions on the atomic length scale by tracing atomic positions in real-time. Our work builds on possibilities unleashed by mix-and-inject serial crystallography (MISC) at X-ray free electron laser facilities. In this approach, enzymatic reactions are triggered by mixing substrate or ligand solutions with enzyme microcrystals.

View Article and Find Full Text PDF

For decades, researchers have been determined to elucidate essential enzymatic functions on the atomic lengths scale by tracing atomic positions in real time. Our work builds on new possibilities unleashed by mix-and-inject serial crystallography (MISC) at X-ray free electron laser facilities. In this approach, enzymatic reactions are triggered by mixing substrate or ligand solutions with enzyme microcrystals .

View Article and Find Full Text PDF

NendoU from SARS-CoV-2 is responsible for the virus's ability to evade the innate immune system by cleaving the polyuridine leader sequence of antisense viral RNA. Here we report the room-temperature structure of NendoU, solved by serial femtosecond crystallography at an X-ray free-electron laser to 2.6 Å resolution.

View Article and Find Full Text PDF

With advances in X-ray free-electron lasers (XFELs), serial femtosecond crystallography (SFX) has enabled the static and dynamic structure determination for challenging proteins such as membrane protein complexes. In SFX with XFELs, the crystals are typically destroyed after interacting with a single XFEL pulse. Therefore, thousands of new crystals must be sequentially introduced into the X-ray beam to collect full data sets.

View Article and Find Full Text PDF

Multimeric protein assemblies are abundant in nature. Streptavidin is an attractive protein that provides a paradigm system to investigate the intra- and intermolecular interactions of multimeric protein complexes. Also, it offers a versatile tool for biotechnological applications.

View Article and Find Full Text PDF

Serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) enables essentially radiation-damage-free macromolecular structure determination using microcrystals that are too small for synchrotron studies. However, SFX experiments often require large amounts of sample in order to collect highly redundant data where some of the many stochastic errors can be averaged out to determine accurate structure-factor amplitudes. In this work, the capability of the Swiss X-ray free-electron laser (SwissFEL) was used to generate large-bandwidth X-ray pulses [Δλ/λ = 2.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on how enzymes interact with substrates or ligands in real time, specifically observing the first phase of the reaction using advanced imaging techniques.* -
  • Researchers utilized the European XFEL (EuXFEL) to achieve near-atomic resolution and track ceftriaxone binding to β-lactamase, combining high repetition rates and mix-and-inject technology for time-resolved measurements.* -
  • The findings included calculating a diffusion coefficient to understand concentrations in enzyme crystals over time and describing the binding of the inhibitor sulbactam, showcasing the potential of EuXFEL for biomedical research.*
View Article and Find Full Text PDF

The COVID-19 pandemic has resulted in 198 million reported infections and more than 4 million deaths as of July 2021 (covid19.who.int).

View Article and Find Full Text PDF
Article Synopsis
  • COVID-19, caused by SARS-CoV-2, is a severe global health crisis with no direct treatment available.
  • Researchers conducted a high-throughput x-ray crystallography screen on repurposed drug libraries targeting the virus's main protease, which is crucial for its replication.
  • They identified 37 compounds that bind to the protease and found two promising allosteric binding sites, with several compounds showing antiviral activity without toxicity in further tests.
View Article and Find Full Text PDF

A crystallographic indexing algorithm, pinkIndexer, is presented for the analysis of snapshot diffraction patterns. It can be used in a variety of contexts including measurements made with a monochromatic radiation source, a polychromatic source or with radiation of very short wavelength. As such, the algorithm is particularly suited to automated data processing for two emerging measurement techniques for macromolecular structure determination: serial pink-beam X-ray crystallography and serial electron crystallography, which until now lacked reliable programs for analyzing many individual diffraction patterns from crystals of uncorrelated orientation.

View Article and Find Full Text PDF

The new European X-ray Free-Electron Laser (European XFEL) is the first X-ray free-electron laser capable of delivering intense X-ray pulses with a megahertz interpulse spacing in a wavelength range suitable for atomic resolution structure determination. An outstanding but crucial question is whether the use of a pulse repetition rate nearly four orders of magnitude higher than previously possible results in unwanted structural changes due to either radiation damage or systematic effects on data quality. Here, separate structures from the first and subsequent pulses in the European XFEL pulse train were determined, showing that there is essentially no difference between structures determined from different pulses under currently available operating conditions at the European XFEL.

View Article and Find Full Text PDF

The European XFEL (EuXFEL) is a 3.4-km long X-ray source, which produces femtosecond, ultrabrilliant and spatially coherent X-ray pulses at megahertz (MHz) repetition rates. This X-ray source has been designed to enable the observation of ultrafast processes with near-atomic spatial resolution.

View Article and Find Full Text PDF

Reliable sample delivery and efficient use of limited beam time have remained bottlenecks for serial crystallography (SX). Using a high-intensity polychromatic X-ray beam in combination with a newly developed charge-integrating JUNGFRAU detector, we have applied the method of fixed-target SX to collect data at a rate of 1 kHz at a synchrotron-radiation facility. According to our data analysis for the given experimental conditions, only about 3 000 diffraction patterns are required for a high-quality diffraction dataset.

View Article and Find Full Text PDF

Serial crystallography records still diffraction patterns from single, randomly oriented crystals, then merges data from hundreds or thousands of them to form a complete data set. To process the data, the diffraction patterns must first be indexed, equivalent to determining the orientation of each crystal. A novel automatic indexing algorithm is presented, which in tests usually gives significantly higher indexing rates than alternative programs currently available for this task.

View Article and Find Full Text PDF
Article Synopsis
  • The European X-ray Free-Electron Laser (XFEL) is the first of its kind to deliver X-ray pulses at megahertz pulse rates, vastly improving on previous technologies.
  • Researchers have successfully measured high-quality diffraction data at these new pulse rates, validating the laser's capabilities.
  • Two complete datasets were collected: one from lysozyme and another from a β-lactamase complex, demonstrating the potential for advanced structural analysis and dynamic measurements in molecular science.
View Article and Find Full Text PDF

High-resolution Bragg diffraction from aerosolized single granulovirus nanocrystals using an X-ray free-electron laser is demonstrated. The outer dimensions of the in-vacuum aerosol injector components are identical to conventional liquid-microjet nozzles used in serial diffraction experiments, which allows the injector to be utilized with standard mountings. As compared with liquid-jet injection, the X-ray scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid.

View Article and Find Full Text PDF

Unravelling the interaction of biological macromolecules with ligands and substrates at high spatial and temporal resolution remains a major challenge in structural biology. The development of serial crystallography methods at X-ray free-electron lasers and subsequently at synchrotron light sources allows new approaches to tackle this challenge. Here, a new polyimide tape drive designed for mix-and-diffuse serial crystallography experiments is reported.

View Article and Find Full Text PDF

Serial X-ray crystallography allows macromolecular structure determination at both X-ray free electron lasers (XFELs) and, more recently, synchrotron sources. The time resolution for serial synchrotron crystallography experiments has been limited to millisecond timescales with monochromatic beams. The polychromatic, "pink", beam provides a more than two orders of magnitude increased photon flux and hence allows accessing much shorter timescales in diffraction experiments at synchrotron sources.

View Article and Find Full Text PDF

The angiotensin II receptors ATR and ATR serve as key components of the renin-angiotensin-aldosterone system. ATR has a central role in the regulation of blood pressure, but the function of ATR is unclear and it has a variety of reported effects. To identify the mechanisms that underlie the differences in function and ligand selectivity between these receptors, here we report crystal structures of human ATR bound to an ATR-selective ligand and to an ATR/ATR dual ligand, capturing the receptor in an active-like conformation.

View Article and Find Full Text PDF
Article Synopsis
  • Serial femtosecond crystallography relies on efficient delivery of fresh crystals to an X-ray free-electron laser during experiments.
  • A new double-flow focusing nozzle has been developed that reduces sample consumption and enhances jet stability compared to earlier models.
  • This nozzle successfully determined the first room-temperature structure of RNA polymerase II and was tested on other protein samples, including an extradiol ring-cleaving dioxygenase.
View Article and Find Full Text PDF

Mix-and-inject serial crystallography (MISC) is a technique designed to image enzyme catalyzed reactions in which small protein crystals are mixed with a substrate just prior to being probed by an X-ray pulse. This approach offers several advantages over flow cell studies. It provides (i) room temperature structures at near atomic resolution, (ii) time resolution ranging from microseconds to seconds, and (iii) convenient reaction initiation.

View Article and Find Full Text PDF