Publications by authors named "Tohid Pirbodaghi"

Biocompatible microparticles are valuable tools in biomedical research for applications such as drug delivery, cell transplantation therapy, and analytical assays. However, their translation into clinical research and the pharmaceutical industry has been slow due to the lack of techniques that can produce microparticles with controlled physicochemical properties at high throughput. We introduce a robust microfluidic platform for the production of relatively homogeneous microdroplets at a generation frequency of up to 3.

View Article and Find Full Text PDF

Nowadays, sacrificing animals to develop medical devices and receive regulatory approval has become more common, which increases ethical concerns. Although in vivo tests are necessary for development and evaluation of new devices, nonetheless, with appropriate in vitro setups and mathematical models, a part of the validation process can be performed using these models to reduce the number of sacrificed animals. The main aim of this study is to present a mathematical model simulating the hydrodynamic function of a rotary blood pump (RBP) in a pulsatile in vitro flow environment.

View Article and Find Full Text PDF

The widespread application of microfluidic devices in the biological and chemical sciences requires the implementation of complex designs and geometries, which in turn leads to atypical fluid dynamic phenomena. Accordingly, a complete understanding of fluid dynamics in such systems is key in the facile engineering of novel and efficient analytical tools. Herein, we present an accurate approach for studying the fluid dynamics of rapid processes within microfluidic devices using bright-field microscopy with white light illumination and a standard high-speed camera.

View Article and Find Full Text PDF

Axial (AX) and centrifugal (CFG) rotary blood pumps have gained clinical acceptance for the treatment of advanced heart failure. Differences between AX and CFG designs and mechanism of blood flow delivery may offer clinical advantages. In this study, pump characteristics, and acute physiologic responses during support with AX (HeartMate II) and CFG (HVAD) left ventricular assist devices (LVAD) were investigated in mock loop and chronic ischemic heart failure bovine models.

View Article and Find Full Text PDF

In the event of left ventricular assist device (LVAD) failure, we hypothesized that rotary blood pumps will experience significant retrograde flow and induce adverse physiologic responses. Catastrophic LVAD failure was investigated in computer simulation with pulsatile, axial, and centrifugal LVAD, mock flow loop with pulsatile (PVAD) and centrifugal (ROTAFLOW), and healthy and chronic ischemic heart failure bovine models with pulsatile (PVAD), axial (HeartMate II), and centrifugal (HVAD) pumps. Simulated conditions were LVAD "off" with outflow graft clamped (baseline), LVAD "off" with outflow graft unclamped (LVAD failure), and LVAD "on" (5 L/min).

View Article and Find Full Text PDF

High throughput heterogeneous immunoassays that screen antigen-specific antibody secreting cells are essential to accelerate monoclonal antibody discovery for therapeutic applications. Here, we introduce a heterogeneous single cell immunoassay based on alginate microparticles as permeable cell culture chambers. Using a microfluidic device, we encapsulated single antibody secreting cells in 35-40 μm diameter alginate microbeads.

View Article and Find Full Text PDF

We investigated the power consumption of a HeartMate III rotary blood pump based on in vitro experiments performed in a cardiovascular simulator. To create artificial-pulse mode, we modulated the pump speed by decreasing the mean speed by 2000 rpm for 200 ms and then increasing speed by 4000 rpm (mean speeds plus 2000 rpm) for another 200 ms, creating a square waveform shape. The HeartMate III was connected to a cardiovascular simulator consisting of a hydraulic pump system to simulate left ventricle pumping action, arterial and venous compliance chambers, and an adjustable valve for peripheral resistance to facilitate the desired aortic pressure.

View Article and Find Full Text PDF

Over the past few decades, advances in ventricular assist device (VAD) technology have provided a promising therapeutic strategy to treat heart failure patients. Despite the improved performance and encouraging clinical outcomes of the new generation of VADs based on rotary blood pumps (RBPs), their physiologic and hematologic effects are controversial. Currently, clinically available RBPs run at constant speed, which results in limited control over cardiac workload and introduces blood flow with reduced pulsatility into the circulation.

View Article and Find Full Text PDF

Objectives: Rotary blood pumps (RBPs) running at a constant speed are routinely used for the mechanical support of the heart in various clinical applications, from short-term use in heart-lung machines to long-term support of a failing heart. Their operating range is delineated by suction and regurgitation events, leaving limited control on the cardiac workload. This study investigates whether different ratios of systolic/diastolic support are advantageous over a constant-speed operation.

View Article and Find Full Text PDF

Objective: Mechanical support of a failing heart is typically performed with rotary blood pumps running at constant speed, which results in a limited control on cardiac workload and nonpulsatile hemodynamics. A potential solution to overcome these limitations is to modulate the pump speed to create pulses. This study aims at developing a pulsatile control algorithm for rotary pumps, while investigating its effect on left ventricle unloading and the hemodynamics.

View Article and Find Full Text PDF

In this study, the effect of time derivatives of flow rate and rotational speed was investigated on the mathematical modeling of a rotary blood pump (RBP). The basic model estimates the pressure head of the pump as a dependent variable using measured flow and speed as predictive variables. Performance of the model was evaluated by adding time derivative terms for flow and speed.

View Article and Find Full Text PDF