Publications by authors named "Todd Zelesky"

Stress testing (also known as forced degradation) of pharmaceutical drug substances and products is a critical part of the drug development process, providing insight into the degradation pathways of drug substances and drug products. This information is used to support the development of stability-indicating methods (SIMs) capable of detecting pharmaceutically relevant degradation products that might potentially be observed during manufacturing, long-term storage, distribution, and use. Assessing mass balance of stressed samples is a key aspect of developing SIMs and is a regulatory expectation.

View Article and Find Full Text PDF

Forced degradation (i.e., stress testing) of small molecule drug substances and products is a critical part of the drug development process, providing insight into the intrinsic stability of a drug that is foundational to the development and validation of stability-indicating analytical methods.

View Article and Find Full Text PDF

Gauging the chemical stability of active pharmaceutical ingredients (APIs) is critical at various stages of pharmaceutical development to identify potential risks from drug degradation and ensure the quality and safety of the drug product. Stress testing has been the major experimental method to study API stability, but this analytical approach is time-consuming, resource-intensive, and limited by API availability, especially during the early stages of drug development. Novel computational chemistry methods may assist in screening for API chemical stability prior to synthesis and augment contemporary API stress testing studies, with the potential to significantly accelerate drug development and reduce costs.

View Article and Find Full Text PDF

Stress testing of active pharmaceutical ingredients (API) is an important tool used to gauge chemical stability and identify potential degradation products. While different flavors of API stress testing systems have been used in experimental investigations for decades, the detailed kinetics of such systems as well as the chemical composition of prominent reactive species, specifically reactive oxygen species, are unknown. As a first step toward understanding and modeling API oxidation in stress testing, we investigated a typical radical "soup" solution an API is subject to during stress testing.

View Article and Find Full Text PDF

Stress testing (also known as forced degradation) of pharmaceutical products has long been recognized as a critical part of the drug development process, providing foundational information related to intrinsic stability characteristics and to the development of stability-indicating analytical methods. A benchmarking study was undertaken by nine pharmaceutical companies and the Brazilian Health Regulatory Agency (Agência Nacional de Vigilância Sanitária, or ANVISA) with a goal of understanding the utility of various stress testing conditions for producing pharmaceutically-relevant chemical degradation of drugs. Special consideration was given to determining whether solution phase stress testing of solid drug products produced degradation products that were both unique when compared to other stress conditions and relevant to the formal drug product stability data.

View Article and Find Full Text PDF

Accelerated stability studies of pharmaceutical products are commonly conducted at various combinations of temperature and relative humidity (RH). The RH of the sample environment can be controlled to set points using humidity-controlled stability chambers or via storage of the sample in a closed container in the presence of a saturated aqueous salt solution. Herein we report an unexpected N-nitrosation reaction that occurs upon storage of carvedilol- or propranolol-excipient blends in a stability chamber in the presence of saturated sodium nitrite (NaNO) solution to control relative humidity (∼60% RH).

View Article and Find Full Text PDF

Stability studies of pharmaceutical drug products and pharmaceutical active substances are important to research and development in order to fully understand and maintain product quality and safety throughout its shelf-life. Oxidative forced degradation studies are among the different types of stability studies performed by the pharmaceutical industry in order to understand the intrinsic stability of drug molecules. We have been comparing the use of electrochemistry as an alternative oxidative forced degradation method to traditional forced degradation and accelerated stability studies.

View Article and Find Full Text PDF

Formaldehyde and formic acid are reactive impurities found in commonly used excipients and can be responsible for limiting drug product shelf-life. Described here is the use of activated carbon in drug product packaging to attenuate formaldehyde-induced and formic acid-induced drug degradation in tablets and cross-linking in hard gelatin capsules. Several pharmaceutical products with known or potential vulnerabilities to formaldehyde-induced or formic acid-induced degradation or gelatin cross-linking were subjected to accelerated stability challenges in the presence and absence of activated carbon.

View Article and Find Full Text PDF

We report artifactual degradation of pharmaceutical compounds containing primary and secondary amines during peroxy radical-mediated oxidative stress carried out using azoalkane initiators. Two degradation products were detected when model drug compounds dissolved in methanol/water were heated to 40°C with radical initiators such as 2,2'-azobis(2-methylpropionitrile) (AIBN). The primary artifact was identified as an α-aminonitrile generated from the reaction of the amine group of the model drug with formaldehyde and hydrogen cyanide, generated as byproducts of the stress reaction.

View Article and Find Full Text PDF

The aim of this study was to evaluate the use of electrochemistry to generate oxidative degradation products of a model pharmaceutical compound. The compound was oxidized at different potentials using an electrochemical flow-cell fitted with a glassy carbon working electrode, a Pd/H2 reference electrode and a titanium auxiliary electrode. The oxidative products formed were identified and structurally characterized by LC-ESI-MS/MS using a high resolution Q-TOF mass spectrometer.

View Article and Find Full Text PDF

The International Conference on Harmonization (ICH) M7 guidance for the assessment and control of DNA reactive impurities in pharmaceutical products includes the use of in silico prediction systems as part of the hazard identification and risk assessment strategy. This is the first internationally agreed guidance document to include the use of these types of approaches. The guideline requires the use of two complementary approaches, an expert rule-based method and a statistical algorithm.

View Article and Find Full Text PDF

A newly commercialized high-resolution ultrasonic spectrometer was evaluated for simultaneously measuring concentrations of a model excipient (hypromellose acetate succinate polymer, HPMCAS, CAS No. 71138-97-1) and a model drug (Fenofibrate, CAS No. 49562-28-9) in acetone solution.

View Article and Find Full Text PDF

An alternative liquid chromatographic (LC) method was developed and validated for the simultaneous determination of methoxyl and 2-hydroxypropoxyl substituents in hypromellose and hypromellose acetate succinate. The method uses the hydriodic acid cleavage reaction, catalyzed by adipic acid, of the substituted methoxyl and 2-hydroxypropoxyl groups, which are quantitatively converted to iodomethane and 2-iodopropane. The iodomethane and 2-iodopropane are extracted into xylene, the extract is diluted with methanol, and the analytes are separated and assayed by gradient elution using a reversed-phase C18 column.

View Article and Find Full Text PDF

A reversed-phase liquid chromatographic method was developed and validated for the determination of the content of free acetic acid, free succinic acid, acetyl substituents, and succinoyl substituents in hydroxypropyl methylcellulose acetate succinate (HPMCAS; Chemical Abstracts Service Registry No. 71138-97-1) polymer. This single new method gave accurate and precise measurement of both acetyl and succinoyl substituents, which had previously required 3 Japanese Pharmaceutical Excipients (JPE) methods to accomplish.

View Article and Find Full Text PDF