Publications by authors named "Tinteri C"

The aim of this study was to evaluate the correlation between the microbial air contamination values obtained by active sampling (colony-forming units per cubic metre, CFU/m3) and by passive sampling (Index of microbial air contamination, IMA) and to calculate the corresponding equations. Air sampling was performed in ten dental clinics (DC), before (T0), during (T1) and after (T2) the clinical activity, for five consecutive days, once a month for a period of three months, for a total of 450 air samplings. The correlation was evaluated using the Spearman test, and a p value below 0.

View Article and Find Full Text PDF

Objective: The values of microbial growth in the air exiting from the heating, ventilation and air conditioning (HVAC) ducts treated with silver/zeolite have been shown to be lower than those in the air coming out the traditional metal ones. This study aims to verify how long this antimicrobial activity lasts.

Methods: All the tests were performed according to US ASTM E2180-01 and ISO-JIZ 22196 standards.

View Article and Find Full Text PDF

A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity.

View Article and Find Full Text PDF

The dental practice is associated with a high risk of infections, both for patients and healthcare operators, and the environment may play an important role in the transmission of infectious diseases. A microbiological environmental investigation was carried out in six dental clinics as a pilot study for a larger multicentre study that will be performed by the Italian SItI (Society of Hygiene, Preventive Medicine and Public Health) working group "Hygiene in Dentistry". Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days of the week, before and during treatments.

View Article and Find Full Text PDF

Introduction: Air pollution in confined environments is a serious health problem, in that most people spend long periods indoors (in homes, offices, classrooms etc.). Some people (children, the elderly, heart disease patients, asthmatic or allergic subjects) are at greater risk because of their conditions of frailty.

View Article and Find Full Text PDF

The air in hospital wards with patients at high risk (Surgeries, Intensive Care Units and Bone Marrow Transplant Centers) has been surveyed less than the one in Operating Rooms. Therefore in this study we considered useful to verify the microbic contamination of the air of those wards evaluating the consistency of ventilation systems in relation also to the presence and location of HEPA absolute filters. Seven departments of Genoese San Martino Hospital at high risk of infection were taken into account.

View Article and Find Full Text PDF

We evaluated Legionella pneumophila contamination of water and surrounding air in a burn care department equipped with bathtubs. In water, the bacterium always aerosolized, but in surrounding air, it diluted itself to such a point that it became undetectable at 1 m or more from the source of emission, which indicated that patients were at low risk of inhaling a dangerous quantity of the microbe.

View Article and Find Full Text PDF