Background: Accurate determination of the apical terminus plays a significant role in the success of root canal therapy, but accuracy may be affected by the presence of accessory canals.
Objective: To evaluate the accuracy of a ratio-based electronic apex locator for roots with simulated lateral canals.
Methods: Forty-two single-rooted human teeth were randomly divided into 2 groups.
The aim of this study was to investigate whether the use of operating microscope in combination with ultrasonics increased the rate of second mesiobuccal (MB2) canal detection in permanent maxillary first molar teeth. A hundred extracted human maxillary first molars were assessed. After location of the main canals, the MB2 canal was sought in all teeth first without microscopy, then with the aid of the operating microscope and finally with the combined use of the operating microscope and ultrasonics.
View Article and Find Full Text PDFAim: The focus of this study was to examine the staining potential of calcium hydroxide (Ca(OH)2) on tooth structure following the removal of AH26 root canal sealer.
Methods And Materials: Fifty maxillary anterior teeth were prepared and obturated with AH26 and gutta percha. The sealers were then removed 24 hours later and the teeth were randomly divided into two groups.
The aim of this study was to evaluate in vitro the effectiveness of TCM Endo V and Tri Auto ZX handpieces in detecting simulated horizontal and vertical root fractures. Forty extracted maxillary incisor teeth were randomly divided into 2 groups as simulated incomplete horizontal and vertical root fractures. Auto reverse and electronic apex locator functions of the 2 handpieces were used in both groups.
View Article and Find Full Text PDFWe aimed to evaluate the accuracy of 2 apex locator integrated endodontic motors during retreatment of root-end resected teeth by using 40 extracted incisor teeth. The apical 3 mm of the roots were resected, and the root lengths were recorded as resected length of the roots. Forty roots were randomly divided into 2 groups of 20 to evaluate the 2 handpieces, Tri Auto ZX and TCM Endo V.
View Article and Find Full Text PDFThe objective of this study was to assess the accuracy of two frequency apex locators, Root ZX (Morita, Kyoto, Japan) and Endex (Osada, Tokyo, Japan) in primary teeth with and without root resorption in vitro. For this study, 90 sound extracted primary teeth (60 molars and 30 incisors; 93 roots with visible resorption and 51 roots without) were selected. A total of 144 root canals were included.
View Article and Find Full Text PDFOral Surg Oral Med Oral Pathol Oral Radiol Endod
March 2007
Objective: The aim of this study was to evaluate the accuracy of the apex-locating function of the TCM Endo V and to compare the results to these of the Root ZX.
Study Design: Forty-seven extracted maxillary incisor teeth with mature apices and patent single root canals were used for the study. After the root surfaces were cleaned and access cavities were prepared, the true working lengths (TL) were determined with a #10 stainless steel file.
J Contemp Dent Pract
February 2006
Obtaining the cleanest canal possible before obturation is one of the goals of endodontic treatment. The purpose of this study was to compare the smear layer removal capability of ethylenediamine tetra-acetic acid (EDTA) application with passive ultrasonic and cotton wrapped on reamer activation. Twelve extracted human teeth with single root canals were used for the study.
View Article and Find Full Text PDFOne of the most important goals of the restoration of endodontically treated teeth with a composite resin post system is to achieve good adaptation of the composite material to dentin walls to prevent microleakage apically and coronally. In post core systems, to avoid microleakage between the dentin wall and resin material, laser irradiation may seem to be an alternative therapy for increasing adaptation quality. The aim of this study was to investigate the adaptation of a packable composite resin to lased root canal dentin when it was used as post material.
View Article and Find Full Text PDFThe aim of this study was to compare the amount of apical extrusion during manual instrumentation and engine-driven rotary instrumentation in teeth with disrupted apical constriction. Fifty-two teeth were divided into two groups comprising 26 teeth each. Teeth in each group were further divided into two sub-groups, the apices of which were enlarged approximately to a diameter of 0.
View Article and Find Full Text PDFThis study evaluates the amount of remaining tooth structure and possibility of producing lateral perforation following the use of different diameters of parallel-sided Parapost drills in groups of different canal curvatures (0 degrees-15 degrees, 16 degrees-25 degrees, 26 degrees <) in distal canals of first and second mandibular molar teeth. After enlargement of root canals using the crown-down pressureless technique, Parapost drills #1, #2, and #3 were used in the different canal groups for the preparation of a post space. Standardized digital radiographs were taken before the post space preparation and after each Parapost drill application.
View Article and Find Full Text PDFJ Contemp Dent Pract
February 2004
Correct use of instruments and irrigating solutions are major factors during chemo-mechanical preparation of root canals. Ultrasonically activated files and solutions are used for debridement of canals. In this study 42 single rooted anterior human teeth were used.
View Article and Find Full Text PDFThe purpose of this in vitro study was to evaluate the microhardness of packable composite compacted with hand or ultrasonic pluggers in post spaces. A total of 168 extracted human anterior teeth were prepared with Gates Glidden and ParaPost drills after obturation. A primer and a dentin-bonding agent were applied to the etched surface.
View Article and Find Full Text PDFAim: To describe and evaluate a newly developed model for demonstrating and teaching the use of electronic apex locators.
Summary: A phantom model, master jaw model and extracted human teeth were used to construct the demonstration model with alginate impression material as the periapical conductive medium. The model was validated in a series of length determinations with apical foramina enlarged to 0.
The main objective of this in vitro study was to evaluate the effects of the operator's experience level and pre-flaring on the accuracy of the results of three different brands of a new generation of root canal measuring devices, as well as the comparison among them. Extracted human teeth were prepared and then actual length and electronic length measurements were made by three different operators according to a double-blind technique. Three different operators performed electronic measurements on each specimen separately with three different electronic root canal measuring devices using in vitro models.
View Article and Find Full Text PDFIn endodontics, a laser can be used as a heat source and gutta-percha can be softened by a laser and used in the root canals. The System-B endodontic heat source unit was designed for the obturation of the root canal system with a single continuous wave of thermoplasticized gutta-percha. The aim of this study was to compare the apical leakage of lateral condensation; Nd: YAG laser-softened gutta-percha and System-B techniques.
View Article and Find Full Text PDFThe aim of this in vitro study was to evaluate the apical and coronal microleakage of a packable composite material compacted by either hand or ultrasonic condensers when placed in post spaces. Forty-two extracted anterior teeth were used. After conventional obturation of the root canals, parallel post spaces 5 mm in depth and 2 mm in diameter were prepared using Gates Glidden and diamond burs.
View Article and Find Full Text PDFThe incidence of interappointment emergencies in symptomatic and asymptomatic teeth with necrotic pulps was evaluated, and severity of flare-ups was determined by a quantitative method using a flare-up index. There were no significant differences in the incidence of flare-ups attributable to gender, age, diameter of lesion, taking analgesics, placebos, or no medication, or preoperative symptomatic or asymptomatic tooth diagnoses (p > 0.05).
View Article and Find Full Text PDFThis study aimed to evaluate Root ZX accuracy with different NaOCl concentrations and to observe effects of the alginate model when NaOCl was used in the canal during electronic measurements. Fifty extracted single-rooted, single-canal human teeth were used in five experimental groups. NaOCl concentrations of 5.
View Article and Find Full Text PDFActa Gastroenterol Belg
August 2001
Helicobacter pylori is regarded as an important pathogen playing a key role in the pathogenesis of peptic ulcer. Different studies about the mode of transmission of the microorganism report conflicting results about dental plaque as the source of H. pylori infection.
View Article and Find Full Text PDFA temporary filling should seal the endodontic access cavity to avoid reinfection of the root canal system during endodontic treatment. The aim of this study was to evaluate the marginal seal of four temporary filling materials in endodontic access cavities in vitro, using the dye penetration method. Endodontic access cavity preparations were in 50 incisor and 50 molar noncarious nonrestored crowns of extracted human teeth.
View Article and Find Full Text PDF