On-treatment EPID images are contaminated with patient-generated scattered photons. If this component can be accurately estimated, its effect can be removed, and therefore a corresponding in vivo patient dose estimate will be more accurate. Our group previously developed a "tri-hybrid" (TH) algorithm to provide fast but accurate estimates of patient-generated photon scatter.

View Article and Find Full Text PDF

Purpose: There is an increased interest in using non-coplanar beams for radiotherapy, including SBRT and SRS. This approach can significantly reduce doses to organs-at-risk, however, it requires stringent quality assurance, especially when a dynamic treatment couch is used. In this work, new functionality that allows using non-coplanar beam arrangements in addition to conventional coplanar beams was added and validated to the previously developed in vivo dose verification system.

View Article and Find Full Text PDF

The use of sophisticated techniques such as gating and tracking treatments requires additional quality assurance to mitigate increased patient risks. To address this need, we have developed and validated an in vivo method of dose delivery verification for real-time aperture tracking techniques, using an electronic portal imaging device (EPID)-based, on-treatment patient dose reconstruction and a dynamic anthropomorphic phantom. Using 4DCT scan of the phantom, ten individual treatment plans were created, 1 for each of the 10 separate phases of the respiratory cycle.

View Article and Find Full Text PDF

In vivo dosimetry methods can verify the prescription dose is delivered to the patient during treatment. Unfortunately, in exit dosimetry, the megavoltage image is contaminated with patient-generated scattered photons. However, estimation and removal of the effect of this fluence improves accuracy of in vivo dosimetry methods.

View Article and Find Full Text PDF

Scattered radiation unavoidably generated in the patient will negatively impact both kilovoltage (KV) and megavoltage (MV) imaging applications. Recently, 'hybrid' methods (i.e.

View Article and Find Full Text PDF

Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically.

Methods And Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy-volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment.

View Article and Find Full Text PDF

Purpose: The aim of this study is to investigate the performance and limitations of a real-time transit electronic portal imaging device (EPID) dosimetry system for error detection during dynamic intensity modulated radiation therapy (IMRT) treatment delivery. Sites studied are prostate, head and neck (HN), and rectal cancer treatments.

Methods: The system compares measured cumulative transit EPID image frames with predicted cumulative image frames in real-time during treatment using a χ comparison with 4 %, 4 mm criteria.

View Article and Find Full Text PDF

Purpose: Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based technique to compute full three-dimensional patient dose reconstructed from on-treatment EPID portal images (i.

View Article and Find Full Text PDF

Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption.

View Article and Find Full Text PDF