Publications by authors named "Timothy Shinn"

Background: The feasibility and outcomes of concomitant atrioventricular node ablation (AVNA) and leadless pacemaker implant are not well studied. We report outcomes in patients undergoing Micra implant with concomitant AVNA.

Methods: Patients undergoing AVNA at the time of Micra implant from the Micra Transcatheter Pacing (IDE) Study, Continued Access (CA) study, and Post-Approval Registry (PAR) were included in the analysis and compared to Micra patients without AVNA.

View Article and Find Full Text PDF

Background: Right ventricular pacing restores an adequate heart rate in patients with atrioventricular block, but high percentages of right ventricular apical pacing may promote left ventricular systolic dysfunction. We evaluated whether biventricular pacing might reduce mortality, morbidity, and adverse left ventricular remodeling in such patients.

Methods: We enrolled patients who had indications for pacing with atrioventricular block; New York Heart Association (NYHA) class I, II, or III heart failure; and a left ventricular ejection fraction of 50% or less.

View Article and Find Full Text PDF

Background: Infection following cardiovascular implantable electronic device (CIED) replacement is a serious complication, and rates of infection have increased. Analysis of procedural and clinical data from device replacement procedures collected by the REPLACE Registry may provide insights into infection prevention strategies and outcomes.

Methods: We prospectively evaluated procedural complications in patients undergoing CIED replacement over 6 months from 72 U.

View Article and Find Full Text PDF

Background: We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device.

Methods And Results: The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). Best-subset regression analysis was performed to identify factors associated with echocardiographic response (defined as percent reduction in left ventricular end-diastolic volume 1 year after CRT-D implantation) and to create a response score.

View Article and Find Full Text PDF

Background: Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates.

Methods And Results: We prospectively assessed predefined procedure-related complication rates associated with elective pacemaker or implantable cardioverter-defibrillator generator replacements over 6 months of follow-up.

View Article and Find Full Text PDF

Objectives: This study hypothesized that microvolt T-wave alternans (MTWA) improves selection of patients for implantable cardioverter-defibrillator (ICD) prophylaxis, especially by identifying patients who are not likely to benefit.

Background: Many patients with left ventricular dysfunction are now eligible for prophylactic ICDs, but most eligible patients do not benefit; MTWA testing has been proposed to improve patient selection.

Methods: Our study was conducted at 11 clinical centers in the U.

View Article and Find Full Text PDF

Background: In 2003, the Centers for Medicaid and Medicare Services recommended QRS duration as a means to identify MADIT II-like patients suitable for implanted cardiac defibrillator (ICD) therapy. We compared the ability of microvolt T-wave alternans and QRS duration to identify groups at high and low risk of dying among heart failure patients who met MADIT II criteria for ICD prophylaxis.

Methods And Results: Patients with MADIT II characteristics and sinus rhythm had a microvolt T-wave alternans exercise test and a 12-lead ECG.

View Article and Find Full Text PDF

The purpose of this study was to develop a better understanding of the pacing and sensing characteristics of electrodes placed in the proximal cardiac veins. A detailed mapping of the coronary sinus (CS) and great cardiac vein (GCV) was done on 25 patients with normal sinus rhythm using a deflectable electrophysiological catheter. Intrinsic bipolar electrograms and atrial and ventricular pacing voltage thresholds were measured.

View Article and Find Full Text PDF