A flow-through chamber was developed for toxicity testing of mobile species that require microscopic observation to assess viability and development; no sub-sampling was required in this method. Organisms were held in 1.5 mL volumes in 30 mm plastic petri plates adapted with two side sections containing 35 microm screening to provide drainage.
View Article and Find Full Text PDFPreset larval Mercenaria mercenaria were exposed to nominal concentrations of 1 (control) to 495 microg Cu/L in artificial seawater and monitored for mortality, activity, development, and metamorphosis in sealed 30-mm plastic petri plates containing 1.5 ml of artificial seawater or toxicant solution. The plastic petri plates sorbed only about 2.
View Article and Find Full Text PDF