Retina
December 2024
Purpose: Propose new terminology and evaluate the effectiveness of Therapeutic Refractive Vitrectomy (TRV) for selective removal of vitreous floaters and opacities (VFO) utilizing Standardized Kinetic Anatomical Functional Testing of VFO (SK VFO Test) and new ultra widefield (UWF) OCT imaging techniques.
Methods: Retrospective analysis. Twenty eyes underwent TRV for symptomatic VFO.
Aims: To develop a generative adversarial network (GAN) capable of generating realistic high-resolution anterior segment optical coherence tomography (AS-OCT) images.
Methods: This study included 142 628 AS-OCT B-scans from the American University of Beirut Medical Center. The Style and WAvelet based GAN architecture was trained to generate realistic AS-OCT images and was evaluated through the Fréchet Inception Distance (FID) Score and a blinded assessment by three refractive surgeons who were asked to distinguish between real and generated images.
Purpose: To investigate the efficacy of incorporating Generative Adversarial Network (GAN) and synthetic images in enhancing the performance of a convolutional neural network (CNN) for automated estimation of Implantable Collamer Lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT).
Methods: This study was a retrospective evaluation using synthetic data and real patient images in a deep learning framework. Synthetic ICL AS-OCT scans were generated using GANs and a secondary image editing algorithm, creating approximately 100,000 synthetic images.
Purpose: To evaluate the outcome of sequential customized therapeutic keratectomy (SCTK) in reducing higher order aberrations (HOAs) and improving quality of vision in highly aberrated corneas consequent to previous radial keratotomy (RK).
Methods: A retrospective review of patients undergoing SCTK treatment from January 2012 to October 2020 was conducted in the Eye Center, Humanitas Clinical and Research Center (Rozzano, Italy). Indications for treatment in patients who had RK were significantly and/or progressively reduced corrected distance visual acuity (CDVA) combined with visual symptoms critically affecting quality of life.
Purpose Of Review: Posterior chamber phakic intraocular lenses (pIOLs) are increasing in popularity as a viable alternative to laser refractive surgery. The purpose of this review is to evaluate the recent updates to pIOLs and to assess the advancements and safety of the procedure.
Recent Findings: Accurate lens sizing is the key determinant to suitable vault prediction, advancements to sizing formulae including the use of very high frequency (VHF) digital ultrasound and the application of artificial intelligence and machine learning has led to improved vault prediction and safety.
Purpose: To assess repeatability and agreement of corneal epithelial thickness mapping in eyes with keratoconus using three optical coherence tomography (OCT) devices featuring different technologies: spectral-domain (SD) OCT combined with Placido disk corneal topography (MS-39), swept-source OCT (Anterion), and SD-OCT (Avanti).
Methods: Three consecutive measurements were acquired with the three devices in 60 eyes with keratoconus. The mean epithelial thickness was calculated in the central 2-mm zone and in 2- to 5-mm and 5- to 7-mm diameter rings.
Purpose: To evaluate and compare the incidence of transient light sensitivity syndrome (TLSS) after myopic laser in situ keratomileusis (LASIK), hyperopic LASIK, and myopic small incision lenticule extraction (SMILE).
Methods: A retrospective analysis was performed of consecutive LASIK and myopic SMILE cases, performed with the VisuMax femtosecond laser and MEL 80 or MEL 90 excimer laser (both Carl Zeiss Meditec AG) between January 2010 and February 2021 at London Vision Clinic, London, United Kingdom. A chart review was performed to find cases of clinically significant TLSS, identified as patients prescribed anti-inflammatory medications between 2 weeks and 6 months after surgery to manage photophobia.
Purpose: To describe a standardized three-stage flap replacement protocol and report the incidence of microfolds after femtosecond laser-assisted laser in situ keratomileusis (LASIK) surgery.
Methods: A retrospective analysis of 14,374 consecutive LASIK procedures with the VisuMax femtosecond laser (Carl Zeiss Meditec) by two surgeons was conducted. As per the standardized procedure, all eyes underwent the three-stage flap replacement protocol consisting of controlled standardized minimal irrigation and flap repositioning after ablation, followed by fluorescein-controlled slit-lamp adjustments and slit-lamp adjustments on day 1 (if required).
Ophthalmic Surg Lasers Imaging Retina
May 2023
Objective: To introduce VFO and SK VFO Test: new, more representative terminology for symptoms of vitreous floaters/opacities (VFO) and new standardized kinetic (SK) anatomical-functional assessment.
Materials And Methods: Eight eyes underwent before-after limited vitrectomy (LV): best-corrected visual acuity, low-luminance visual acuity, Minnesota Low Vision Reading Chart near visual acuity in logMAR, contrast sensitivity function (CV1000E), and straylight measurements (SM) (HDA/LDA/C-Quant). SK infrared confocal scanning laser ophthalmoscopy (SK IRcSLO) and swept-source widefield optical coherence tomography (SS-WF-OCT) identified VFO and posterior vitreous detachment (PVD).
Purpose: To report the first refractive and visual outcomes of small incision lenticule extraction (SMILE) using the VISUMAX 800 femtosecond laser (Carl Zeiss Meditec AG).
Methods: This was a retrospective analysis of consecutive eyes treated by SMILE using the VISUMAX 800 femtosecond laser at London Vision Clinic, EuroEyes Group, London, United Kingdom. Inclusion criteria were patients aged younger than 45 years, a corrected distance visual acuity (CDVA) of 20/20 or better, and the 3-month postoperative timepoint data being available for analysis.
Purpose: To develop and validate a deep learning neural network for automated measurement of implantable collamer lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT).
Design: Cross-sectional retrospective study.
Methods: A total of 2647 AS-OCT scans were used from 139 eyes of 82 subjects who underwent ICL surgery in 3 different centers.
Purpose: To evaluate the changes on epithelial thickness before and after topical treatment in primary Sjögren syndrome-associated dry eye disease (SS-DED).
Methods: This was a prospective study that included referred women with SS-DED and healthy age-matched controls. Corneal epithelial thickness was evaluated using high-definition anterior segment optical coherence tomography (Cirrus 5000 HD-OCT) in the baseline first consultation, and four weeks after treatment with preservative free 1mg/1mL sodium hyaluronate.
Purpose: To report the outcomes of PRESBYOND Laser Blended Vision LASIK (Carl Zeiss Meditec AG) in presbyopic commercial and military pilots requiring Class 1 aeromedical certification.
Methods: This was a retrospective study of 23 consecutive pilots who underwent PRESBYOND Laser Blended Vision LASIK. Postoperative visits were conducted at 1 day and 1, 3, and 12 months.
Purpose: To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection.
Design: Multicenter cross-sectional case-control retrospective study.
Methods: A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations.
Purpose: To investigate the safety and effectiveness of small incision lenticule extraction (SMILE) in patients who have hyperopia with or without astigmatism.
Methods: This was a prospective multicenter trial including 374 eyes of 199 patients treated by SMILE for hyperopia using the VisuMax femtosecond laser (Carl Zeiss Meditec AG). Inclusion criteria were sphere up to +6.
Saudi J Ophthalmol
July 2022
In this review, we discuss the applications of epithelial thickness mapping in corneal refractive surgery. The review describes that the epithelial thickness profile is nonuniform in the normal eye, being thinner superiorly than inferiorly and thinner temporally than nasally. It is postulated that this is due to the eyelid forces and blinking action on the superior cornea.
View Article and Find Full Text PDFPurpose: To evaluate the effect of eye rubbing on the epithelial thickness profile in tomographically normal corneas by AS-OCT and to compare right and left eyes in right-handed children.
Methods: Thirty right-handed boys (mean age 11.2 years) with ocular allergy and history of eye rubbing were evaluated using Scheimpflug (Pentacam HR, Oculus Wetzlar, Germany) and anterior segment optical coherence tomography.
Purpose: To evaluate the outcomes of small incision lenticule extraction (SMILE) for myopia in a large population of young adults.
Methods: In this retrospective case series, the patient population consisted of the first 4,138 consecutive SMILE treatments using the VisuMax femtosecond laser (Carl Zeiss Meditec) between 2012 and 2018 at the London Vision Clinic. Inclusion criteria were myopic spherical equivalent up to -9.
Purpose: To analyze the optical consequences of epithelial remodeling in irregular corneas and their impact on the choice of different surface ablation techniques.
Methods: Anterior corneal and stromal surface topographies and epithelial thickness maps were analyzed in 24 eyes with irregular corneal optics. On two of the eyes, four different surface ablation techniques were simulated: (1) conventional anterior topography-guided photorefractive keratectomy (PRK), (2) transepithelial phototherapeutic keratectomy (PTK), (3) transepithelial anterior topography-guided PRK, and (4) stromal topography-guided PRK.
Purpose: To report subjective and objective quality of vision (QoV) results for high myopic small incision lenticule extraction (SMILE) between -9.00 and -13.00 diopters (D).
View Article and Find Full Text PDFPurpose Of Review: As more devices become available that offer corneal epithelial thickness mapping, this is becoming more widely used for numerous applications in corneal refractive surgery.
Recent Findings: The epithelial thickness profile is nonuniform in the normal eye, being thinner superiorly than inferiorly and thinner temporally than nasally. Changes in the epithelial thickness profile are highly predictable, responding to compensate for changes in the stromal curvature gradient, using the eyelid as an outer template.
Purpose: To assess the repeatability of corneal epithelial thickness mapping in virgin, post-laser refractive surgery (PLRS), and keratoconic eyes using a novel swept-source optical coherence tomographer (SS-OCT), and to determine the agreement of the measurements with a validated spectral-domain (SD) OCT.
Methods: Analysis of 90 virgin, 46 PLRS, and 122 keratoconic eyes was performed. Three consecutive measurements of each eye were acquired with the Anterion SS-OCT and Avanti SD-OCT devices, and averages of the epithelial thickness mapping were calculated in the central 2-mm zone and in the 2- to 5-mm and 5- to 7-mm diameter rings.
Purpose: To report the outcomes of small incision lenticule extraction (SMILE) for high myopia between -9.00 and -14.00 diopters (D).
View Article and Find Full Text PDF