Ultrasound visualization of vascular closure devices during endovascular access closure leads to a significant decrease in overall and major post interventional access site complications. This non-invasive and often readily available imaging technique could therefore lead to an important decrease in morbidity and subsequent overall health care costs when added to the standard intervention protocol. With the increasing use of endovascular techniques to treat peripheral artery disease, the addition of ultrasound-techniques in closure of endovascular access sites could potentially have a large clinical impact, both on patient outcomes as well as financial outcomes.

View Article and Find Full Text PDF

Objective: The arteriovenous fistula (AVF) is the first choice for gaining vascular access for hemodialysis. However, 20% to 50% of AVFs fail within 4 months after creation. Although demographic risk factors have been described, there is little evidence on the intraoperative predictors of AVF maturation failure.

View Article and Find Full Text PDF

Purpose: To determine patient and hip fracture characteristics, early postoperative complication rate, and need for institutionalization at the time of discharge from the hospital in patients treated for a second contralateral hip fracture.

Methods: During a 6-year period (2003-2009), 71 patients (60 women and 11 men; age range, 54-94 years) underwent first hip fracture surgery and subsequent contralateral hip fracture surgery at our hospital. Variables, including age, gender, American Society of Anesthesiologists classification (ASA), AO fracture classification, time between both hip fractures, rate and severity of early postoperative complications, and destination of discharge were obtained from the electronic medical records.

View Article and Find Full Text PDF

Purpose: To investigate if an elastomer [polydimethylsiloxane (PDMS)] can be used to effectively treat endoleaks after endovascular aneurysm repair.

Methods: A latex aneurysm (36-mm inner diameter sac, 15-mm inner diameter neck) was attached to an in vitro circulation model. The aneurysm was excluded from the circulation by placing an unstented polyester graft.

View Article and Find Full Text PDF

Endovascular techniques, including branched devices to preserve the internal iliac artery are evolving rapidly, but in cases in which the diameter of the proximal sealing zone is larger than that of the distal sealing zone, a reversed tapered device is needed. We describe the off label use of the Gore Excluder contralateral leg endoprosthesis in an upside down configuration to accommodate this diameter mismatch. The preinsertion technical steps of stent graft preparation, which do not require extracorporeal predeployment, are described in detail.

View Article and Find Full Text PDF

The aim of this study was the evaluation of contralateral hip fractures after a previous hip fracture. For this retrospective analysis patients were selected from the database of the LUMC, a teaching hospital in the south-west of the Netherlands. We analyzed all patients with a second fracture of a hip between 1992 and 2007.

View Article and Find Full Text PDF

Purpose: One of the major concerns in the long-term success of endovascular aneurysm repair (EVAR) is stent graft migration, which can cause type I endoleak and even aneurysm rupture. Fixation depends on the mechanical forces between the graft and both the aortic neck and the blood flow. Therefore, there are anatomical restrictions for EVAR, such as short and angulated necks.

View Article and Find Full Text PDF

Purpose: Aortic Customize is a new concept for endovascular aortic aneurysm repair in which a non polymerized elastomer is injected to fill the aneurysm sac around a balloon catheter. The aim of this in vitro study was to investigate the extent of aneurysm wall stress reduction by the presence of a noncompliant elastomer cuff.

Methods: A thin-walled latex aneurysm (inner radius sac 18 mm, inner radius neck 8 mm), equipped with 12 tantalum markers, was attached to an in vitro circulation model.

View Article and Find Full Text PDF

The use of Souter-Strathclyde total elbow prostheses is a well-studied replacement therapy for reconstruction of the elbow, but loosening of the humeral component is still of concern at long-term follow-up. In this study we looked at the effect of humeral component size and bone mineral density with respect to the bone size, torsional stiffness and torque to failure in cadaveric bones. Fourteen cadaveric humeri were available for testing purposes and four different humeral component size categories were used.

View Article and Find Full Text PDF
Article Synopsis
  • This study explores how pre-transplant hamster blood transfusion (HBT) combined with cyclosporin A (CSA) impacts the survival of hamster hearts transplanted into Lewis rats.
  • In athymic nude rats, HBT leads to long-term heart survival, while in immunocompetent Lewis rats, HBT alone causes hyperacute rejection (HAR).
  • However, when combined with high doses of CSA, both treatments result in significantly improved long-term survival rates for the transplants, highlighting the crucial role T cells play in the rejection process post-transfusion.
View Article and Find Full Text PDF

The objective of this study was to determine the role of a mortality registration in the quality control of patients who died after peripheral bypass surgery. We developed a mortality registration to classify causes of death, to evaluate shortcomings in treatment, and to determine the extent of agreement between pre- and postmortem findings. In a 10-year period, 28 of the 1,022 patients (2.

View Article and Find Full Text PDF