Publications by authors named "Tim Woods"

Venom-induced consumption coagulopathy (VICC) is a common complication of snakebite that is associated with hypofibrinogenemia, bleeding, disability, and death. In remote tropical settings, where most snakebites occur, the 20-minute whole blood clotting test is used to diagnose VICC. Point-of-care (POC) coagulation devices could provide an accessible means of detecting VICC that is better standardized, quantifiable, and more accurate.

View Article and Find Full Text PDF

The COVID-19 pandemic and associated public health and social distancing mandates caused unprecedented shifts and disruptions for local and regional food systems (LRFS). The pandemic also brought new and heightened attention to the structure and resiliency of US food systems, and LRFS appeared to be positioned to significantly increase the scope and scale of their market reach as a result. Researchers from three universities collaborated with staff from the U.

View Article and Find Full Text PDF

Introduction: Inhibitor formation is the greatest challenge facing persons with haemophilia treated with factor concentrates. The gold standard testing methodologies are the Nijmegen-Bethesda assay (NBA) for FVIII and Bethesda assay (BA) for FIX inhibitors, which are affected by pre-analytical and inter-laboratory variability.

Aims: To evaluate inhibitor testing methodology and assess correlation between self-reported and actual methodology.

View Article and Find Full Text PDF

Introduction: Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing.

Materials And Methods: Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration.

View Article and Find Full Text PDF

Introduction: Emicizumab (Hemlibra: Roche Switzerland) is a, humanized, bi-specific monoclonal modified immunoglobulin G4 (IgG4) which binds human FX, FIX and activated FIX (FIXa) to mimic activated FVIII activity.

Aim: Evaluate the effects of emicizumab on the APTT, surrogate FVIII activity and FVIII inhibitor results.

Methods: Two samples were provided, one obtained from an emicizumab treated severe haemophilia A patient with FVIII inhibitors and one constructed by in vitro addition of emicizumab using plasma from a severe haemophilia A patient without FVIII inhibitors.

View Article and Find Full Text PDF

Objectives: To examine the association of wet bulb globe temperature (WBGT) with the occurrence of heat-related incidents and changes in behavioural and matchplay characteristics in men's Grand Slam tennis.

Design: On-court calls for trainers, doctors, cooling devices and water, post-match medical consults and matchplay characteristic data were collected from 360 Australian Open matches (first 4 rounds 2014-2016).

Methods: Data were referenced against estimated WBGT and categorised into standard zones.

View Article and Find Full Text PDF

Transmembrane AMPA receptor regulatory proteins (TARPs) are a family of scaffolding proteins that regulate AMPA receptor trafficking and function. TARP γ-8 is one member of this family and is highly expressed within the hippocampus relative to the cerebellum. A selective TARP γ-8-dependent AMPA receptor antagonist (TDAA) is an innovative approach to modulate AMPA receptors in specific brain regions to potentially increase the therapeutic index relative to known non-TARP-dependent AMPA antagonists.

View Article and Find Full Text PDF

Global hemostasis devices are currently being employed in operating rooms to assess the bleeding risk and outcomes for patients undergoing surgery. Two devices currently available are the TEG (Thromboelastograph; Haemoscope Corp., Niles, IL) and the ROTEM (Rotation Thromboelastometer; Pentapharm GmbH, Munich, Germany).

View Article and Find Full Text PDF

We report the results of external quality assessment exercises in which 60 to 120 centers performed factor VIII (FVIII) inhibitor testing on a series of samples over a 13-year period. Samples from seven different subjects were distributed for analysis comprising the following: four different subjects with severe hemophilia A with antibodies following replacement therapy, one subject with acquired hemophilia A and antibodies to FVIII, one subject with normal FVIII and an easily detected lupus anticoagulant, and one subject with mild hemophilia A and a difficult-to-detect lupus anticoagulant but without antibodies to FVIII. In all of the surveys the results obtained in different centers analyzing the same sample varied to an extent that would influence patient management decisions.

View Article and Find Full Text PDF

Point-of-care (POC) testing in the field of hemostasis is rapidly expanding in many countries. This includes use of global tests of hemostasis in operating theaters and especially use of POC monitors for determination of the international normalized ratio (INR) for monitoring oral anticoagulant therapy. Issues related to internal quality control and external quality assessment for these devices are reviewed.

View Article and Find Full Text PDF

External quality assessment (EQA) or proficiency testing is widely considered to be necessary for International Normalised Ratio (INR) determinations performed in conventional laboratory settings. There is increasing use of near-patient-test (NPT) or point-of-care (POC) INR devices and it is not known whether EQA is also necessary for these monitors. We report here on six years experience of proficiency testing for POC monitors used by health care professionals.

View Article and Find Full Text PDF

In recognition of the importance of von Willebrand factor (vWF) testing in the diagnosis of von Willebrand disease (vWD), the United Kingdom National External Quality Assessment Scheme for Blood Coagulation regularly distributes samples for determination of vWF:antigen (vWF:Ag). Data from 10 separate surveys performed between 2001 and 2005 are reviewed. These include results from ~200 different centers, of which 55% are within the United Kingdom and the remainder are from other countries.

View Article and Find Full Text PDF