Due to variations in chemical composition and production processes, homonymous austenitic stainless steels can differ significantly regarding their initial microstructure, metastability, and thus, their fatigue behavior. Microstructural investigations and fatigue tests have been performed in order to evaluate this aspect. Three different batches and production forms of nominally one type of steel AISI 347 were investigated under monotonic tensile tests and cyclic loading under total strain and stress control in low and high cycle fatigue regimes, respectively.