Introduction: Visualization of scoliosis typically requires ionizing radiation (radiography and CT) to visualize bony anatomy. MRI is often additionally performed to screen for neural axis abnormalities. We propose a 14-minutes radiation-free scoliosis-specific MRI protocol, which combines MRI and MRI-based synthetic CT images to visualize soft and osseous structures in one examination.
View Article and Find Full Text PDFThe neuronal tricarboxylic acid and glutamate/glutamine (Glu/Gln) cycles play important roles in brain function. These processes can be measured in vivo using dynamic H-[C] MRS during administration of C-labeled glucose. Proton-observed carbon-edited (POCE) MRS enhances the signal-to-noise ratio (SNR) compared with direct C-MRS.
View Article and Find Full Text PDFThe generation of subject-specific finite element models of the spine is generally a time-consuming process based on computed tomography (CT) images, where scanning exposes subjects to harmful radiation. In this study, a method is presented for the automatic generation of spine finite element models using images from a single magnetic resonance (MR) sequence. The thoracic and lumbar spine of eight adult volunteers was imaged using a 3D multi-echo-gradient-echo sagittal MR sequence.
View Article and Find Full Text PDFChemical exchange saturation transfer (CEST) has been explored for differentiation between tumour and benign tissue in prostate cancer (PCa) patients. With ultrahigh field strengths such as 7-T, the increase of spectral resolution and sensitivity could allow for selective detection of amide proton transfer (APT) at 3.5 ppm and a group of compounds that resonate at 2 ppm (i.
View Article and Find Full Text PDFPurpose: To bring metabolic imaging based on multi-NMR toward practical use from the RF hardware perspective.
Methods: A highly integrated RF coil is designed for whole-brain MRI and MRS targeted to five nuclear species: H, F, P, Na, and C. Dipole antennas and closely loaded local receiver loops are combined in this setup.
Quantitative three-dimensional (3D) imaging of phosphorus ( P) metabolites is potentially a promising technique with which to assess the progression of liver disease and monitor therapy response. However, P magnetic resonance spectroscopy has a low sensitivity and commonly used P surface coils do not provide full coverage of the liver. This study aimed to overcome these limitations by using a P whole-body transmit coil in combination with a 16-channel P receive array at 7 T.
View Article and Find Full Text PDFSurgery for tongue cancer often results in a major loss in quality of life. While MRI may be used to minimise the volume of excised tissue, often the full tumour extent is missed. This tumour extent may be detected with metabolic imaging.
View Article and Find Full Text PDFThe goal of this study was to introduce and evaluate the performance of a lightweight, high-performance, single-axis (z-axis) gradient insert design primarily intended for high-resolution functional magnetic resonance imaging, and aimed at providing both ease of use and a boost in spatiotemporal resolution. The optimal winding positions of the coil were obtained using a genetic algorithm with a cost function that balanced gradient performance (minimum 0.30 mT/m/A) and field linearity (≥16 cm linear region).
View Article and Find Full Text PDFPurpose: This study evaluates the performance of 2 processing methods, that is, principal component analysis-based denoising and Wiener deconvolution, to enhance the quality of phosphorus 3D chemical shift imaging data.
Methods: Principal component analysis-based denoising increases the SNR while maintaining spectral information. Wiener deconvolution reduces the FWHM of the voxel point spread function, which is increased by Hamming filtering or Hamming-weighted acquisition.
Currently, it is difficult to predict effective therapy response to molecular therapies for the treatment of lung cancer based solely on anatomical images. P MR spectroscopic imaging could provide as a non-invasive method to monitor potential biomarkers for early therapy evaluation, a necessity to improve personalized care and reduce cost. However, surface coils limit the imaging volume in conventional P MRSI.
View Article and Find Full Text PDFPurpose: To demonstrate that proton resonance frequency shift MR thermometry (PRFS-MRT) acquisition with nonselective free induction decay (FID), combined with coil sensitivity profiles, allows spatially resolved B drift-corrected thermometry.
Methods: Phantom experiments were performed at 1.5T and 3T.
Phosphorus MRS offers a non-invasive tool for monitoring cell energy and phospholipid metabolism and can be of additional value in diagnosing cancer and monitoring cancer therapy. In this study, we determined the transverse relaxation times of a number of phosphorous metabolites in a group of breast cancer patients by adiabatic multi-echo spectroscopic imaging at 7 T. The transverse relaxation times of phosphoethanolamine, phosphocholine, inorganic phosphate (P ), glycerophosphocholine and glycerophosphatidylcholine were 184 ± 8 ms, 203 ± 17 ms, 87 ± 8 ms, 240 ± 56 ms and 20 ± 10 ms, respectively.
View Article and Find Full Text PDFPurpose: Robust fat suppression is essential in bilateral breast MRI at 7 Tesla. The lack of good fat suppression can result in errors when calculating the enhancement curve from dynamic contrast-enhanced acquisitions. In this work we propose discretized frequency shimming to improve the quality of fat suppression by exploiting the capabilities of a parallel transmit setup.
View Article and Find Full Text PDFPurpose: To compare methods for estimating B maps used in retrospective correction of high-resolution anatomical images at ultra-high field strength. The B maps were obtained using three methods: (1) 1D navigators and coil sensitivities, (2) field probe (FP) data and a low-order spherical harmonics model, and (3) FP data and a training-based model.
Methods: Data from nine subjects were acquired while they performed activities inducing B field fluctuations.
The aim of this study is to compare the current state of lesion identification, the BI-RADS classification and the contrast-enhancement behavior at 7T and 3T breast MRI in the same patient group. Twenty-seven patients with thirty suspicious lesions were selected for this prospective study and underwent both 7T and 3T MRI. All examinations were rated by two radiologists (R1 and R2) independently on image quality, lesion identification and BI-RADS classification.
View Article and Find Full Text PDFObjectives: To compare water selective excitation (WSE) and Dixon fat suppression in the context of high-resolution dynamic contrast enhanced MRI of the breast at 7T.
Methods: Ten healthy volunteers and one patient with a malignant breast lesion were scanned at 7T. The MRI protocol contained 3D T1-weighted gradient echo images obtained with both WSE fat suppression, multi echo Dixon fat suppression, and without fat suppression.
Objectives: To describe and to correlate tumor characteristics on multiparametric 7 tesla (T) breast magnetic resonance imaging (MRI) with prognostic characteristics from postoperative histopathology in patients with breast cancer.
Materials And Methods: Institutional review board approval and written informed consent of 15 women (46-70 years) with 17 malignant lesions were obtained. In this prospective study (March 2013 to March 2014), women were preoperatively scanned using dynamic contrast-enhanced MRI, diffusion-weighted imaging, and 31-phosphorus spectroscopy (¹³P-MRS).
Purpose: Fluctuations of the background magnetic field (B0 ) due to body and breathing motion can lead to significant artifacts in brain imaging at ultrahigh field. Corrections based on real-time sensing using external field probes show great potential. This study evaluates different aspects of field interpolation from these probes into the brain which is implicit in such methods.
View Article and Find Full Text PDFPurpose: High-resolution MRI combined with phospholipid detection may improve breast cancer grading. Currently, configurations are optimized for either high-resolution imaging or (31) P spectroscopy. To be able to perform both imaging as well as spectroscopy in a single session, we integrated a (1) H receiver array into a (1) H-(31) P transceiver at 7T.
View Article and Find Full Text PDFPurpose: To evaluate the 7 Tesla (T) MRI of the carotid arteries, as quantitatively compared with 3T.
Materials And Methods: The 7T MRI of the carotid arteries was performed in six healthy subjects and in two patients with carotid stenosis. The healthy group was scanned at 3T and at 7T, using current coil setups at both field strengths.