Due to the better survival of patients with tumorous diseases, it is increasingly important to predict the side effects of radiotherapy, for which the Radiation-Induced Lymphocyte Apoptosis (RILA) method is proving to be effective in multicentric studies. Prostate cancer is the leading cause of cancer-related deaths among men worldwide, which is usually treated with radiotherapy. We recruited 49 patients with localized prostate cancer and performed RILA measurements before radiotherapy.
View Article and Find Full Text PDFBackground And Purpose: Cone beam computed tomography (CBCT) is routinely used in radiotherapy to localize target volume. The aim of our study was to determine the biological effects of CBCT dose compared to subsequent therapeutic dose by using in vitro chromosome dosimetry.
Materials And Methods: Peripheral blood samples from five healthy volunteers were irradiated in two phantoms (water filled in-house made cylindrical, and Pure Image CTDI phantoms) with 6 MV FFF X-ray photons, the dose rate was 800 MU/min and the absorbed doses ranged from 0.
We present evaluation of junction of coplanar external beam photon fields and its portal dosimetric analysis for breast cancer with positive lymph nodes. In our work, we compared twelve patients affected by breast cancer with axillary and supraclavicular lymph nodes, using conformal external beam plans from a dosimetric point of view. 3-3 plans were prepared per patient.
View Article and Find Full Text PDFIn the Radiotherapy Centre of the National Institute of Oncology, Budapest, a 0.55 T MR scanner (MAGNETOM Free. Max) and a ring-like X-ray machine (ImagingRing) have been in operation since 2022.
View Article and Find Full Text PDFMost of the neck node metastases from cancer of unknown primary (CUP) are squamous cell carcinomas (SCCs). The majority of which are human papillomavirus (HPV)-related, frequently show cystic morphology referring to Waldeyer's ring origin. Here, we report four cases of neck node SCCs metastases from CUP.
View Article and Find Full Text PDFBackground: The aim of the study was to dosimetrically compare interstitial high-dose-rate (HDR) brachytherapy (BT) and modern external beam radiotherapy modalities, as volumetric modulated arc therapy (VMAT) and stereotactic radiotherapy with Cyberknife (CK) of tumours of the tongue and floor of the mouth in terms of dose to the critical organs.
Patients And Methods: In National Institute of Oncology, Budapest, between March 2013 and August 2022 twenty patients (11 male/9 female) with stage T1-3N0M0 tongue (n = 14) and floor of mouth (n = 6) tumours received postoperative radiotherapy because of close/positive surgical margin and/or lymphovascular and/or perineural invasion. High-dose-rate interstitial brachytherapy applying flexible plastic catheters with a total dose of 15 × 3 Gy was used for treatment.
Varian Halcyon (HA) linear accelerators (LINAC) require kilovoltage cone-beam computed tomography (CT) acquisition for all patients before all treatment fractions. The aim of this study is to compare dose indices of various available protocols with different calculation and measurement methods. CT dose index (CTDI) in mGy is a measure of the radiation dose output of a CT scanner.
View Article and Find Full Text PDFPurpose: To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients.
Material And Methods: Sixty patients with cervical cancer without vaginal involvement were selected for the study, who received intra-cavitary/interstitial BT. For each patient, two plans with and without active source dwell positions in R/O were created, using the same dose-volume constraints.
Background: Several randomised, phase 3 trials have investigated the value of different techniques of accelerated partial breast irradiation (APBI) for patients with early breast cancer after breast-conserving surgery compared with whole-breast irradiation. In a phase 3 randomised trial, we evaluated whether APBI using multicatheter brachytherapy is non-inferior compared with whole-breast irradiation. Here, we present the 10-year follow-up results.
View Article and Find Full Text PDFRadiotherapy has a significant role in the management of cervical cancer. Radiotherapy is indicated in two-thirds of all cervical cancer patients. Indications of radiotherapy are based on level I-II evidences in the vast majority of cases, although in some cases the use of radiotherapy is supported by the results of retrospective clinical trials.
View Article and Find Full Text PDFBackground: The purpose of this study was to investigate the dose coverage of sentinel lymph nodes (SLN), level I, II and III axillary volumes from tangent fields for breast cancer patients with positive SLN without axillary dissection.
Materials And Methods: In 30 patients with cN0 invasive breast cancer treated with breast conserving surgery and SLN biopsy, the SLN area was intraoperatively marked with a titanium clip. Retrospectively, the SLN area and axillary target volumes were contoured, and three plans [standard tangent fields (STgF), high tangent fields (HTgF), and STgF + axillary-supraclavicular field] were generated for each patient.
Background: The purpose of the study was to dosimetrically compare multicatheter interstitial brachytherapy (MIBT) and stereotactic radiotherapy with CyberKnife (CK) for accelerated partial breast irradiation with special focus on dose to organs at risk (OARs).
Materials And Methods: Treatment plans of thirty-one patients treated with MIBT were selected and additional CK plans were created on the same CT images. The OARs included ipsilateral non-target and contralateral breast, ipsilateral and contralateral lung, skin, ribs, and heart for left sided cases.
Brachytherapy (BT) and external beam radiotherapy (EBRT) apply different dose rates, overall treatment times, energies and fractionation. However, the overall impact of these variables on the biological dose of blood is neglected. As the size of the irradiated volume influences the biological effect as well, we studied chromosome aberrations (CAs) as biodosimetric parameters, and explored the relationship of isodose surface volumes (ISVs: V, V, V, V, V, V) and CAs of both irradiation modalities.
View Article and Find Full Text PDFBackground: In the case of dynamic radiotherapy plans, the fractionation schemes can have dosimetric effects. Our goal was to define the effect of the fraction dose on the plan quality and the beam delivery.
Materials And Methods: Treatment plans were created for 5 early-stage lung cancer patients with different dose schedules.
Brachytherapy (BT) has long been used for successful treatment of various tumour entities, including prostate, breast and gynaecological cancer. However, particularly due to advances in modern external beam techniques such as intensity-modulated radiotherapy (IMRT), volume modulated arc therapy (VMAT) and stereotactic body radiotherapy (SBRT), there are concerns about its future. Based on a comprehensive literature review, this article aims to summarize the role of BT in cancer treatment and highlight its particular dosimetric advantages.
View Article and Find Full Text PDFÖsszefoglaló. A szájüregi daganatok kuratív kezelésében az elsődlegesen választandó műtét mellett a sugárterápiának is jelentős szerepe van. A lokális tumormentesség biztosításához azonban dóziseszkaláció szükséges.
View Article and Find Full Text PDFDelineation of target and 'organ at risk' volumes is a critical part of modern radiation therapy planning, the next essential step after deciding the indication, patient discussion and image acquisition. Adoption of volume-based treatment planning for non-metastatic breast cancer has increased greatly along with the use of improved planning techniques, essential for modern therapy. However, identifying the volumes on a planning CT is no easy task.
View Article and Find Full Text PDFBackground: The aim of the study was to evaluate acute side effects after extremely hypofractionated intensity-modulated radiotherapy (IMRT) with stereotactic body radiation therapy (SBRT) for definitive treatment of prostate cancer patients.
Patients And Methods: Between February 2018 and August 2019, 205 low-, intermediate- and high-risk prostate cancer patients were treated with SBRT using "CyberKnife M6" linear accelerator. In low-risk patients 7.
Background: The objective of the study was to dosimetrically compare the intensity-modulated-arc-therapy (IMAT), Cyber-Knife therapy (CK), single fraction interstitial high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy (BT) in low-risk prostate cancer.
Materials And Methods: Treatment plans of ten patients treated with CK were selected and additional plans using IMAT, HDR and LDR BT were created on the same CT images. The prescribed dose was 2.
Purpose: This study was designed to assess dosimetric characteristics of 3D-printed personalized multi-channel cylinder applicator (MCCA).
Material And Methods: UnionTech RS Pro 600 (UnionTech, Inc., Shanghai, China) 3D printer was used for manufacturing MCCA.
Background: The aim of the study was to dosimetrically compare multicatheter interstitial brachytherapy (MIBT) and stereotactic radiotherapy with CyberKnife (CK) for accelerated partial breast irradiation (APBI) especially concerning the dose of organs at risk (OAR-s).
Patients And Methods: Treatment plans of thirty-two MIBT and CK patients were compared. The OAR-s included ipsilateral non-target and contralateral breast, ipsilateral and contralateral lung, skin, ribs, and heart for left-sided cases.