Introduction: One of the most helpful aspects of intracardiac echocardiography (ICE) implementation in electrophysiological studies (EPS) is the real-time visualisation of catheters and cardiac structures. In this prospective study, we investigated ICE-guided zero-fluoroscopy catheter navigation during radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) in patients with typical atrial flutter (AFL).
Methods And Results: Thirty consecutive patients (mean age 72.
Background: Chronic heart disease affects millions of people worldwide and the prevalence is increasing. By now, there is an extensive literature on outpatient care of people with chronic heart disease. We aimed to systematically identify and map models of outpatient care for people with chronic heart disease in terms of the interventions included and the outcomes measured and reported to determine areas in need of further research.
View Article and Find Full Text PDFBackground: Atrial fibrillation (AF) is associated with significant morbidity and is predicted by atrial high rate events. The early detection of AF is paramount to timely interventions to reduce the morbidity of AF. The DX ICD system combined with Home Monitoring® allows for continuous atrial rhythm monitoring without the need for a dedicated atrial lead.
View Article and Find Full Text PDFA promising treatment for congestive heart failure is the implementation of a left ventricular assist device (LVAD) that works as a mechanical pump. Modern LVADs work with adjustable constant rotor speed and provide therefore continuous blood flow; however, recently undertaken efforts try to mimic pulsatile blood flow by oscillating the pump speed. This work proposes an algorithmic framework to construct and evaluate optimal pump speed policies with respect to generic objectives.
View Article and Find Full Text PDFAims: Failure of right ventricular (RV) function worsens outcome in pulmonary hypertension (PH). The adaptation of RV contractility to afterload, the RV-pulmonary artery (PA) coupling, is defined by the ratio of RV end-systolic to PA elastances (Ees/Ea). Using pressure-volume loop (PV-L) technique we aimed to identify an Ees/Ea cut-off predictive for overall survival and to assess hemodynamic and morphologic conditions for adapted RV function in secondary PH due to heart failure with reduced ejection fraction (HFREF).
View Article and Find Full Text PDFAims: The aim of this study was to validate the tricuspid annular plane systolic excursion/systolic pulmonary artery (PA) pressure (TAPSE/PASP) ratio with the invasive pressure-volume (PV) loop-derived end-systolic right ventricular (RV) elastance/PA elastance (Ees/Ea) ratio in patients with heart failure with reduced ejection fraction (HFREF) and secondary pulmonary hypertension (PH).
Methods And Results: The relationship of TAPSE and TAPSE/PASP with RV-PV loop (single-beat)-derived contractility Ees, afterload Ea, and Ees/Ea was assessed in 110 patients with HFREF with and without secondary PH. The results were compared with other surrogate parameters such as the fractional area change/PASP ratio.
Background: A new zero-fluoroscopy technique for electrophysiology catheter navigation relying on intracardiac echocardiography (ICE) has been recently reported (Ice&ICE trial). We investigated potential differences in efficacy, safety or procedural performance between conventional fluoroscopy- and ICE-guided cryothermal ablation (CA) in symptomatic AVNRT patients.
Methods: Clinical and electrophysiological data of AVNRT patients included in the Ice&ICE trial (22 patients, 16 females; =zero-fluoroscopy group) were compared to those of consecutive AVNRT patients, who underwent fluoroscopy-guided CA (25 patients, 17 females; = fluoroscopy group) during the last 2 years in our institution.
Aims: The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD).
Methods And Results: The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs.
Background: Various lead designs have been developed to accommodate different coronary sinus anatomies. Our objectives were to compare electrical parameters of straight and spiral left ventricular leads, to evaluate capture thresholds and impedances using different pacing vectors, and to study evolution of thresholds over time.
Methods: The RALLY-X4 study enrolled patients implanted with a lead from the Acuity X4 family (straight, spiral short, or spiral long).
Background: Right ventricular (RV) dysfunction is recognized as a cardinal prognostic marker in systolic heart failure patients. Conflicting data exist on the interaction of RV function and left ventricular (LV) reverse remodeling after cardiac resynchronization therapy (CRT). This prospective monocentric trial was set up to assess the predictive value of baseline RV function and corresponding RV-pulmonary artery (PA) coupling on LV reverse remodeling after CRT.
View Article and Find Full Text PDFBackground: Implantable cardioverter/defibrillator (ICD) shocks can cause myocardial injury, contributing to the progression of the underlying heart disease. The aim was to evaluate whether internal electrical cardioversion (int-CV) via the ICD or conventional external CV (ext-CV) of persistent atrial fibrillation (AF) in heart failure (HF) patients induces myocardial injury and initiates inflammation.
Methods And Results: A total of 115 HF patients with an ejection fraction between 20% and 45% were prospectively enrolled.
Background: Interventional closure of the left atrial appendage (LAA) in patients with non-valvular atrial fibrillation, high thromboembolic and bleeding risk or bleeding history is an alternative therapeutic strategy to oral anticoagulation. It is not known if the exclusion of the LAA from the blood circulation affects the left atrial volume (LAV) and consequently its prognostic value or the circulatory performance of the heart in humans.
Methods: We aimed to prospectively assess potential changes in baseline LAV, left ventricular ejection fraction (LVEF), NT-proBNP-level and the covered distance in the 6-min walk-test 6 weeks and 6 months after LAA closure with the WATCHMAN™ device.
Introduction: Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest.
Methods And Results: We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization.
Background: Closure of the left atrial appendage (LAA) to prevent cardioembolic events is an alternative therapy to oral anticoagulation in patients with non-valvular atrial fibrillation. The LAA is an important source of natriuretic peptides and its exclusion from the circulation may alter the blood level of these hormones, thereby influencing their diagnostic value and clinical effects.
Methods: We aimed to prospectively assess potential changes in mid-regional pro A-type natriuretic peptide (MR-proANP) and N-terminal pro B-type natriuretic peptide (NT-proBNP) levels 6 weeks and 6 months after interventional LAA closure using the WATCHMAN device.
Objective: Despite the advanced therapy with statins, antithrombotics, and antihypertensive agents, the medical treatment of atherosclerotic disease is less than optimal. Therefore, additional therapeutic antiatherosclerotic options are desirable. This pilot study was performed to assess the potential antiatherogenic effect of the peroxisome proliferator-activated receptor-γ agonist pioglitazone in nondiabetic patients.
View Article and Find Full Text PDFDespite the advanced therapy with statins, antithrombotics and antihypertensive agents, the medical treatment of coronary artery disease is less than optimal. Therefore, additional therapeutic anti-atherosclerotic options are desirable. This VH-IVUS study (intravascular ultrasonography with virtual histology) was performed to assess the potential anti-atherogenic effect of the PPARγ agonist pioglitazone in non-diabetic patients.
View Article and Find Full Text PDFBased on an analysis of the Magdeburg Dronedarone Registry data we sought to determine which patients could benefit from dronedarone therapy regarding rhythm control. The study included 191 patients (85 women) aged 63 ± 10 years with a history of paroxysmal or persistent AF and a follow-up of 14 ± 5 months. The total AF recurrence rate was 67% and lone AF was significantly more often associated with AF recurrences than non-lone AF (84% vs.
View Article and Find Full Text PDFObjective: We retrospectively assessed the incidence of hemorrhagic complications associated with pacemaker implantation in patients receiving one or more antiplatelet agents.
Design And Setting: Retrospective multicenter case-control study. Data were collected from three cardiac units in Germany from 2006 to 2010.
Background: Continuous lateral rotation ["Kinetic therapy" (KT)] has been shown to reduce complications and to shorten hospital stay in trauma patients. Data in non-surgical patients is inconclusive. Retrospective data suggest a beneficial effect of KT in patients with cardiogenic shock (CS) requiring ventilator therapy.
View Article and Find Full Text PDFIrregular sensing by triple counting of wide QRS complexes resulted in inappropriate shocks in a patient with a biventricular implantable cardioverter defibrillator (ICD): A 66-year-old male patient with ischemic cardiomyopathy, left bundle branch block, and impaired left ventricular function received a biventricular ICD for optimal therapy of heart failure (CHF). Two years after implantation, the patient experienced recurrent unexpected ICD shocks without clinical symptoms of malignant tachyarrhythmia, or worsened CHF. The patient's condition rapidly worsened, with progressive cardiogenic shock and electrical-mechanical dissociation.
View Article and Find Full Text PDFObjective: Cardiogenic shock is the leading cause of death in patients hospitalized for acute myocardial infarction. The objectives were to investigate the effects of levosimendan, a novel inodilator, compared with the phosphodiesterase-III inhibitor enoximone in refractory cardiogenic shock complicating acute myocardial infarction, on top of current therapy.
Design: Prospective, randomized, controlled single-center clinical trial.
Background: Kinetic therapy (KT) has been shown to reduce complications and to shorten hospital stay in trauma patients. Data in non-surgical patients are inconclusive, and kinetic therapy has not been tested in patients with cardiogenic shock.
Objective: The present analysis compares KT with standard care in patients with cardiogenic shock.