Infections after internal fixation of fractures remain a challenge. Silver is known for its antimicrobial activity, including activity against multi-resistant strains. The aim of the current study was to analyze the biocompatibility and potential influence on the osteotomy healing process of a silver-coating technology for locking plates compared to silver-free locking plates in an established rabbit model.
View Article and Find Full Text PDFIntroduction: The aim of this study was to test the mechanical stability of LOQTEQ® HTO plate in comparison to the TomoFix™ internal plate fixator.
Materials And Methods: An unstable fracture gap model with two standardized polyoxymethylene (POM) cylinders was used for this study. With this model 5 LOQTEQ® HTO plates and 5 TomoFix™ were cyclically loaded.