Publications by authors named "Thomas Maeder"

The application of gas sensors in breath analysis is an important trend in the early diagnostics of different diseases including lung cancer, ulcers, and enteric infection. However, traditional methods of synthesis of metal oxide gas-sensing materials for semiconductor sensors based on wet sol-gel processes give relatively high sensitivity of the gas sensor to changing humidity. The sol-gel process leading to the formation of superficial hydroxyl groups on oxide particles is responsible for the strong response of the sensing material to this factor.

View Article and Find Full Text PDF

A method for determining the critical values of the flow speed and the flow constriction degree characteristic of the alignment of cylindrical nano-objects in a flowing suspension is proposed. Previously, the alignment process of cylindrical nano-objects in suspensions was investigated by using birefringence of the polarized light and the small-angle X-ray scattering. While both methods are suitable for measuring the alignment degree of cylindrical nano-objects in suspensions diluted down to low concentrations, they are restricted for the application to undiluted concentrated suspensions because of non-transparency and multiple scattering of X-rays.

View Article and Find Full Text PDF

With growing public interest in portable electronics such as micro fuel cells, micro gas total analysis systems, and portable medical devices, the need for miniaturized air pumps with minimal electrical power consumption is on the rise. Thus, the development and downsizing of next-generation thermal transpiration gas pumps has been investigated intensively during the last decades. Such a system relies on a mesoporous membrane that generates a thermomolecular pressure gradient under the action of an applied temperature bias.

View Article and Find Full Text PDF

The development of microreactors that operate under harsh conditions is always of great interest for many applications. Here we present a microfabrication process based on low-temperature co-fired ceramic (LTCC) technology for producing microreactors which are able to perform chemical processes at elevated temperature (>400 °C) and against concentrated harsh chemicals such as sodium hydroxide, sulfuric acid and hydrochloric acid. Various micro-scale cavities and/or fluidic channels were successfully fabricated in these microreactors using a set of combined and optimized LTCC manufacturing processes.

View Article and Find Full Text PDF

We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g.

View Article and Find Full Text PDF

We evaluate the percolation threshold values for a realistic model of continuum segregated systems, where random spherical inclusions forbid the percolating objects, modeled by hardcore spherical particles surrounded by penetrable shells, to occupy large regions inside the composite. We find that the percolation threshold is generally a nonmonotonous function of segregation, and that an optimal (i.e.

View Article and Find Full Text PDF

We have developed a robotic interface to train hand and finger function. HandCARE is a Cable-Actuated REhabilitation system, in which each finger is attached to an instrumented cable loop allowing force control and a predominantly linear displacement. The device, whose designed is based on biomechanical measurements, can assist the subject in opening and closing movements and can be adapted to accommodate various hand shapes and finger sizes.

View Article and Find Full Text PDF

Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus-valgus loading.

View Article and Find Full Text PDF

To improve the ligament balancing procedure during total knee arthroplasty a force-sensing device to intraoperatively measure knee joint forces and moments has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate and a set of spaces to adapt the device thickness to the patient-specific tibiofemoral gap. Each sensitive plate is equipped with three deformable bridges instrumented with thick-film piezoresistive sensors, which allow accurate measurements of the amplitude and location of the tibiofemoral contact forces.

View Article and Find Full Text PDF