Purpose: This study reports the impact of using a centralized database system for major equipment quality assurance (QA) at a large institution.
Methods And Materials: A centralized database system has been implemented for radiation therapy machine QA in our institution at 6 campuses with 11 computed tomographies and 22 linear accelerators (LINACs). The database system was customized to manage monthly and annual computed tomography and LINAC QA.
Int J Med Phys Clin Eng Radiat Oncol
August 2021
Managing TG-51 reference dosimetry in a large hospital network can be a challenging task. The objectives of this study are to investigate the effectiveness of using Statistical Process Control (SPC) to manage TG-51 workflow in such a network. All the sites in the network performed the annual reference dosimetry in water according to TG-51.
View Article and Find Full Text PDFPurpose: Real-time tumor tracking through active correction by the multileaf collimator or treatment couch offers a promising strategy to mitigate delivery uncertainty due to intrafractional tumor motion. This study evaluated the performance of MLC and couch tracking using the prototype iTools Tracking system in TrueBeam Developer Mode and the application for abdominal cancer treatments.
Methods: Experiments were carried out using a phantom with embedded Calypso transponders and a motion simulation platform.
Purpose: This study proposes a proactive maintenance model utilizing historical Multileaf collimator (MLC) performance data to predict potential MLC dysfunctions, promote preemptive maintenance and thereby reduce treatment disruptions.
Methods: MLC failures were assumed to correlate with MLC performance quantitation from trajectory logs. A cohort of data from service reports and trajectory logs was used to establish a model for predicting MLC dysfunctions.
Purpose: To present the clinical commissioning of a novel Pd directional brachytherapy device (CivaSheet) for intraoperative radiation therapy.
Methods And Materials: Clinical commissioning for the CivaSheet consisted of establishing: (1) source strength calibration capabilities, (2) experimental verification of TG-43 dosimetry parameters, (3) treatment planning system validation, and (4) departmental practice for dose specification and source ordering. Experimental verification was performed in water with radiochromic film calibrated with a 37 kVp X-ray beam.
Hypofractionated treatments generally increase the complexity of a treatment plan due to the more stringent constraints of normal tissues and target coverage. As a result, treatment plans contain more modulated MLC motions that may require extra efforts for accurate dose calculation. This study explores methods to minimize the differences between in-house dose calculation and actual delivery of hypofractionated volumetric-modulated arc therapy (VMAT), by focusing on arc approximation and tongue-and-groove (TG) modeling.
View Article and Find Full Text PDFPurpose: A novel (32)P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source.
Methods And Materials: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation.
AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
October 2008
Purpose: The Varian RapidArc is a system for intensity-modulated radiotherapy (IMRT) treatment planning and delivery. RapidArc incorporates capabilities such as variable dose-rate, variable gantry speed, and accurate and fast dynamic multileaf collimators (DMLC), to optimize dose conformality, delivery efficiency, accuracy and reliability. We developed RapidArc system commissioning and quality assurance (QA) procedures.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
June 2008
The use of a multileaf collimator (MLC) for intensity-modulated radiotherapy poses unique dosimetric issues. The nature of intensity-modulated radiotherapy dosimetry, centered on leaf position accuracy, is common to all MLCs. However, the mechanical and software designs of MLCs from the different manufacturers distinguish them.
View Article and Find Full Text PDFTG-69 is a task group report of the AAPM on the use of radiographic film for dosimetry. Radiographic films have been used for radiation dosimetry since the discovery of x-rays and have become an integral part of dose verification for both routine quality assurance and for complex treatments such as soft wedges (dynamic and virtual), intensity modulated radiation therapy (IMRT), image guided radiation therapy (IGRT), and small field dosimetry like stereotactic radiosurgery. Film is convenient to use, spatially accurate, and provides a permanent record of the integrated two dimensional dose distributions.
View Article and Find Full Text PDFThe higher sensitivity to low-energy scattered photons of radiographic film compared to water can lead to significant dosimetric error when the beam quality varies significantly within a field. Correcting for this artifact will provide greater accuracy for intensity modulated radiation therapy (IMRT) verification dosimetry. A procedure is developed for correction of the film energy-dependent response by creating a pencil beam kernel within our treatment planning system to model the film response specifically.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
September 2006
Purpose: Postmastectomy radiation therapy (PMRT) is often delivered to patients with permanent breast implants. On occasion, patients are irradiated with a tissue expander (TE) in place before their permanent implant exchange. Because of concern of potential under-dosing in these patients, we examined the dosimetric effects of the Magna-Site (Santa Barbara, CA) metallic port that is present in certain TEs.
View Article and Find Full Text PDFThe energy dependence of radiographic film can introduce dosimetric errors when evaluating photon beams. The variation of the film response, which is attributed to the changing photon spectrum with depth and field size, has been the subject of numerous publications in recent years. However, these data show large unexplained differences in the magnitude of this variation among independent studies.
View Article and Find Full Text PDFThe advantage of radiographic film is that it allows two-dimensional, high-resolution dose measurement. While there is concern over its photon energy dependence, these problems are considered acceptable within small fields, where the scatter component is small. The application of film dosimetry to intensity modulated radiotherapy (IMRT) raises additional concern since the primary fluence may vary significantly within the field.
View Article and Find Full Text PDFIntensity-modulated radiotherapy represents a recent advancement in conformal radiotherapy. It employs specialized computer-driven technology to generate dose distributions that conform to tumor targets with extremely high precision. Treatment planning is based on inverse planning algorithms and iterative computer-driven optimization to generate treatment fields with varying intensities across the beam section.
View Article and Find Full Text PDF