Cross-linked bearings have been developed for use in total knee arthroplasty that exhibit improved wear properties, but at the expense of a decrease in mechanical strength of the cross-linked material. Adoption has been slow due to fears of mechanical failure secondary to this alteration in mechanical properties. This prospective, randomized study compared mid-term survivorship, clinical and radiographic results of a conventional polyethylene (GVF) to a cross-linked polyethylene (XLK) in total knee prostheses of the same design.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
May 2013
Bone tissue and geometry are constantly modified through modeling and remodeling at the periosteal, endosteal and intracortical envelopes. Results from several studies indicate that femoral bone geometry is a predictor of whole bone strength (e.g.
View Article and Find Full Text PDFBackground: Implant-related impingement has been reported following metal-on-metal hip resurfacing, and reactive osseous patterns associated with implant-bone impingement have been identified. The purpose of this study was to determine the prevalence and clinical implications of radiographic signs of femoral neck-acetabular cup impingement following metal-on-metal hip resurfacing.
Methods: Serial anteroposterior and lateral radiographs made five to 12.
This study reports minimum 5-year results of 95 hips implanted with a Pinnacle (DePuy, Warsaw, Ind) modular metal-on-metal acetabular prosthesis. Clinical scores such as the Harris Hip and Western Ontario and McMaster Universities Arthritis Index revealed excellent clinical outcomes at mean 6-year follow-up. With the use of large-diameter femoral heads, dislocation was rare, occurring in only 1 hip.
View Article and Find Full Text PDFBackground: There was a need for information about the long-term performance of the modern generation of hip resurfacing implants. A retrospective review of the first 100 hips that had implantation of one resurfacing design and had been followed for a minimum of ten years was performed.
Methods: Between 1996 and 1998, 100 CONSERVE PLUS hip resurfacing devices were implanted by a single surgeon in eighty-nine patients.
Our goal was to determine the 7-year survivorship of a total knee arthroplasty system with all-polyethylene tibial components. From June 1996 to December 1997, 129 consecutive patients (177 knees) (>/=70 years old) underwent such primary arthroplasty at 2 centers in the United States. The 88 patients (120 knees) with 7 years or more of follow-up were evaluated radiographically and functionally.
View Article and Find Full Text PDFWe prospectively studied 207 consecutive patients (284 knees) undergoing total knee arthroplasty (June 1996 to December 1997) with a cemented tricompartmental Sigma PFC (DePuy Orthopaedics, Warsaw, Ind) total knee arthroplasty via a standard procedure (median follow-up, 87 months). Cruciate-retaining (272 knees, 96%) and cruciate-substituting (12, 4%) implants were used. There was one revision secondary to a ligament disruption after a fall.
View Article and Find Full Text PDFUnlabelled: We compared the incidence of wear-related failures between two large cohorts of patients undergoing total knee arthroplasty implanted with identical modular tibial trays and polyethylene inserts sterilized by different methods. A total of 1183 second-generation press-fit condylar prostheses having inserts packaged and sterilized in an oxygen-free environment were assessed at a minimum 5-year followup (mean, 7.0 years).
View Article and Find Full Text PDFBackground: Following the reintroduction of metal-on-metal articulating surfaces for total hip arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using a metal-on-metal articulation. The present study describes the clinical and radiographic results of the first 400 hips treated with metal-on-metal hybrid surface arthroplasties at an average follow-up of three and a half years.
Methods: Between November 1996 and November 2000, 400 metal-on-metal hybrid surface arthroplasties were performed in 355 patients.
Long-term survival of the acetabular component in revision total hip arthroplasty (THA) is determined by initial implant stability and bone ingrowth. Highly porous Trabecular Metal (TM, Zimmer, Inc, Warsaw, Ind) facilitates ingrowth and may be an ideal material for revision THA. The outcome and survivorship of a TM, nonmodular, uncemented acetabular cup were assessed in 60 consecutive patients undergoing revision THA (mean follow-up, 42 months; range, 14-68 months).
View Article and Find Full Text PDFThis article presents an empirical test of organizational identification in the context of customer-company (C-C) relationships. It investigates whether customers identify with companies and what the antecedents and consequences of such identification are. The model posits that perceived company characteristics, construed external image, and the perception of the company's boundary-spanning agent lead to C-C identification.
View Article and Find Full Text PDFSerial radiographs of a porous tantalum monoblock acetabular cup design were evaluated for cup stability and signs of successful osteointegration. Of 574 primary consecutive total hip replacements in 542 patients performed by 9 surgeons at 7 hospitals, 414 cases were available for minimum 2-year follow-up. Follow-up averaged 33 months and ranged from 24 to 58 months.
View Article and Find Full Text PDFClin Orthop Relat Res
January 2004
We evaluated radiologic and clinical features affecting the outcome of hybrid metal-on-metal surface arthroplasty of the hip in 119 hips in patients 40 years and younger. Only the hips that had either failed or had minimum 2-year followup were reviewed. Ninety-four hips in 83 patients with a mean age of 34.
View Article and Find Full Text PDFBackground: Following the reintroduction of metal-on-metal articulating surfaces for total hip arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using a metal-on-metal articulation. The present study describes the clinical and radiographic results of the first 400 hips treated with metal-on-metal hybrid surface arthroplasties at an average follow-up of three and a half years.
Methods: Between November 1996 and November 2000, 400 metal-on-metal hybrid surface arthroplasties were performed in 355 patients.
Measurements were made from annual follow-up radiographs, obtained over 27.6 years, of 860 cemented total hip arthroplasties implanted by one surgeon. Femoral components were made of stainless steel or titanium alloy, were non-modular, and were all fixed with cement, and acetabular cups were all-polyethylene and were fixed with cement.
View Article and Find Full Text PDFShort and long duration tests were conducted on hollow femoral bone cylinders to study the circumferential (hoop) creep response of cortical bone subjected to an intramedullary radial load. It was hypothesized that there is a stress threshold above which nonlinear creep effects dominate the mechanical response and below which the response is primarily determined by linear viscoelastic material properties. The results indicate that a hoop stress threshold exists for cortical bone, where creep strain, creep strain rate and residual strain exhibited linear behavior at low hoop stress and nonlinear behavior above the hoop stress threshold.
View Article and Find Full Text PDF