A method for the determination of longitudinal and transverse bulk acoustic wave attenuation from measurements of the decay-rate of two independent zero-group-velocity resonances in a couple of matched plates is presented. A linear relation is derived, which links the bulk-wave attenuation coefficients to the decay-rate of plate-resonances. The relation is used to determine the acoustic loss of tungsten at GHz frequencies from noncontact laser-ultrasonic measurements in plates with thicknesses of about 1 µm.

View Article and Find Full Text PDF

In conventional photoacoustic tomography, several effects contribute to the loss of resolution, such as the limited bandwidth and the finite size of the transducer, or the space-dependent speed of sound. They can all be compensated (in principle) technically or numerically. Frequency-dependent acoustic attenuation also limits spatial resolution by reducing the bandwidth of the photoacoustic signal, which can be numerically compensated only up to a theoretical limit given by thermodynamics.

View Article and Find Full Text PDF

Chemical mapping was demonstrated with a mid-infrared (MIR) microspectroscopy setup based on a supercontinuum source (SC) emitting in the spectral range from 1.55 to 4.5 µm and a MEMS-based Fabry-Pérot filter spectrometer.

View Article and Find Full Text PDF

In this Letter, we theoretically describe photoacoustic signal generation of molecules, for which triplet relaxation can be neglected, by considering the excited state lifetime, the fluorescence quantum yield, and the fast vibrational relaxation. We show that the phase response of the photoacoustic signal can be exploited to determine the excited state lifetime of dark molecules. For fluorescent molecules, the phase response can be used to determine the fluorescence quantum yield directly without the need of reference samples.

View Article and Find Full Text PDF

Compressed sensing (CS) is a promising approach to reduce the number of measurements in photoacoustic tomography (PAT) while preserving high spatial resolution. This allows to increase the measurement speed and reduce system costs. Instead of collecting point-wise measurements, in CS one uses various combinations of pressure values at different sensor locations.

View Article and Find Full Text PDF

We introduce all-optical photoacoustic projection imaging. An array of fiber-optic interferometers is used to measure photoacoustic signals. The obtained images represent the projection of the three-dimensional spatial light absorbance within a sample onto a two-dimensional plane.

View Article and Find Full Text PDF

We report on a novel imaging system for large depth of field photoacoustic scanning macroscopy. Instead of commonly used piezoelectric transducers, fiber-optic based ultrasound detection is applied. The optical fibers are shaped into rings and mainly receive ultrasonic signals stemming from the ring symmetry axes.

View Article and Find Full Text PDF

We report on simultaneous frequency domain optical-resolution photoacoustic and fluorescence microscopy with sub-µm lateral resolution. With the help of a blood smear, we show that photoacoustic and fluorescence images provide complementary information. Furthermore, we compare theoretically predicted signal-to-noise ratios of sinusoidal modulation in frequency domain with pulsed excitation in time domain.

View Article and Find Full Text PDF

In the presented work, the characterization of plates using zero group velocity Lamb modes is discussed. First, analytical expressions are shown for the determination of the k-ω location of the zero group velocity Lamb modes as a function of the Poisson's ratio. The analytical expressions are solved numerically and an inverse problem is formulated to determine the unknown wave velocities in plates of known thickness.

View Article and Find Full Text PDF

We demonstrate non-contact remote photoacoustic spectroscopy in the mid-infrared region. A room-temperature-operated pulsed external-cavity quantum cascade laser is used to excite photoacoustic waves within a semitransparent sample. The ultrasonic waves are detected remotely on the opposite side of the sample using a fiber-optic Mach-Zehnder interferometer, thereby avoiding problems associated with acoustic attenuation in air.

View Article and Find Full Text PDF

We present multimodal noncontact photoacoustic (PA) and optical coherence tomography (OCT) imaging. PA signals are acquired remotely on the surface of a specimen with a Mach-Zehnder interferometer. The interferometer is realized in a fiber-optic network using a fiber laser at 1550 nm as the source.

View Article and Find Full Text PDF

We developed a multimodal imaging system, combining noncontact photoacoustic imaging and optical coherence tomography (OCT). Photoacoustic signals are recorded without contact to the specimens' surface by using an interferometric technique. The interferometer is realized within a fiber-optic network using a fiber laser at 1550 nm as source.

View Article and Find Full Text PDF

In this study a theoretical framework for calculating the acoustic response of optical fiber-based ultrasound sensors is presented. The acoustic response is evaluated for optical fibers with several layers of coating assuming a harmonic point source with arbitrary position and frequency. First, the fiber is acoustically modeled by a layered cylinder on which spherical waves are impinged.

View Article and Find Full Text PDF

Most reconstruction algorithms for photoacoustic tomography, like back projection or time reversal, work ideally for point-like detectors. For real detectors, which integrate the pressure over their finite size, images reconstructed by these algorithms show some blurring. Iterative reconstruction algorithms using an imaging matrix can take the finite size of real detectors directly into account, but the numerical effort is significantly higher compared to the use of direct algorithms.

View Article and Find Full Text PDF

We present an improved detection scheme for a two-wave mixing interferometer with a BiSiO crystal. The proposed detection scheme allows quasi-balanced detection of ultrasonic signals whereby electrical disturbances are suppressed. Quasi-balancing is achieved by changing the polarity of the high voltage at the photorefractive crystal, leading to an inversion of the optical interference signal, in combination with inversion of the detector signal using a signal inverter before the data acquisition device.

View Article and Find Full Text PDF

In photoacoustic imaging the ultrasonic signals are usually detected by contacting transducers. For some applications contact with the tissue should be avoided. As alternatives to contacting transducers interferometric means can be used to acquire photoacoustic signals remotely.

View Article and Find Full Text PDF

This article elaborates on the crossing points of the frequency-wavenumber branches for the symmetric and anti-symmetric Lamb modes in a homogeneous plate. It is shown both theoretically as well as experimentally that at these crossing points either the normal or the longitudinal components of modal displacement attain an extreme value, i.e.

View Article and Find Full Text PDF

In the present paper we demonstrate the possibility to image dyed solids, i.e. Rhodamine B dyed polyethylene spheres, by means of two-photon absorption-induced photoacoustic scanning microscopy.

View Article and Find Full Text PDF

Beam profiles are commonly measured with complementary metal oxide semiconductors (CMOS) or charge coupled devices (CCD). The devices are fast and reliable but expensive. By making use of the fact that the Bayer-filter in commercial webcams is transparent in the near infra-red (>800 nm) and their CCD chips are sensitive up to about 1100 nm, we demonstrate a cheap and simple way to measure laser beam profiles with a resolution down to around ±1 μm, which is close to the resolution of the knife-edge technique.

View Article and Find Full Text PDF

The ongoing expansion of the frequency range used for ultrasonic imaging requires increasing attention to the acoustic attenuation of biomaterials. This work presents a novel method for measuring the attenuation of tissue and liquids in vitro on the basis of single transmission measurements. Ultrasound was generated by short laser pulses directed onto a silicon wafer.

View Article and Find Full Text PDF

Laser-generation of ultrasound is investigated in the coupled dynamical thermoelasticity in the presented paper. The coupled heat conduction and wave equations are solved using finite differences. It is shown that the application of staggered grids in combination with explicit integration of the wave equation facilitates the decoupling of the solution and enables the application of a combination of implicit and explicit numerical integration techniques.

View Article and Find Full Text PDF

The frequency response of fiber optic line detectors is investigated in the presented paper. An analytical model based on oblique scattering of elastic waves is used to calculate the frequency dependent acousto-optical transfer functions of bare glass optical and polymer optical fibers. From the transfer functions the transient response of fibers detectors to photoacoustically excited spherical sources is derived.

View Article and Find Full Text PDF

In this paper we report on remote three-dimensional photoacoustic imaging without the need for a coupling agent or other aids (e.g. detector foils) by utilizing a two-wave mixing interferometer (TWMI).

View Article and Find Full Text PDF

We report on remote and contactless photoacoustic imaging (PAI) for the inspection of solid materials using a two-wave mixing interferometer. In this Letter, a semitransparent sample was excited with picosecond laser pulses. The local absorption of the electromagnetic radiation led to generation of broadband ultrasonic waves inside the sample.

View Article and Find Full Text PDF

For photoacoustic imaging, usually point-like detectors are used. As a special sensing technology for photoacoustic imaging, integrating detectors have been investigated that integrate the acoustic pressure over an area or line that is larger than the imaged object. Different kinds of optical fiber-based detectors are compared regarding their sensitivity and resolution in three-dimensional photoacoustic tomography.

View Article and Find Full Text PDF